CC BY-NC-ND 4.0 · Eur J Dent 2016; 10(02): 286-291
DOI: 10.4103/1305-7456.178304
Review Article
Dental Investigation Society

A review of computer-aided design/computer-aided manufacture techniques for removable denture fabrication

Mehmet Selim Bilgin
1   Department of Prosthodontics, Sifa University, Izmir, Turkiye
,
Ebru Nur Baytaroğlu
1   Department of Prosthodontics, Sifa University, Izmir, Turkiye
,
Ali Erdem
1   Department of Prosthodontics, Sifa University, Izmir, Turkiye
,
Erhan Dilber
1   Department of Prosthodontics, Sifa University, Izmir, Turkiye
› Author Affiliations
Further Information

Publication History

Publication Date:
23 September 2019 (online)

ABSTRACT

The aim of this review was to investigate usage of computer-aided design/computer-aided manufacture (CAD/CAM) such as milling and rapid prototyping (RP) technologies for removable denture fabrication. An electronic search was conducted in the PubMed/MEDLINE, ScienceDirect, Google Scholar, and Web of Science databases. Databases were searched from 1987 to 2014. The search was performed using a variety of keywords including CAD/CAM, complete/partial dentures, RP, rapid manufacturing, digitally designed, milled, computerized, and machined. The identified developments (in chronological order), techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication are summarized. Using a variety of keywords and aiming to find the topic, 78 publications were initially searched. For the main topic, the abstract of these 78 articles were scanned, and 52 publications were selected for reading in detail. Full-text of these articles was gained and searched in detail. Totally, 40 articles that discussed the techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication and the articles were incorporated in this review. Totally, 16 of the papers summarized in the table. Following review of all relevant publications, it can be concluded that current innovations and technological developments of CAD/CAM and RP allow the digitally planning and manufacturing of removable dentures from start to finish. As a result according to the literature review CAD/CAM techniques and supportive maxillomandibular relationship transfer devices are growing fast. In the close future, fabricating removable dentures will become medical informatics instead of needing a technical staff and procedures. However the methods have several limitations for now.

 
  • REFERENCES

  • 1 Lima JM, Anami LC, Araujo RM, Pavanelli CA. Removable partial dentures: Use of rapid prototyping. J Prosthodont 2014; 23: 588-91
  • 2 Di Giacomo GA, Cury PR, de Araujo NS, Sendyk WR, Sendyk CL. Clinical application of stereolithographic surgical guides for implant placement: Preliminary results. J Periodontol 2005; 76: 503-7
  • 3 Sarment DP, Sukovic P, Clinthorne N. Accuracy of implant placement with a stereolithographic surgical guide. Int J Oral Maxillofac Implants 2003; 18: 571-7
  • 4 Sun J, Zhang FQ. The application of rapid prototyping in prosthodontics. J Prosthodont 2012; 21: 641-4
  • 5 Webb PA. A review of rapid prototyping (RP) techniques in the medical and biomedical sector. J Med Eng Technol 2000; 24: 149-53
  • 6 Miyazaki T, Hotta Y, Kunii J, Kuriyama S, Tamaki Y. A review of dental CAD/CAM: Current status and future perspectives from 20 years of experience. Dent Mater J 2009; 28: 44-56
  • 7 Kanazawa M, Inokoshi M, Minakuchi S, Ohbayashi N. Trial of a CAD/CAM system for fabricating complete dentures. Dent Mater J 2011; 30: 93-6
  • 8 Busch M, Kordass B. Concept and development of a computerized positioning of prosthetic teeth for complete dentures. Int J Comput Dent 2006; 9: 113-20
  • 9 Goodacre CJ, Garbacea A, Naylor WP, Daher T, Marchack CB, Lowry J. CAD/CAM fabricated complete dentures: Concepts and clinical methods of obtaining required morphological data. J Prosthet Dent 2012; 107: 34-46
  • 10 Inokoshi M, Kanazawa M, Minakuchi S. Evaluation of a complete denture trial method applying rapid prototyping. Dent Mater J 2012; 31: 40-6
  • 11 Kawahata N, Ono H, Nishi Y, Hamano T, Nagaoka E. Trial of duplication procedure for complete dentures by CAD/CAM. J Oral Rehabil 1997; 24: 540-8
  • 12 Maeda Y, Minoura M, Tsutsumi S, Okada M, Nokubi T. A CAD/CAM system for removable denture. Part I: Fabrication of complete dentures. Int J Prosthodont 1994; 7: 17-21
  • 13 Sun Y, Lü P, Wang Y. Study on CAD and RP for removable complete denture. Comput Methods Programs Biomed 2009; 93: 266-72
  • 14 Zhang YD, Jiang JG, Liang T, Hu WP. Kinematics modeling and experimentation of the multi-manipulator tooth-arrangement robot for full denture manufacturing. J Med Syst 2011; 35: 1421-9
  • 15 Abduo J, Lyons K, Bennamoun M. Trends in computer-aided manufacturing in prosthodontics: A review of the available streams. Int J Dent 2014; 2014: 783948
  • 16 Rekow ED, Erdman AG, Riley DR, Klamecki B. CAD/CAM for dental restorations – Some of the curious challenges. IEEE Trans Biomed Eng 1991; 38: 314-8
  • 17 Kattadiyil MT, Goodacre CJ, Baba NZ. CAD/CAM complete dentures: A review of two commercial fabrication systems. J Calif Dent Assoc 2013; 41: 407-16
  • 18 Sirirungrojying S, Srisintorn S, Akkayanont P. Psychometric profiles of temporomandibular disorder patients in southern Thailand. J Oral Rehabil 1998; 25: 541-4
  • 19 Sülün T, Akkayan B, Duc JM, Rammelsberg P, Tuncer N, Gernet W. Axial condyle morphology and horizontal condylar angle in patients with internal derangement compared to asymptomatic volunteers. Cranio 2001; 19: 237-45
  • 20 Williams RJ, Bibb R, Rafik T. A technique for fabricating patterns for removable partial denture frameworks using digitized casts and electronic surveying. J Prosthet Dent 2004; 91: 85-8
  • 21 Eggbeer D, Bibb R, Williams R. The computer-aided design and rapid prototyping fabrication of removable partial denture frameworks. Proc Inst Mech Eng H 2005; 219: 195-202
  • 22 Bibb RJ, Eggbeer D, Williams RJ, Woodward A. Trial fitting of a removable partial denture framework made using computer-aided design and rapid prototyping techniques. Proc Inst Mech Eng H 2006; 220: 793-7
  • 23 Guo-Dong Y, Wen-He L, Dai N. The Computer-Aided Design and Rapid Prototyping Fabrication of Removable Partial Denture Framework. Paper Presented at: Computer Science and Information Technology, 2009. ICCSIT 2009. 2nd IEEE International Conference on; 2009
  • 24 Jevremović D, Kojić V, Bogdanović G, Puškar T, Eggbeer D, Thomas D. et al. A selective laser melted Co-Cr alloy used for the rapid manufacture of removable partial denture frameworks: Initial screening of biocompatibility. J Serbian Chem Soc 2011; 76: 43-52
  • 25 Alifui-Segbaya F, Foley P, Williams R. The corrosive effects of artificial saliva on cast and rapid manufacture-produced cobalt chromium alloys. Rapid Prototyp J 2013; 19: 95-9
  • 26 Yoon TH, Madden JC, Chang WG. A technique to restore worn denture teeth on a partial removable dental prosthesis by using ceramic onlays with CAD/CAM technology. J Prosthet Dent 2013; 110: 331-2
  • 27 Yamamoto S, Kanazawa M, Iwaki M, Jokanovic A, Minakuchi S. Effects of offset values for artificial teeth positions in CAD/CAM complete denture. Comput Biol Med 2014; 52: 1-7
  • 28 Infante L, Yilmaz B, McGlumphy E, Finger I. Fabricating complete dentures with CAD/CAM technology. J Prosthet Dent 2014; 111: 351-5
  • 29 Bilgin MS, Erdem A, Aglarci OS, Dilber E. Fabricating complete dentures with CAD/CAM and RP technologies. J Prosthodont. 2015 Jun 1. doi: 10.1111/jopr.12302. [Epub ahead of print]
  • 30 Beuer F, Schweiger J, Edelhoff D. Digital dentistry: An overview of recent developments for CAD/CAM generated restorations. Br Dent J 2008; 204: 505-11
  • 31 Hazeveld A, Huddleston SlaterJJ, Ren Y. Accuracy and reproducibility of dental replica models reconstructed by different rapid prototyping techniques. Am J Orthod Dentofacial Orthop 2014; 145: 108-15
  • 32 Brkic B, France N, Clare AT, Sutcliffe CJ, Chalker PR, Taylor S. Development of quadrupole mass spectrometers using rapid prototyping technology. J Am Soc Mass Spectrom 2009; 20: 1359-65
  • 33 Karatas OH, Toy E. Three-dimensional imaging techniques: A literature review. Eur J Dent 2014; 8: 132-40
  • 34 Gumus HO, Dincel M, Buyuk SK, Kilinc HI, Bilgin MS, Zortuk M. The effect of pouring time on the dimensional stability of casts made from conventional and extended-pour irreversible hydrocolloids by 3D modelling. J Dent Sci 2015; 10: 275-81
  • 35 Nalcaci R, Topcuoglu T, Ozturk F. Comparison of Bolton analysis and tooth size measurements obtained using conventional and three-dimensional orthodontic models. Eur J Dent 2013; 7 (Suppl. 01) S66-70
  • 36 Han J, Wang Y, Lü P. A preliminary report of designing removable partial denture frameworks using a specifically developed software package. Int J Prosthodont 2010; 23: 370-5
  • 37 Williams RJ, Bibb R, Eggbeer D, Collis J. Use of CAD/CAM technology to fabricate a removable partial denture framework. J Prosthet Dent 2006; 96: 96-9
  • 38 Bidra AS, Taylor TD, Agar JR. Computer-aided technology for fabricating complete dentures: Systematic review of historical background, current status, and future perspectives. J Prosthet Dent 2013; 109: 361-6