CC BY-NC-ND 4.0 · Endosc Int Open 2019; 07(03): E367-E371
DOI: 10.1055/a-0841-3350
Original article
Owner and Copyright © Georg Thieme Verlag KG 2019

Endoscopist’s occupational dose evaluation related to correct wearing of dosimeter during X-ray-guided procedures

Roberta Gerasia
1   IRCCS-ISMETT (Istituto Mediterraneo per i Trapianti e Terapie ad alta specializzazione), Palermo, Italy – Radiology Service, Department of Diagnostic and Therapeutic Services, Palermo, Italy
,
Dario Ligresti
2   IRCCS-ISMETT (Istituto Mediterraneo per i Trapianti e Terapie ad alta specializzazione), Palermo, Italy – Endoscopy Service, Department of Diagnostic and Therapeutic Services, Palermo, Italy
,
Fabio Cipolletta
2   IRCCS-ISMETT (Istituto Mediterraneo per i Trapianti e Terapie ad alta specializzazione), Palermo, Italy – Endoscopy Service, Department of Diagnostic and Therapeutic Services, Palermo, Italy
,
Antonino Granata
2   IRCCS-ISMETT (Istituto Mediterraneo per i Trapianti e Terapie ad alta specializzazione), Palermo, Italy – Endoscopy Service, Department of Diagnostic and Therapeutic Services, Palermo, Italy
,
Ilaria Tarantino
2   IRCCS-ISMETT (Istituto Mediterraneo per i Trapianti e Terapie ad alta specializzazione), Palermo, Italy – Endoscopy Service, Department of Diagnostic and Therapeutic Services, Palermo, Italy
,
Luca Barresi
2   IRCCS-ISMETT (Istituto Mediterraneo per i Trapianti e Terapie ad alta specializzazione), Palermo, Italy – Endoscopy Service, Department of Diagnostic and Therapeutic Services, Palermo, Italy
,
Michele Amata
2   IRCCS-ISMETT (Istituto Mediterraneo per i Trapianti e Terapie ad alta specializzazione), Palermo, Italy – Endoscopy Service, Department of Diagnostic and Therapeutic Services, Palermo, Italy
,
Sabrina Benenati
1   IRCCS-ISMETT (Istituto Mediterraneo per i Trapianti e Terapie ad alta specializzazione), Palermo, Italy – Radiology Service, Department of Diagnostic and Therapeutic Services, Palermo, Italy
,
Giuseppe Gallo
1   IRCCS-ISMETT (Istituto Mediterraneo per i Trapianti e Terapie ad alta specializzazione), Palermo, Italy – Radiology Service, Department of Diagnostic and Therapeutic Services, Palermo, Italy
,
Corrado Tafaro
1   IRCCS-ISMETT (Istituto Mediterraneo per i Trapianti e Terapie ad alta specializzazione), Palermo, Italy – Radiology Service, Department of Diagnostic and Therapeutic Services, Palermo, Italy
,
Roberto Miraglia
1   IRCCS-ISMETT (Istituto Mediterraneo per i Trapianti e Terapie ad alta specializzazione), Palermo, Italy – Radiology Service, Department of Diagnostic and Therapeutic Services, Palermo, Italy
,
Mario Traina
2   IRCCS-ISMETT (Istituto Mediterraneo per i Trapianti e Terapie ad alta specializzazione), Palermo, Italy – Endoscopy Service, Department of Diagnostic and Therapeutic Services, Palermo, Italy
› Author Affiliations
Further Information

Publication History

submitted 04 July 2018

accepted after revision 29 October 2018

Publication Date:
28 February 2019 (online)

Abstract

Background Since endoscopists performing procedures in the endoscopy suite can change their position by turning their back, side or front toward the X-ray source, this study aimed to establish whether dosimeter position affects the correct evaluation of an endoscopist’s personal radiation exposure during X-ray-guided procedures.

Materials and methods Between January and February 2018, two dosimeters specularly placed outside the lead apron (anterior one on the chest and posterior one on the back) measured endoscopists’ personal dose equivalent (Hp) during 62 X-ray-guided procedures on adult and pediatric patients. Procedures were divided into three groups considering the position taken by the endoscopist with respect to the radiation source. For each group, the difference between mean Hp from the anterior and posterior dosimeters was calculated.

Results A statistically significant difference in mean Hp was recorded for the endoscopists’ frontal and back positions (P = 0.014, and P < 0.00001, respectively). No significant difference was found in mean Hp for the side position (P = 0.489).

Conclusions The position of personal dosimeters affects the correct evaluation of endoscopists’ radiation exposure during X-ray-guided procedures when frontal and back positions were recorded. To correctly evaluate radiation doses, the whole-body dosimeter should be worn according to the position of the endoscopist with respect to the radiation source; otherwise, it results in an incorrect personal dose evaluation, which may lead to substantial underestimation of staff exposure.