RSS-Feed abonnieren
DOI: 10.1055/a-1526-1208
Common bile duct size in malignant distal obstruction and lumen-apposing metal stents: a multicenter prospective study
Abstract
Background and study aims Feasibility of EUS-guided choledochoduodenostomy (EUS-CDS) using available lumen-apposing stents (LAMS) is limited by the size of the common bile duct (CBD) (≤ 12 mm, cut-off for experts; 15 mm, cut-off for non-experts). We aimed to assess the prevalence and predictive factors associated with CBD size ≥ 12 and 15 mm in naïve patients with malignant distal biliary obstruction (MDBO).
Patients and methods This was a prospective cohort study involving 22 centers with assessment of CBD diameter and subjective feasibility of the EUS-CDS performance in naïve jaundiced patients undergoing EUS evaluation for MDBO.
Results A total of 491 patients (mean age 69 ± 12 years) with mean serum bilirubin of 12.7 ± 6.6 mg/dL entered the final analysis. Dilation of the CBD ≥ 12 and 15 mm was detected in 78.8 % and 51.9 % of cases, respectively. Subjective feasibility of EUS-CDS was expressed by endosonographers in 91.2 % for a CBD ≥ 12 mm and in 96.5 % for a CBD ≥ 15 mm. On multivariate analysis, age (P < 0.01) and bilirubin level (P ≤ 0.001) were the only factors associated with both CBD dilation ≥ 12 and ≥ 15 mm. These variables were poorly associated with the extent of duct dilation; however, based on them a prediction model could be constructed that satisfactorily predicted CBD size ≥ 12 mm in patients at least 70 years and a bilirubin level ≥ 7 mg/dL.
Conclusions Our study showed that at presentation in a large cohort of patients with MDBO, EUS-CDS can be potentially performed in three quarters to half of cases by expert and less experienced endosonographers, respectively. Dedicated stents or devices with different designs able to overcome the limitations of existing electrocautery-enhanced LAMS for EUS-CDS are needed.
Publikationsverlauf
Eingereicht: 04. April 2021
Angenommen: 26. Mai 2021
Artikel online veröffentlicht:
12. November 2021
© 2021. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/)
Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany
-
References
- 1 Kahaleh M, Artifon ELA, Perez-Miranda M. et al. EUS-guided drainage: Summary of therapeutic EUS consortium meeting. Endosc Ultrasound 2019; 8: 151-160
- 2 Boulay BR, Lo SK. Endoscopic ultrasound-guided biliary drainage. Gastrointest Endosc Clin N Am 2018; 28: 171-185
- 3 Sharaiha RZ, Khan MA, Kamal F. et al. Efficacy and safety of EUS-guided biliary drainage in comparison with percutaneous biliary drainage when ERCP fails: a systematic review and meta-analysis. Gastrointest Endosc 2017; 85: 904-914
- 4 Park JK, Woo YS, Noh DH. et al. Efficacy of EUS-guided and ERCP-guided biliary drainage for malignant biliary obstruction: prospective randomized controlled study. Gastrointest Endosc 2018; 88: 277-282
- 5 Bang JY, Navaneethan U, Hasan M. et al. Stent placement by EUS or ERCP for primary biliary decompression in pancreatic cancer: a randomized trial (with videos). Gastrointest Endosc 2018; 88: 9-17
- 6 Paik WH, Lee TH, Park DH. et al. EUS-guided biliary drainage versus ERCP for the primary palliation of malignant biliary obstruction: a multicenter randomized clinical trial. Am J Gastroenterol 2018; 113: 987-997
- 7 Frazzoni L, Fuccio L, Larghi A. EUS-guided biliary drainage versus ERCP for the primary treatment of malignant distal biliary obstruction: time for a large randomized study. Gastrointest Endosc 2018; 88: 571-572
- 8 Attili F, Rimbaş M, Galasso D. et al. Fluoroless endoscopic ultrasound-guided biliary drainage after failed ERCP with a novel lumen-apposing metal stent mounted on a cautery-tipped delivery system. Endoscopy 2015; 47 Suppl 1: E619-E620
- 9 Kunda R, Pérez-Miranda M, Will U. et al. EUS-guided choledochoduodenostomy for malignant distal biliary obstruction using a lumen-apposing fully covered metal stent after failed ERCP. Surg Endosc 2016; 30: 5002-5008
- 10 Brückner S, Arlt A, Hampe J. Endoscopic ultrasound-guided biliary drainage using a lumen-apposing self-expanding metal stent: a case series. Endoscopy 2015; 47: 858-861
- 11 Anderloni A, Buda A, Carrara S. et al. Single-session double-stent placement in concomitant malignant biliary and duodenal obstruction with a cautery-tipped lumen apposing metal stent. Endoscopy 2016; 48: E321-E322
- 12 French JB, Coe AW, Pawa R. Endoscopic ultrasound-guided choledochoduodenostomy with a lumen-apposing, self-expandable fully covered metal stent for palliative biliary drainage. Clin J Gastroenterol 2016; 9: 79-85
- 13 Anderloni A, Leo MD, Carrara S. et al. Endoscopic ultrasound-guided transmural drainage by cautery-tipped lumen-apposing metal stent: exploring the possible indications. Ann Gastroenterol 2018; 31: 735-741
- 14 Tsuchiya T, Teoh AYB, Itoi T. et al. Long-term outcomes of EUS-guided choledochoduodenostomy using a lumen-apposing metal stent for malignant distal biliary obstruction: A prospective multicenter study. Gastrointest Endosc 2018; 87: 1138-1146
- 15 Puga M, Pallarès N, Velásquez-Rodríguez J. et al. Endoscopic biliary drainage in unresectable biliary obstruction: the role of endoscopic ultrasound-guidance in a cohort study. Rev Esp Enferm Dig 2019; 111: 683-689
- 16 Jacques J, Privat J, Pinard F. et al. Endoscopic ultrasound-guided choledochoduodenostomy with electrocautery-enhanced lumen-apposing stents: A retrospective analysis. Endoscopy 2019; 51: 540-547
- 17 Anderloni A, Fugazza A, Troncone E. et al. Single-stage EUS-guided choledochoduodenostomy using a lumenapposing metal stent for malignant distal biliary obstruction. Gastrointest Endosc 2019; 89: 69-76
- 18 El Chafic AH, Shah JN, Hamerski C. et al. EUS-Guided Choledochoduodenostomy for Distal Malignant Biliary Obstruction Using Electrocautery-Enhanced Lumen-Apposing Metal Stents: First US, Multicenter Experience. Dig Dis Sci 2019; 64: 3321-3327
- 19 Fabbri C, Fugazza A, Binda C. et al. Beyond palliation: using EUS-guided choledochoduodenostomy with a lumen-apposing metal stent as a bridge to surgery. a case series. J Gastrointestin Liver Dis 2019; 28: 125-128
- 20 Jacques J, Privat J, Pinard F. et al. EUS-guided choledochoduodenostomy using electrocautery-enhanced lumen-apposing metal stents: a French multicenter study after implementation of the technique (with video). Gastrointest Endosc 2020; 92: 134-141
- 21 Giovannini M, Moutardier V, Pesenti C. et al. Endoscopic ultrasound-guided bilioduodenal anastomosis: a new technique for biliary drainage. Endoscopy 2001; 33: 898-900
- 22 Rimbaş M, Larghi A, Kunda R. EUS-guided biliary drainage: Is it ready for prime time?. Endosc Ultrasound 2017; 6: S122-S126
- 23 Hedjoudje A, Sportes A, Grabar S. et al. Outcomes of endoscopic ultrasound-guided biliary drainage: A systematic review and meta-analysis. United European Gastroenterol J 2019; 7: 60-68
- 24 Poincloux L, Rouquette O, Buc E. et al. Endoscopic ultrasound-guided biliary drainage after failed ERCP: cumulative experience of 101 procedures at a single center. Endoscopy 2015; 47: 794-801
- 25 Artifon ELA, Visconti TAC, Brunaldi VO. Choledochoduodenostomy: Outcomes and limitations. Endosc Ultrasound 2019; 8: S72-S78