Background Tension band wiring is the standard procedure for patellar fractures, but is associated with a high rate of implant related complications and implant failure. Tension band wiring may fail, especially with multifragmentary and comminuted fractures. Plate fixation of complex patellar fractures seems to be superior to wiring, both clinically and biomechanically. The aim of this study was to evaluate complications after locking plate fixation in patellar fractures two years after surgery and to access the functional outcome.
Material and Methods As part of a prospective case series, all patients who had received locking plate fixation of a patellar fracture between April 2013 and May 2018 were clinically examined two years postoperatively and potential complications were evaluated.
Results A total of 38 patients aged 19 – 87 years were included. Complications occurred in a total of five patients (13%), including one reactive prepatellar bursitis, one chronic infection and loss of reduction due to a dislocated pole fragment in three cases. The average active range of motion of the affected knee joint two years postoperatively was 133°. The Tegner activity scale score reached 3 points, the Lysholm score 95 points and the Kujala score 95 points.
Conclusion With an overall relatively low complication rate and good clinical outcome, dislocated distal pole fragments are a common complication after plate fixation of patellar fractures. If preoperative diagnostic testing shows a pole fragment, a modified hook-plate can be used, with the possibility of fixing the pole fragment.
Key words
multifragmentary patellar fracture - anterior locking plate fixation - tension band wiring - complication rate - displaced distale pole fragmentPublication History
Article published online:
19 April 2021
© 2021. Thieme. All rights reserved.
Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany
-
References/Literatur
- 1 Boström Å. Fracture of the patella. A study of 422 patellar fractures. Acta Orthop Scand 1972; 143: 1-80 doi:10.3109/ort.1972.43.suppl-143.01
- 2 Larsen P, Court-Brown CM, Vedel JO. et al. Incidence and Epidemiology of Patellar Fractures. Orthopedics 2016; 39: e1154-e1158 doi:10.3928/01477447-20160811-01
- 3 Wild M, Windolf J, Flohé S. Patellafrakturen. Unfallchirurg 2010; 113: 401-412 doi:10.1007/s00113-010-1768-x
- 4 Ortiguera CJ, Berry DJ. Patellar fracture after total knee arthroplasty. J Bone Joint Surg Am 2002; 84: 532-540 doi:10.2106/00004623-200204000-00004
- 5 Bengnér U, Johnell O, Redlund-Johnell I. Increasing incidence of tibia condyle and patella fractures. Acta Orthop Scand 1986; 57: 334-336
- 6 Torchia ME, Lewallen DG. Open fractures of the patella. J Orthop Trauma 1996; 10: 403-409 doi:10.1097/00005131-199608000-00007
- 7 Wurm S, Bühren V. Patellafrakturen. Trauma Berufskrankh 2015; 17: 153-159 doi:10.1007/s10039-015-0081-x
- 8 Larsen P, Rathleff MS, Østgaard SE. et al. Patellar fractures are associated with an increased risk of total knee arthroplasty: A Matched Cohort Study of 6096 Patellar Fractures with a mean follow-up of 14.3 Years. Bone Joint J 2018; 100-B: 1477-1481 doi:10.1302/0301-620X.100B11.BJJ-2018-0312.R2
- 9 Müller M, Allgöwer M, Schneider R, Willenegger H. Manual of internal Fixation: Techniques recommended by the AO-ASIF. Heidelberg: Springer; 1991
- 10 Labitzke R. Zuggurtungen – Richtiges und Falsches am Beispiel der Patellafraktur. Chirurg 1997; 68: 638-642
- 11 Issendorf W, Ahlers J, Ritter G. Die Drahtzuggurtungsosteosynthese – Untersuchungen zu Spannung und Fixierung des Osteosynthesedrahtes. Unfallchirurgie 1991; 16: 277
- 12 Lazaro LE, Wellman DS, Sauro G. et al. Outcomes after operative fixation of complete articular patellar fractures: assessment of functional impairment. J Bone Joint Surg Am 2013; 95: e96 1–8 doi:10.2106/jbjs.l.00012
- 13 Tian Y, Zhou F, Ji H. et al. Cannulated screw and cable are superior to modified tension band in the treatment of transverse patella fractures. Clin Orthop Relat Res 2011; 469: 3429-3435
- 14 Wang CX, Tan L, Qi BC. et al. A retrospective comparison of the modified tension band technique and the parallel titanium cannulated lag screw technique in transverse patella fracture. Chin J Traumatol 2014; 17: 208-213
- 15 Smith ST, Cramer KE, Karges DE. et al. Early complications in the operative treatment of patella fractures. J Orthop Trauma 1997; 11: 183-187
- 16 Chiang CC, Chen WM, Jeff Lin CF. et al. Comparison of a minimally invasive technique with open tension band wiring for displaced transverse patellar fractures. J Chin Med Assoc 2011; 74: 316-321
- 17 Levack B, Flannagan JP, Hobbs S. Results of surgical treatment of patellar fractures. J Bone Joint Surg Br 1985; 67: 416-419
- 18 Hung LK, Chan KM, Chow YN. et al. Fractured patella: operative treatment using the tension band principle. Injury 1985; 16: 343-347
- 19 Mehdi M, Husson JL, Polard JL. et al. Treatment results of fractures of the patella using pre-patellar tension wiring. Analysis of a series of 203 cases. Acta Orthop Belg 1999; 65: 188-196
- 20 Dargel J. et al. Biomechanical comparison of tension band and interfragmentary screw fixation with a new implant in transverse patella fractures. Injury 2010; 41: 156-160
- 21 Zhang Y, Xu Z, Zhong W. et al. Efficacy of K-wire tension band fixation compared with other alternatives for patella fractures: a meta-analysis. J Orthop Surg Res 2018; 13: 226
- 22 Wright PB, Kosmopoulos V, Coté RE. et al. FiberWire® is superior in strength to stainless steel wire for tension band fixation of transverse patellar fractures. Injury 2009; 40: 1200-1203 doi:10.1016/j.injury.2009.04.011
- 23 Hughes SC. et al. A new and effective tension-band braided polyester suture technique for transverse patellar fracture fixation. Injury 2007; 38: 212-222
- 24 Wurm S, Augat P, Bühren V. Biomechanical Assessment of Locked Plating for the Fixation of Patella Fractures. J Orthop Trauma 2015; 29: e305-e308 doi:10.1097/BOT.0000000000000309
- 25 Wagner FC, Neumann MV, Wolf S. et al. Biomechanical comparison of a 3.5 mm anterior locking plate to cannulated screws with anterior tension band wiring in comminuted patellar fractures. Injury 2020; 51: 1281-1287 doi:10.1016/j.injury.2020.03.030
- 26 Ellwein A, Lill H, Jensen G. et al. Die Plattenosteosynthese der Patellafraktur – Technik und erste Ergebnisse einer prospektiven Studie. Unfallchirurg 2017; 120: 753-760 doi:10.1007/s00113-016-0213-1
- 27 Ellwein A, Lill H, DeyHazra RO. et al. Outcomes after locked plating of displaced patella fractures: a prospective case series. Int Orthop 2019; 43: 2807-2815 doi:10.10007/s00264-019-04337-7
- 28 Wurm S, Bühren V, Augat P. Treating patella fractures with a locking patella plate – first clinical results. Injury 2018; 49 (Suppl. 01) S51-S55 doi:10.1016/S0020-1383(18)30304-8
- 29 Moore TB, Sampathi BR, Zamorano DP. et al. Fixed angle plate fixation of comminuted patellar fractures. Injury 2018; 49: 1203-1207 doi:10.1016/j.injury.2018.03.030
- 30 AO-Foundation. Fracture and dislocation classification compendium. J Orthop Trauma 2018; 32 (Suppl. 01)
- 31 Speck M, Regazzoni P. Classification of patellar fractures. Z Unfallchir Versicherungsmed 1994; 87: 27-30
- 32 Wild M, Khayal T, Miersch D. et al. Dynamic cerclage wiring of patellar fractures. Complications and midterm functional results. Unfallchirurg 2008; 111: 892-897
- 33 Mao N, Liu D, Ni H. et al. Comparison of the cable pin system with conventional open surgery for transverse patella fractures. Clin Orthop Relat Res 2013; 471: 2361-2366
- 34 Siljander M, Koueiter DM, Gandhi S. et al. Outcomes Following Low-Profile Mesh Plate Osteosynthesis of Patella Fractures. J Knee Surg 2018; 31: 919-926 doi:10.1055/s-0038-1625958
- 35 Volgas D, Dreger TK. The Use of Mesh Plates for Difficult Fractures of the Patella. J Knee Surg 2017; 30: 200-203 doi:10.1055/s-0037-1598078
- 36 Wild M, Fischer K, Hilsenbeck F. et al. Treating patella fractures with a fixed-angle patella plate- A prospective observational study. Injury 2016; 47: 1737-1743 doi:10.1016/j.injury.2016.06.018
- 37 Lazaro LE, Wellmann DS, Pardee NC. et al. Effect of computerized tomography on classification and treatment plan for patellar fractures. J Orthop Trauma 2013; 27: 336-344 doi:10.1097/BOT.0b013e318270dfe7
- 38 Thelen S, Betsch M, Schneppendahl J. et al. Fixation of multifragmentary patella fractures using a bilateral fixed-angle plate. Orthopedics 2013; 36: e1437-e1443
- 39 Thelen S, Schneppendahl J, Baumgärtner R. et al. Cyclic long-term loading of a bilateral fixed-angle plate in comparison with tension band wiring with K-wires or cannulated screws in transverse patella fractures. Knee Surg Sports Traumatol Arthrosc 2013; 21: 311-317
- 40 Thelen S, Schneppendahl J, Jopen E. et al. Biomechanical cadaver testing of a fixed-angle plate in comparison to tension wiring and screw fixation in transverse patella fractures. Injury 2012; 43: 1290-1295
- 41 Liu F, Wang S, Zhu Y. et al. Patella rings for treatment of patellar fracture. Eur J Orthop Surg Traumatol 2014; 24: 105-109
- 42 Yao C, Sun J, Wu J. et al. Clinical outcomes of Ti-Ni shape-memory patella concentrator combined with cannulated compression screws in the treatment of C2 and C3 patella fracture: a retrospective study of 54 cases. BMC Musculoskelet Disord 2020; 21: 506 doi:10.1186/s12891-020-03536-3
- 43 Pesch S, Kirchhoff K, Biberthaler P. et al. Patellafrakturen. Unfallchirurg 2019; 122: 225-237 doi:10.1007/s00113-019-0611-2
- 44 Lazaro LE, Wellman DS, Klinger CE. et al. Quantitative and qualitative assessment of bone perfusion and arterial contributions in a patellar fracture model using gadolinium-enhanced magnetic resonance imaging: a cadaveric study. J Bone Joint Surg Am 2013; 95: e1401-e1407 doi:10.2106/JBJS.L.00401
- 45 McLaughlin HL. Repair of major tendon ruptures by buried removable suture. Am J Surg 1947; 74: 758-764 doi:10.1016/0002-9610(47)90233-x
- 46 Deutsche Gesellschaft für Orthopädie und Unfallchirurgie. Hrsg. Nachbehandlungsempfehlungen. 5. Aufl.. 2019. Im Internet (Stand: 03.02.2021): https://dgou.de/fileadmin/user_upload/Dokumente/Qualitaet_und_Sicherheit/2019_Nachbehandlungsempfehlungen.pdf