Endoscopic electroincision of challenging benign biliopancreatic strictures

Andrea Tringali
1   Digestive Endoscopy Unit, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
2   Centre for Endoscopic Research Therapeutics and Training (CERTT), Università Cattolica del Sacro Cuore, Rome, Italy
,
Sebastian Manuel Milluzzo
3   Digestive Endoscopy Unit and Gastroenterology, Fondazione Poliambulanza Istituto Ospedaliero, Brescia, Italy
,
Vincenzo Perri
1   Digestive Endoscopy Unit, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
2   Centre for Endoscopic Research Therapeutics and Training (CERTT), Università Cattolica del Sacro Cuore, Rome, Italy
,
Tommaso Schepis
2   Centre for Endoscopic Research Therapeutics and Training (CERTT), Università Cattolica del Sacro Cuore, Rome, Italy
,
Vincenzo Bove
1   Digestive Endoscopy Unit, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
,
Guido Costamagna
1   Digestive Endoscopy Unit, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
2   Centre for Endoscopic Research Therapeutics and Training (CERTT), Università Cattolica del Sacro Cuore, Rome, Italy
› Author Affiliations

Abstract

Background and study aims Endoscopic drainage of benign biliary and pancreatic strictures can be challenging, especially when tightness of the stenosis does not allow passage of mechanical and pneumatic dilation catheters. Electroincision of benign biliopancreatic can be considered in selected cases.

Patients and methods Three male patients (mean age 33 years, range 9–60) underwent endoscopic retrograde cholangiopancreatography to drain anastomotic biliary stricture (ABS) following orthotopic liver transplantation (n = 2) and pancreatic duct stenosis due to abdominal trauma (n = 1). The biliopancreatic strictures could be passed only with a thin 0.020-inch hydrophilic guidewire. Conventional mechanical and pneumatic dilators failed to pass the strictures due to weakness of the guidewire. Therefore, electrosurgical incision by over-the-wire 6Fr cystotome or needle-knife was attempted using pure cut current.

Results The two cases of ABS were approached also by cholangioscopy and the 6Fr cystotome easily passed the strictures, allowing subsequent pneumatic dilatation and insertion of multiple plastic stents. The patient with a pancreatic duct stricture underwent electrosurgical incision using a thin needle knife over-the-wire, resulting in insertion of a 7Fr pancreatic stent. No adverse events occurred; all the patients were discharged within 24 to 48 hours.

Conclusions Electrosurgical incision of benign biliopancreatic strictures could be considered in selected patients whom conventional dilation techniques fail.



Publication History

Received: 25 April 2022

Accepted after revision: 30 May 2022

Article published online:
14 September 2022

© 2022. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/)

Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany

 
  • References

  • 1 Savides TJ, Varadarajulu S, Palazzo L. et al. EUS 2008 Working Group document: evaluation of EUS-guided hepaticogastrostomy. Gastrointest Endosc 2009; 69: S3-S7
  • 2 Bokemeyer A, Müller F, Niesert H. et al. Percutaneous-transhepatic-endoscopic rendezvous procedures are effective and safe in patients with refractory bile duct obstruction. United Eur Gastroenterol J 2019; 7: 397-404
  • 3 Dumonceau J-M, Tringali A, Papanikolaou I. et al. Endoscopic biliary stenting: indications, choice of stents, and results: European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline – Updated October 2017. Endoscopy 2018; 50: 910-930
  • 4 Wong MYW, Saxena P, Kaffes AJ. Benign biliary strictures: a systematic review on endoscopic treatment options. Diagnostics 2020; 10: 221
  • 5 Oracz G, Pertkiewicz J, Kierkus J. et al. Efficiency of pancreatic duct stenting therapy in children with chronic pancreatitis. Gastrointest Endosc 2014; 80: 1022-1029
  • 6 Lee YY, Gwak G-Y, Lee KH. et al. Predictors of the feasibility of primary endoscopic management of biliary strictures after adult living donor liver transplantation. Liver Transplant Soc 2011; 17: 1467-1473
  • 7 Parsi MA. Direct peroral cholangioscopy. World J Gastrointest Endosc 2014; 6: 1-5
  • 8 Woo YS, Lee JK, Noh DH. et al. SpyGlass cholangioscopy-assisted guidewire placement for post-LDLT biliary strictures: a case series. Surg Endosc 2016; 30: 3897-3903
  • 9 Kumar S. Cholangioscopy-directed endoscopic intervention for post-liver transplantation anastomotic biliary stricture. Gastrointest Endosc 2015; 81: 1014-1015
  • 10 Wright H, Sharma S, Gurakar A. et al. Management of biliary stricture guided by the Spyglass Direct Visualization System in a liver transplant recipient: an innovative approach. Gastrointest Endosc 2008; 67: 1201-1203
  • 11 Tsutsumi K, Kato H, Sakakihara I. et al. Dilation of a severe bilioenteric or pancreatoenteric anastomotic stricture using a Soehendra Stent Retriever. World J Gastrointest Endosc 2013; 5: 412-416
  • 12 Samanta J, Dhaka N, Sinha SK. et al. Endoscopic incisional therapy for benign esophageal strictures: Technique and results. World J Gastrointest Endosc 2015; 7: 1318-1326
  • 13 Deng S, Cao Y, Gu J. et al. Endoscopic diagnosis and treatment of complete anastomosis stenosis after colorectal resection without protective ileostomy: report of two cases and literature review. J Int Med Res 2020; 48 DOI: 10.1177/0300060520914833.
  • 14 Raskin JB, Manten H, Harary A. et al. Transendoscopic electrosurgical incision of lower esophageal (Schatzki) rings: a new treatment modality. Gastrointest Endosc 1985; 31: 391-393
  • 15 Simmons DT, Baron TH. Electroincision of refractory esophagogastric anastomotic strictures. Dis Esophagus Off J Int Soc Dis Esophagus 2006; 19: 410-414
  • 16 Lee TH, Lee S-H, Park J-Y. et al. Primary incisional therapy with a modified method for patients with benign anastomotic esophageal stricture. Gastrointest Endosc 2009; 69: 1029-1033
  • 17 Muto M, Ezoe Y, Yano T. et al. Usefulness of endoscopic radial incision and cutting method for refractory esophagogastric anastomotic stricture (with video). Gastrointest Endosc 2012; 75: 965-972
  • 18 Yano T, Yoda Y, Satake H. et al. Radial incision and cutting method for refractory stricture after nonsurgical treatment of esophageal cancer. Endoscopy 2013; 45: 316-319
  • 19 Minamino H, Machida H, Tominaga K. et al. Endoscopic radial incision and cutting method for refractory esophageal stricture after endoscopic submucosal dissection of superficial esophageal carcinoma. Dig Endosc 2013; 25: 200-203
  • 20 Nonaka K, Ban S, Aikawa M. et al. Electrocautery therapy combined with oral steroid administration for refractory corrosive esophageal stenosis prevents restenosis. Esophagus 2013; 10: 230-234
  • 21 Yuan X, Liu W, Ye L. et al. Combination of endoscopic incision and balloon dilation for treatment of a completely obstructed anastomotic stenosis following colorectal resection. Medicine (Baltimore) 2019; 98: e16292