Keywords
Breast cancer - patent blue dye - sentinel lymph node - single photon emission computed
tomography sentinel lymphoscintigraphy
Introduction
Breast cancer is the most common malignancy in females worldwide and the principal
cause of morbidity and mortality in developing countries.[1] Pakistan has the highest incidence of breast cancer among Asian countries, and five
years' disease-free survival in early stage (I and II) breast cancer is 85% as compared
to 10% in stage IV cases.[2] The axillary nodal disease is the most trivial prognostic factor for early stage
breast cancer patients. Currently, sentinel lymph node biopsy (SLNBx) has evolved
to be a standard practice for axillary staging in early breast cancer.[3],[4] The risks of lymphedema, restricted limb mobility, and neurological deficit are
less in SLNBx as compared to axillary nodal dissection (ALND) as reinforced by Bromham
et al. who found that of every 1000 patients receiving ALND, 132 would suffer from
lymphedema postsurgically, compared with 22–115 of those receiving SLNBx.[5] The advancement of SLNBx has significantly improved the indisposition of surgical
treatment since fewer axillary nodes are dissected. Successful mapping of SLNs in
breast cancer patients depends on the success of the radionuclide lymphoscintigraphy
(LS) employed preoperatively in breast cancer patients.[6] ALND could then be reserved for patients with positive SLN on immunohistochemistry
or in whom the SLN detection failed.[7]
The other method for SLN mapping using patent blue dye (PBD) is being practiced widely
in developing countries. However, the accuracy of PBD alone for SLN mapping in breast
cancer has not been well understood. Giuliano et al. conducted intraoperative lymphatic
mapping using PBD alone.[8] Albertini et al. was the first to identify the SLN using a combined PBD and radioisotope
techniques,[9] although the combined technique is supposed to be more consistent and is currently
the most widely used method for SLN mapping in breast cancer. Recently, several studies
supported that PBD alone was sufficient for detecting SLNs in breast cancer on account
of its practicability and easy availability.[10],[11],[12]
Objectives
The aim of this study was to evaluate the detection efficacy of sentinel mapping using
radionuclide single photon emission computed tomography lymphoscintigraphy (SPECT-CT
LS) followed by gamma probe detection (GPD) and the PBD technique for surgical planning
of breast cancer patients. Second, this study aims to determine which modality is
better for SLN detection.
Materials and Methods
Patient selection criteria
After getting ethical clearance from institutional ethical committee, 1028 early stage
breast cancer cases referred from surgical oncology department of study center for
sentinel LS between 2015 and 2017 were scrutinized. Patients with clinical evidence
of axillary metastases, previous axillary dissection, locally advanced disease, treatment
with neoadjuvant chemoradiotherapy, and pregnancy or lactation were excluded. Cases
with clear visualization of SLN on planar scintigraphy (PS) were also excluded from
analysis. Early stage breast cancers T1 (tumor <2 cm), T2 (tumor size 2–5 cm), and
carcinoma in situ were enrolled in the study retrospectively. Of total referred cases,
134 patients (13%) who met the criteria for SPECT-CT with negative/equivocal/unusual
location of tracer on initial planar scintigraphy[13] were included as depicted in [Figure 1]. Informed consent was taken from all the included patients. Exemption of ethical
approval was granted by the institutional review board vide their letter number EXMPT-26-11-18-02
dated 14.12.2018.
Figure 1 Results of study cases with inclusion criteria based on Planar Lymphoscintigraphy
results who subsequently underwent single photon emission computed tomography and
patent blue dye technique for sentinel mapping
Preoperative single photon emission computed tomography lymphoscintigraphy technique
Radionuclide imaging was performed a day before (within 18 h) surgery or on the day
of surgery. 37–40 MBq of technetium-99 m-labeled human serum albumin colloid particles
(99m Tc-HSA) in a volume of 0.2 ml was injected into two intradermal periareolar locations
at 6 o'clock and 12 o'clock. Patients were selected for SPECT-CT LS on the basis of
non-visualization or equivocal uptakes on planar imaging and imaged using a dual-head
gamma camera with a low-energy, high-resolution, and parallel-hole collimator. The
patient's ipsilateral arm was raised above the head. 16-slice spiral CT scanner was
optimized for rapid rotation. SPECT acquisition (matrix 128 × 128, 60 frames at 25
s per view) was performed using steps of 6 degrees. For CT (130 kV, 20 mA, and B60s
kernel), 5-mm slices were created.
The iterative reconstruction (OSEM 3D) was used for generating SPECT slices. The SPECT
data were corrected for attenuation and scatter and fused with the CT data using software
Syngo package. Maximum intensity projections with a three-dimensional display were
generated to localize sentinel nodes in relation to anatomic structures.
Image analysis
Image analysis was performed by two experienced nuclear physicians in consensus reading.
SPECT-CT findings were classified as either negative SLN if no tracer uptake was detected
in axillary or parasternal region and positive SLN if tracer uptake superimposed on
underlying nodal structure on CT component was detected in axillary or intrathoracic
location. The axillary nodal levels were stratified in relation to their anatomical
location as level I, II, III or internal mammary chain (IMC). SPECT-CT LS images of
one of the study cases are shown in [Figure 2].
Figure 2 Single photon emission computed tomography lymphoscintigraphy images (left side -
axial; middle - sagittal; right - coronal) of a 45 years old female localizing tracer
uptake in right level I axillary sentinel lymph node (marked white arrows) where planar
scintigraphy results were negative
Gamma probe counts' detection
The gamma rays detecting probe was a Scinti-Probe, and radioactivity detected by this
probe was transduced into digital readout and acoustic signals. The intensity and
frequency of the acoustic signal were directly proportional to the level of radioactivity.
This probe was used preoperatively in the operating theater to confirm the skin projection
of SLN seen on scintigraphy as well as peroperative detection of radioactivity in
blue-stained nodes.
Lymphatic mapping with patent blue dye technique
The PBD in a dose of one ml divided in four aliquots of 0.25 ml was injected in the
subdermal region in periareolar location, using a 25-gauge needle, 10–15 min preoperatively.
A gentle massage was followed for 5 min at injection site.
Sentinel lymph node biopsy
Intraoperatively, the gamma probe was used to confirm the location of the SLN. The
skin was incised directly over this point, and the node emitting the highest activity
with activity at least ten times the background level, and/or visually blue stained,
was excised. Sometimes two or more nodes were picked up, irrespective of the status
of the blue dye. Once removed, however, each node was rechecked by the probe, and
the node with the highest count rate was labeled as the SLN. The removed nodes were
classified as blue dye positive, radiocolloid positive, or both.
All harvested nodes were fixed in formalin, bisected, embedded in paraffin and histopathologically
evaluated for the presence or absence of metastasis. The surgeon removed all detected
SLNs (excluding IMC nodes which are not routinely harvested). If frozen section analysis
revealed metastatic SLN, ALND was performed subsequently. The cases with false-negative
SLNs by both techniques also underwent ALND, and metastasis was confirmed histologically.
Statistical analysis
All data were entered and assessed using computer-based Statistical Package for Social
Sciences (SPSS 20, IBM, Armonk, NY, USA). The mean ± SD was calculated for quantitative
variables. Qualitative variables such as tumor histology and detection of SLNs by
SPECT-CT, gamma probe counts detection (GP-CD), and PBD were presented in the form
of percentages and frequencies. The K coefficient of Cohen's was used to determine
the strength of agreement between radionuclide mapping and PBD technique. Poststratification,
Chi-square test was applied. P ≤ 0.05 was taken as statistically significant.
Results
One hundred and thirty-four breast cancer cases fulfilling the inclusion and exclusion
criteria underwent SPECT-CT LS followed by peroperative hand-held sentinel lymph node
gamma probe count detector (Europrobe 3) and patent blue dye technique. All cases
were females. Patients' demographic data, general and histopathological findings of
their primary breast tumor are given in [Table 1].
Table 1 Demographics of study population, general and histological features of their breast
cancer
The sentinel nodes were identified in 105/134 cases by SPECT-CT LS (success rate of
78.4%) and failed in 29/134 cases; later, GP-CD detected hot nodes in additional 20
cases (detection rate of 93.3%). No equivocal uptake was seen on SPECT-CT LS. The
PBD successfully localized SLN in 131/134 (97.8%) of the cases. In six of nine with
no detectable radioactivity in the axilla, SLNs were identified only by PBD staining
while none of the cases was identified only by isotopic detection (hot only), illustrating
failure rates of 2.2%(3/134) and 6.7%(9/134), respectively, as shown in [Figure 3]. Therefore, the contribution of PBD to metastatic nodes' identification was relevant
for 4.5% (6/134) patients. None of the cases developed allergic reaction with PBD.
Figure 3 Bar chart representation of results relating sentinel lymph node detection by single
photon emission computed tomography lymphoscintigraphy, Peroperative gamma probe count
detection and patent blue dye technique
Three cases remained negative on both radioisotope and PBD localization. On subsequent
axillary nodal dissection, all had metastatic nodal disease. All SLNs detected on
SPECT-CT showed blue dye uptake. In 112 cases, more than one SLN was surgically removed.
Nonsentinel nodes that were “blue-stained”only with minimal background radioactivity
were removed as well. A total of 336 excised blue stained ± hot nodes underwent frozen
section analysis and metastatic disease was seen in 31%. The histopathological results
of bisected SLNs detected by both techniques are shown in [Table 2].
Table 2 Histopathological findings of harvested sentinel lymph nodes by radionuclide mapping
and blue dye technique
Overall moderate agreement (k = 0.56) was calculated between isotope detection and
PBD. No statistically significant difference was noted in SLN mapping between isotope
and PBD technique.
Discussion
According to practical guidelines of American Society of Breast Surgeons,[14] SLNBx is a well-established standard of care for nodal staging in breast cancer.
The ultimate goal of SLNBx is to take away sufficient “hot”and/or blue nodes and/or
clinically palpably suspicious nodes for staging axilla. Regarding radioactivity,
the objective should be to remove the “hottest”SLN, and most of the surgeons eradicate
all nodes whose counts are 10% or more of the hottest node (“10% rule”). Regarding
blue dye, one should aim to remove blue nodes or neighboring nodes with blue-stained
lymphatics.
PBD technique for SLN detection was first reported by Morton et al. in 1992,[15] while Krag et al.[4] accustomed the use of radioisotopes for SLN mapping in 1993. Later, several studies[16],[17] emphasized role of combined technique but no single method has been standardized
till date. It all depends on availability, expertise, and resources of the various
institutes of developing countries.
In the current study, SLN was successfully localized by SPECT-CT imaging followed
by GP-CD in 125/134 cases. The technique failed in nine cases; in six of which, PBD
revealed blue-stained SLN which showed metastases on histological examination. It
has been emphasized in literature that false-negative results are found when SLN are
heavily infiltrated with metastases or when there is a technical failure due to the
relatively large size of nanocolloid particles leading to clumping and failed entry
into lymphatics.[18] This fact is also supported by our study as three false-negative cases by both radionuclide
and PBD technique who subsequently underwent ALND were found to be metastatic by histopathological
analysis.
There are various studies that emphasized role of blue dye technique in SLN mapping.
In a recent meta-analysis and literature search conducted by Jiyu Li et al., it was
concluded that false-negative rate is higher when using blue dye as a sole sentinel
mapping tool.[19] In the developing countries, apart from the cost of nanocolloid used for sentinel
mapping, radiation burden has also remained a major concern, but various studies in
this regard have concluded it to be safe even for pregnant patients and surgeons.[20],[21] Several studies reported that blue dye alone was appropriate for identifying SNs
in breast cancer.[12] In our study, PBD detected SLNs in six cases that were false-negative by radionuclide
technique, while all those cases positive by SPECT-CT and/or GP-CD method were blue
stained as well. Hence, in these cases, addition of PBD had no significant added benefit.
Moreover, none of the cases with PBD had false-negative SLNs, depicting that even
blue dye is sufficient as a sole method of mapping where radionuclide method is not
feasible. There are many studies in favor of blue dye technique as the single best
choice for practice.[12],[22] Hence, our study emphasized that sentinel mapping using SPECT-CT LS followed by
GP-CD could give sufficient information regarding SLN detection, can obviate the need
for PBD technique, and serve as a cost-effective method as blue dye role is limited
due to its adverse effects mainly but not limited to allergic reactions.
There are various types of blue dye depending on their molecular configuration and
characteristics. The most common blue dyes used in SLNBx are isosulfan blue (ISB)
and patent blue (PBD). Methylene blue dye (MBD), relatively cheap, not associated
with potential life-threatening allergic reactions, is also used to map SLNs in most
of the developing countries despite milder form of skin reactions in the form of fat
necrosis.[23] Several studies have demonstrated that MBD can serve as an alternative to ISB and
PBD for SN mapping.[24],[25],[26] In our setup, we used PBD and have no reported case of allergic reaction secondary
to its usage, although there are cases published in literature documenting skin allergies
and necrosis with use of PBD.[27] Another limitation with use of blue dye method is its association with jejunal atresia
during the first trimester of pregnant breast cancer patients.[28] In contrary, radiation dose delivered to the abdomen during radionuclide LS is less
than the average background radiation dose of 8.2 mGy per day with no reported adverse
effects to fetus.[29]
Limitations of study
As it has been stated earlier, only cases who were negative or equivocal on planar
LS were included while those with clear visualization on planar imaging were excluded
from analysis which may have contributed to study bias. Moreover, our study was aimed
to specifically evaluate only those difficult cases where we needed hybrid SPECT-CT
LS and compared its results with PBD technique.
Conclusion
Radionuclide sentinel mapping has good detection rate particularly combined with gamma
probe-guided intraoperative sentinel biopsy, obviating the need for dual mapping.
PBD had added value to reduce the false-negative rate of radionuclide method.
Practice can be limited to sole mapping technique using hybrid/SPECT-CT sentinel mapping,
and PBD can be restricted to those cases who were negative on radionuclide mapping.
Declaration of patient consent
The authors certify that they have obtained all appropriate patient consent forms.
In the form, the patients have given their consent for their images and other clinical
information to be reported in the journal. The patients understand that their names
and initials will not be published and due efforts will be made to conceal their identity,
but anonymity cannot be guaranteed.