CC BY-NC-ND 4.0 · Endosc Int Open 2018; 06(07): E789-E796
DOI: 10.1055/a-0614-2390
Original article
Owner and Copyright © Georg Thieme Verlag KG 2018

Use of over-the-scope-clip (OTSC) improves outcomes of high-risk adverse outcome (HR-AO) non-variceal upper gastrointestinal bleeding (NVUGIB)

Ravishankar Asokkumar
1   Singapore General Hospital, Singapore
,
Roy Soetikno
1   Singapore General Hospital, Singapore
2   Duke Graduate School of Medicine – National University of Singapore, Singapore
,
Andres Sanchez-Yague
3   Hospital Costa del Sol, Marbella, Malaga, Spain
,
Lim Kim Wei
1   Singapore General Hospital, Singapore
,
Ennaliza Salazar
1   Singapore General Hospital, Singapore
,
Jing Hieng Ngu
1   Singapore General Hospital, Singapore
2   Duke Graduate School of Medicine – National University of Singapore, Singapore
› Author Affiliations
Further Information

Publication History

submitted 06 February 2018

accepted after revision 13 April 2018

Publication Date:
04 July 2018 (online)

Abstract

Background and study aims Endoscopic treatment of non-variceal upper gastrointestinal bleeding (NVUGIB) with high-risk adverse outcome (HR-AO) features has a high risk of failure. We studied the safety and efficacy of over-the-scope clips (OTSC) to treat these lesions.

Patients and methods We included patients who were treated using OTSC for NVUGIB from January 2015 to October 2017. We studied rebleeding and mortality rates and used the Rockall data and our institution’s prior data for comparison. We used descriptive and chi-square statistics.

Results We studied 18 patients with 19 bleeding lesions: 9 (47 %) duodenal ulcers, 4 (21 %) Dieulafoy’s lesion, 3 (16 %) gastric ulcer, and 3 (16 %) bleeding after gastric biopsy, gastric polypectomy and endoscopic ultrasound-guided fine-needle aspiration of peri-gastric mass. We applied OTSC as the first-line treatment in 10 (53 %) and as the second-line treatment in 9 (47 %) bleeding lesions. Continued bleeding after OTSC occurred in six patients, but we treated it successfully and achieved complete hemostasis in all patients. We found OTSC use significantly decreased (0 % vs. 53 %, P < 0.01) and reduced (0 % vs. 24 %, P = 0.08) the rebleeding rate in our high-risk (RS ≥ 8) and intermediate-risk (RS = 4 – 7) Rockall score patients as compared to the rates reported by the Rockall study, respectively. When compared to our institution’s prior study, we found a decrease in the rebleeding rate with OTSC (0 % vs. 21 %, P = 0.06) in our intermediate-to-high risk Rockall score patients (RS ≥ 4). There was no difference in mortality rates as compared to both control studies.

Conclusion Use of OTSC is safe, efficacious and appears superior to standard treatment for HR-AO NVUGIB. OTSC should be considered as first-line treatment for HR-AO bleeding.

 
  • References

  • 1 Barkun AN, Bardou M, Kuipers EJ. et al. International consensus recommendations on the management of patients with nonvariceal upper gastrointestinal bleeding. Ann Intern Med 2010; 152: 101-113
  • 2 Gralnek IM, Dumonceau JM, Kuipers EJ. et al. Diagnosis and management of nonvariceal upper gastrointestinal hemorrhage: European Society of Gastrointestinal Endoscopy (ESGE) Guideline. Endoscopy 2015; 47: a1-46
  • 3 Laine L, Jensen DM. Management of patients with ulcer bleeding. Am J Gastroenterol 2012; 107: 345-360
  • 4 Barkun AN, Martel M, Toubouti Y. et al. Endoscopic hemostasis in peptic ulcer bleeding for patients with high-risk lesions: a series of meta-analyses. Gastrointest Endosc 2009; 69: 786-799
  • 5 Kato M, Jung Y, Gromski MA. et al. Prospective, randomized comparison of 3 different hemoclips for the treatment of acute upper GI hemorrhage in an established experimental setting. Gastrointest Endosc 2012; 75: 3-10
  • 6 Richter-Schrag HJ, Glatz T, Walker C. et al. First-line endoscopic treatment with over-the-scope clips significantly improves the primary failure and rebleeding rates in high-risk gastrointestinal bleeding: A single-center experience with 100 cases. World J Gastroenterol 2016; 22: 9162-9171
  • 7 Wedi E, Gonzalez S, Menke D. et al. One hundred and one over-the-scope-clip applications for severe gastrointestinal bleeding, leaks, and fistulas. World J Gastroenterol 2016; 22: 1844-1853
  • 8 Lau JY, Sung J, Hill C. et al. Systematic review of the epidemiology of complicated peptic ulcer disease: incidence, recurrence, risk factors and mortality. Digestion 2011; 84: 102-113
  • 9 Asokkumar R, Kaltenbach T, Soetikno R. et al. Use of over-the-scope clip to treat bleeding duodenal ulcers. Gastrointest Endosc 2016; 83: 459-460
  • 10 Asokkumar R, Soetikno R. Misplaced “bear claw” in a bleeding gastric ulcer: What next?. Gastrointest Endosc 2016; 84: 366-367
  • 11 Rockall TA, Logan RF, Devlin HB. et al. Risk assessment after acute upper gastrointestinal hemorrhage. Gut 1996; 38: 316-321
  • 12 Rauws EA, Kool G, Bolwerk C. New approaches to endoscopic therapy for a haemostasis upper GI bleed. Scand J Gastroenterol Suppl 1996; 218: 116-123
  • 13 Wang CY, Qin J, Wang J. et al. Rockall score in predicting outcomes of elderly patients with acute upper gastrointestinal bleeding. World J Gastroenterol 2013; 19: 3466-3472
  • 14 Kim BJ, Park MK, Kim SJ. et al. Comparison of scoring systems for the prediction of outcomes in patients with nonvariceal upper gastrointestinal bleeding: a prospective study. Dig Dis Sci 2009; 54: 2523-2529
  • 15 Stanley AJ, Laine L, Dalton HR. et al. Comparison of risk scoring systems for patients presenting with upper gastrointestinal bleeding: international multicentre prospective study. BMJ 2017; 356: i6432
  • 16 Schmidt A, Goelder S, Messmann H. et al. Over-the-scope-clips versus standard endoscopic therapy in patients with recurrent peptic ulcer bleeding and a prospective randomized, multicentre trial (Sting). Gastrointest Endosc 2017; 85: AB50
  • 17 Wedi E, Fischer A, Hochberger J. et al. Multicenter evaluation of first-line endoscopic treatment with the OTSC in acute non-variceal upper gastrointestinal bleeding and comparison with the Rockall cohort: the FLETRock study. Surg Endosc 2018; 32: 307-314
  • 18 Brandler J, Baruah A, Zeb M. et al. Efficacy of over-the-scope clips in management of high-risk gastrointestinal bleeding. Clin Gastroenterol Hepatol 2018; 16: 690-696.e1
  • 19 Chan SM, Chiu PW, Teoh AY. et al. Use of the Over-the-scope clip for treatment of refractory upper gastrointestinal bleeding: a case series. Endoscopy 2014; 46: 428-431
  • 20 Lamberts R, Koch A, Binner C. et al. Use of over-the-scope clips (OTSC) for hemostasis in gastrointestinal bleeding in patients under antithrombotic therapy. Endosc Int Open 2017; 5: E324-E330
  • 21 Wedi E, von Renteln D, Gonzalez S. et al. Use of the over-the-scope-clip (OTSC) in non-variceal upper gastrointestinal bleeding in patients with severe cardiovascular comorbidities: a retrospective study. Endosc Int Open 2017; 5: E875-E882