Abstract
Background and study aims Carbon dioxide (CO2) is being increasingly used for insufflation during endoscopy for safety and better tolerance. The role of CO2 during endoscopic ultrasonography (EUS) has not been studied yet. Our main aim was to compare the effects of CO2 vs. air insufflation on abdominal discomfort in patients undergoing EUS. Our secondary outcomes were to ascertain the effects of CO2 insufflation on image quality/visual artifacts and on the amount of sedation.
Patients and methods This was a prospective, controlled, single-blind, observational study. Abdominal discomfort was assessed before diagnostic EUS, and 1 and 3 hours post-procedure and recorded as a visual analogue scale. Image quality was also recorded as a 4-point scale from optimal to poor at four different scanning sites (esophagus, stomach, duodenal bulb and second portion).
Results A total of 198 patients were enrolled. We observed that CO2 resulted in less abdominal discomfort than air insufflation that was statistically significant at 3 hours (P = 0.048) but not at 1 hour after EUS (P = 0.112), probably due to the ongoing effects of sedation at the latter stage. On the other hand, no differences were found in the dose of sedation administered in the two groups. Image quality was significantly better in the CO2 group compared to the air group at all four different scanning sites (P < 0.01). Similarly, CO2 correlated with less visual artifacts and need of suction (P < 0.01).
Conclusions Similarly to previous findings with other endoscopic procedures, EUS was associated with improved scores for abdominal discomfort with CO2 rather than air insufflation. Moreover, overall EUS image quality was improved using CO2 insufflation. Future studies are warranted to ascertain whether CO2 insufflation should be regarded as the standard of care for diagnostic EUS.
-
References
- 1 Wu J, Hu B. The role of carbon dioxide insufflation in colonoscopy: a systematic review and meta-analysis. Endoscopy 2012; 44: 128-36
- 2 Saltzman HA, Sieker HO. Intestinal response to changing gaseous environments: normobaric and Hyperbaric observations. Ann N Y Acad Sci 1968; 150: 31-39
- 3 Li X, Zhao YJ, Dai J. et al. Carbon dioxide insufflation improves the intubation depth and total enteroscopy rate in single-balloon enteroscopy: a randomized, controlled, double-blind trial. Gut 2014; 63: 1560-1565
- 4 Bretthauer M, Seip B, Aasen S. et al. Carbon dioxide insufflation for more comfortable endoscopic retrograde cholangiopancreatography: a randomized, controlled, double-blind trial. Endoscopy 2007; 39: 58-64
- 5 Lee SJ, Lee TH, Park SH. et al. Efficacy of carbon dioxide versus air insufflation according to different sedation protocols during therapeutic endoscopic retrograde cholangiopancreatography: Prospective, randomized, double-blind study. Digestive Endoscopy 2015; 27: 512-521
- 6 Aquino JCM, Bernardo WM, Hourneaux de Moura DT. et al. Carbon dioxide versus air insufflation enteroscopy: a systematic review and meta-analysis based on randomized controlled trials. Endosc Int Open 2018; 06: E637-E645
- 7 Serrani M, Calvanese C, Lisotti A. et al. Basics in endoscopic ultrasound part 1: diagnostic indications and tissue sampling. Rev Recent Clin Trials 2017; [Epub ahead of print]
- 8 Serrani M, Calvanese C, Lisotti A. et al. Basics in endoscopic ultrasound part 2: EUS-guided sampling and therapeutic applications. Rev Recent Clin Trials 2017; [Epub ahead of print]
- 9 El Hajj II, Eloubeidi M. Sampling para-aortic lymph nodes in pancreatic and biliary cancers with EUS-guided FNA: diagnostic, clinical, and therapeutic implications. Gastrointest Endosc 2016; 84: 476-478
- 10 Dietrich CF, Burmester E. Contrast-enhanced ultrasound of small focal solid pancreatic lesions: A must!. Endosc Ultrasound 2017; 6: S106-S110
- 11 Varadarajulu S, Wallace MB. Applications of endoscopic ultrasonography in pancreatic cancer. Cancer Control 2004; 11: 15-22
- 12 Bretthauer M, Lynge AB, Thiis-Evensen E. et al. Carbon dioxide insufflation in colonoscopy: safe and effective in sedated patients. Endoscopy 2005; 37: 706-709
- 13 Wu J, Hu B. The role of carbon dioxide insufflation in colonoscopy: a systematic review and meta-analysis. Endoscopy 2012; 44: 128-136
- 14 Bretthauer M, Seip B, Aasen S. et al. Carbon dioxide insufflation for more comfortable endoscopic retrograde cholangiopancreatography: a randomized, controlled, double-blind trial. Endoscopy 2007; 39: 58-64
- 15 Lee SJ, Lee TH, Park SH. et al. Efficacy of carbon dioxide versus air insufflation according to different sedation protocols during therapeutic endoscopic retrograde cholangiopancreatography: Prospective, randomized, double-blind study. Digestive Endoscopy 2015; 27: 512-521
- 16 Xuan L, Yun-Jia Z, Jun D. et al. Carbon dioxide insufflation improves the intubation depth and total enteroscopy rate in single-balloon enteroscopy: a randomized, controlled, double-blind trial. Gut 2014; 63: 1560-1565
- 17 Lo SK, Fujii-Lau LL, Enestvedt BK. ASGE Technology Committee. et al. The use of carbon dioxide in gastrointestinal endoscopy. Gastrointest Endosc 2016; 83: 857-865