CC BY-NC-ND 4.0 · Endosc Int Open 2021; 09(06): E836-E842
DOI: 10.1055/a-1386-3879
Original article

Use of ambient lighting during colonoscopy and its effect on adenoma detection rate and eye fatigue: results of a pilot study

Ryan T. Hoff
1   Advocate Lutheran General Hospital – Medicine, Park Ridge, Illinois, United States
,
Andrew Mazulis
1   Advocate Lutheran General Hospital – Medicine, Park Ridge, Illinois, United States
,
Meghana Doniparthi
1   Advocate Lutheran General Hospital – Medicine, Park Ridge, Illinois, United States
,
Assad Munis
1   Advocate Lutheran General Hospital – Medicine, Park Ridge, Illinois, United States
,
Anne Rivelli
2   Advocate Lutheran General Hospital – Russell Research Institute, Park Ridge, Illinois, United States
,
Asif Lakha
1   Advocate Lutheran General Hospital – Medicine, Park Ridge, Illinois, United States
,
Eli Ehrenpreis
1   Advocate Lutheran General Hospital – Medicine, Park Ridge, Illinois, United States
3   Rosalind Franklin University of Medicine and Science Chicago Medical School – Medicine, North Chicago, Illinois, United States
› Author Affiliations
TRIAL REGISTRATION: Non-Randomized, Single Center Clinical Trial NCT04441242 at clinicaltrials.gov

Abstract

Background and study aims Adenoma detection rate (ADR) appears to decrease as the number of consecutive hours performing procedures increases, and eye strain may be a contributing factor. Ambient light may improve symptoms of eye strain, but its effects have yet to be explored in the field of gastroenterology. We aim to determine if using ambient lighting during screening colonoscopy will maintain ADRs and improve eye strain symptoms compared with low lighting.

Methods At a single center, retrospective data were collected on colonoscopies performed under low lighting and compared to prospective data collected on colonoscopies with ambient lighting. Eye fatigue surveys were completed by gastroenterologists. Satisfaction surveys were completed by physicians and staff.

Results Of 498 low light and 611 ambient light cases, 172 and 220 adenomas were detected, respectively (P = 0.611). Under low lighting, the ADR decreased 5.6 % from first to last case of the day (P = 0.2658). With ambient lighting, the ADR increased by 2.80 % (P = 0.5445). The difference in the overall change in ADR between first and last cases with ambient light versus low light was statistically significant (8.40 % total unit change, P = 0.01). The average eye strain scores were 8.12 with low light, and 5.63 with ambient light (P = 0.3341).

Conclusions Performing screening colonoscopies with ambient light may improve the differential change in ADR that occurs from the beginning to the end of the day. This improvement in ADR may be related to improvement in operator fatigue. The effect of ambient light on eye strain is unclear. Further investigation is warranted on the impact of ambient light on symptoms of eye strain and ADR.



Publication History

Received: 29 September 2020

Accepted: 20 January 2021

Article published online:
27 May 2021

© 2021. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/)

Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany