Sir,
We allude to the interesting article titled, 'Intracranial translucency as a sonographic marker for detecting open spina bifida at 11–13+6 weeks scan: Our experience by Teegala et al.[1] The authors have clearly illustrated the significance of the obliteration of intracranial translucency (IT) as a marker for open spinal dysraphism (OSD) in the first trimester. Evaluation of the mid-sagittal plane of the fetal face is an integral part of every first trimester scan between 11 and 13+6 weeks. As the time spent on each scan is an important consideration in clinical practice, evaluation of IT in the same mid-sagittal plane gives a rich dividend of early detection of an OSD at no extra cost of time. However, there are instances when IT is difficult to assess, as is the case in this study as well.
In a recent study, Ramkrishna et al. proposed a novel marker for detection of OSD in the first trimester, namely the maxillo-occipital line in the mid-sagittal plane.[2] The maxillo-occipital line is a straight line drawn along the superior border of the maxilla that touches the occipital bone posteriorly. The authors observed that the junction of the thalamus with the midbrain was above this maxillo-occipital line in normal fetuses and below this line in the fetuses with open spina bifida. This can be attributed to the descent of the brainstem in open spina bifida due to the egress of the cerebrospinal fluid through the spinal defect. The observation is illustrated in a normal fetus [Figure 1] and a fetus with lumbosacral myeloschisis [Figure 2]. These findings are also evident in the cases shown in the article by Teegala ML et al. Assessment of the case in this study in which the IT was not clear using the maxillo-occipital line may be enlightening.
In conclusion, obliteration of IT (fourth ventricle) is a strong marker for OSD in the first trimester. The novel marker, namely the maxillo-occipital line, which is a pointer of brainstem descent in OSD may aid in enhancing the operator's degree of confidence in case IT is not clear. Although the mid-sagittal section of the fetal face made its debut on the runway more than two decades ago to measure nuchal translucency, it continues to be a showstopper revealing new sonographic markers of fetal anomalies.
#
Conflict of Interest
There are no conflicts of interest.
-
References
- 1 Teegala ML, Vinayak DG. Intracranial translucency as a sonographic marker for detecting open spina bifida at 11–13+6 weeks scan: Our experience. Indian J Radiol Imaging 2017; 27: 427-31
- 2 Ramkrishna J, Araujo EJunior, White N, da Silva FCosta, Meagher S. P09.11: Maxillo-occipital line: A sonographic marker for the screening of open spina bifida in the first trimester. Ultrasound Obstet Gynecol 2017; 50: 184
Address for correspondence
Publication History
Article published online:
26 July 2021
© 2018. Indian Radiological Association. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/).
Thieme Medical and Scientific Publishers Pvt. Ltd.
A-12, 2nd Floor, Sector 2, Noida-201301 UP, India
-
References
- 1 Teegala ML, Vinayak DG. Intracranial translucency as a sonographic marker for detecting open spina bifida at 11–13+6 weeks scan: Our experience. Indian J Radiol Imaging 2017; 27: 427-31
- 2 Ramkrishna J, Araujo EJunior, White N, da Silva FCosta, Meagher S. P09.11: Maxillo-occipital line: A sonographic marker for the screening of open spina bifida in the first trimester. Ultrasound Obstet Gynecol 2017; 50: 184