Abstract
Background and study aim Use of endoscopic ultrasound-guided biliary drainage (EUS-BD) has recently increased. In EUS-BD, after puncturing the bile duct, dilation is performed and the stent is deployed. Due to adverse events (AEs) such as unexpected displacement of the guidewire, simplified procedures are required. Currently, stents with small-diameter delivery systems are being rapidly developed, expanding the possibilities for of EUS-BD without dilation. In this retrospective study, we aimed to evaluate the success rates and AEs in patients who underwent EUS-guided hepaticogastrostomy (EUS-HGS) or EUS-guided hepaticojejunostomy (EUS-HJS) without dilation.
Patients and methods Six consecutive patients with malignant biliary obstruction and failed transpapillary BD underwent EUS-HGS or EUS-HJS without dilation, deploying a 6-mm fully-covered self-expandable metallic stent with a 6-Fr delivery system.
Results The technical and clinical success rates were 100 %. There was one case each of stent migration and stent occlusion, and no other AEs were noted.
Conclusions EUS-HGS or EUS-HJS without dilation using a stent with a 6-Fr delivery system had high technical and clinical success rates; however, additional cases are required to validate the study findings.
Publication History
Received: 25 January 2020
Accepted: 09 April 2020
Article published online:
21 July 2020
© 2020. Owner and Copyright ©
© Georg Thieme Verlag KG
Stuttgart · New York
-
References
- 1 Dumonceau JM, Tringali A, Papanikolaou IS. et al. Endoscopic biliary stenting: indications, choice of stents, and results: European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline – Updated October 2017. Endoscopy 2018; 50: 910-930
- 2 Leung Ki EL, Napoleon B. Endoscopic ultrasound-guided biliary drainage: a change in paradigm?. World J Gastrointest Endosc 2019; 11: 345-353
- 3 Park DH, Lee TH, Paik WH. et al. Feasibility and safety of a novel dedicated device for one-step EUS-guided biliary drainage: a randomized trial. J Gastroenterol Hepatol 2015; 30: 1461-1466
- 4 Lee TH, Choi JH, Lee SS. et al. A pilot proof-of-concept study of a modified device for one-step endoscopic ultrasound-guided biliary drainage in a new experimental biliary dilatation animal model. World J Gastroenterol 2014; 20: 5859-5866
- 5 Amano M, Ogura T, Onda S. et al. Prospective clinical study of endoscopic ultrasound-guided biliary drainage using novel balloon catheter (with video). J Gastroenterol Hepatol 2017; 32: 716-720
- 6 Ogura T, Nakai Y, Itoi T. Novel fine gauge electrocautery dilator for endoscopic ultrasound-guided hepaticogastrostomy (with video). J Hepatobiliary Pancreat Sci 2019; 26: E3-E4
- 7 Honjo M, Itoi T, Tsuchiya T. et al. Safety and efficacy of ultra-tapered mechanical dilator for EUS-guided hepaticogastrostomy and pancreatic duct drainage compared with electrocautery dilator (with video). Endosc Ultrasound 2018; 7: 376-382
- 8 Paik WH, Lee TH, Park DH. et al. EUS-guided biliary drainage versus ERCP for the primary palliation of malignant biliary obstruction: a multicenter randomized clinical trial. Am J Gastroenterol 2018; 113: 987-997
- 9 Isayama H, Hamada T, Yasuda I. et al. TOKYO criteria 2014 for transpapillary biliary stenting. Dig Endosc 2015; 27: 259-264