Subscribe to RSS
DOI: 10.1055/a-2199-7155
Device-assisted enteroscopy performance measures in the United Kingdom: DEEP-UK quality improvement project
Abstract
Background Device-assisted enteroscopy (DAE) has become a well-established diagnostic and therapeutic tool for the management of small-bowel pathology. We aimed to evaluate the performance measures for DAE across the UK against the quality benchmarks proposed by the European Society of Gastrointestinal Endoscopy (ESGE).
Methods We retrospectively collected data on patient demographics and DAE performance measures from electronic endoscopy records of consecutive patients who underwent DAE for diagnostic and therapeutic purposes across 12 enteroscopy centers in the UK between January 2017 and December 2022.
Results A total of 2005 DAE procedures were performed in 1663 patients (median age 60 years; 53% men). Almost all procedures (98.1%) were performed for appropriate indications. Double-balloon enteroscopy was used for most procedures (82.0%), followed by single-balloon enteroscopy (17.2%) and spiral enteroscopy (0.7%). The estimated depth of insertion was documented in 73.4% of procedures. The overall diagnostic yield was 70.0%. Therapeutic interventions were performed in 42.6% of procedures, with a success rate of 96.6%. Overall, 78.0% of detected lesions were marked with a tattoo. Patient comfort was significantly better with the use of deep sedation compared with conscious sedation (99.7% vs. 68.5%; P<0.001). Major adverse events occurred in only 0.6% of procedures.
Conclusions Performance measures for DAE in the UK meet the ESGE quality benchmarks, with high diagnostic and therapeutic yields, and a low incidence of major adverse events. However, there is room for improvement in optimizing sedation practices, standardizing the depth of insertion documentation, and adopting marking techniques to aid in the follow-up of detected lesions.
Publication History
Received: 13 July 2023
Accepted after revision: 10 October 2023
Article published online:
10 November 2023
© 2023. Thieme. All rights reserved.
Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany
-
References
- 1 Pennazio M, Venezia L, Cortegoso Valdivia P. et al. Device-assisted enteroscopy: An update on techniques, clinical indications and safety. Dig Liver Dis 2019; 51: 934-943
- 2 Yamamoto H, Sekine Y, Sato Y. et al. Total enteroscopy with a nonsurgical steerable double-balloon method. Gastrointest Endosc 2001; 53: 216-220
- 3 Tsujikawa T, Saitoh Y, Andoh A. et al. Novel single-balloon enteroscopy for diagnosis and treatment of the small intestine: preliminary experiences. Endoscopy 2007; 40: 11-15 DOI: 10.1055/s-2007-966976. (PMID: 18058613)
- 4 Neuhaus H, Beyna T, Schneider M. et al. Novel motorized spiral enteroscopy: first clinical case. Gastrointest Endosc 2016; 83: AB637 DOI: 10.1016/j.vgie.2016.08.005. (PMID: 29905207)
- 5 Bisschops R, Areia M, Coron E. et al. Performance measures for upper gastrointestinal endoscopy: a European Society of Gastrointestinal Endoscopy (ESGE) Quality Improvement Initiative. Endoscopy 2016; 48: 843-864 DOI: 10.1055/s-0042-113128. (PMID: 27548885)
- 6 Kaminski MF, Thomas-Gibson S, Bugajski M. et al. Performance measures for lower gastrointestinal endoscopy: a European Society of Gastrointestinal Endoscopy (ESGE) Quality Improvement Initiative. Endoscopy 2017; 49: 378-397 DOI: 10.1177/2050640617700014. (PMID: 28507745)
- 7 Domagk D, Oppong KW, Aabakken L. et al. Performance measures for ERCP and endoscopic ultrasound: a European Society of Gastrointestinal Endoscopy (ESGE) Quality Improvement Initiative. Endoscopy 2018; 50: 1116-1127 DOI: 10.1055/a-0749-8767. (PMID: 30340220)
- 8 Spada C, McNamara D, Despott EJ. et al. Performance measures for small-bowel endoscopy: a European Society of Gastrointestinal Endoscopy (ESGE) Quality Improvement Initiative. Endoscopy 2019; 51: 574-598 DOI: 10.1177/2050640619850365. (PMID: 31210941)
- 9 Lee TJW, Siau K, Esmaily S. et al. Development of a national automated endoscopy database: The United Kingdom National Endoscopy Database (NED). United Eur Gastroenterol J 2019; 7: 798-806 DOI: 10.1177/2050640619841539. (PMID: 31316784)
- 10 Xin L, Liao Z, Jiang YP. et al. Indications, detectability, positive findings, total enteroscopy, and complications of diagnostic double-balloon endoscopy: A systematic review of data over the first decade of use. Gastrointest Endosc 2011; 74: 563-570 DOI: 10.1016/j.gie.2011.03.1239. (PMID: 21620401)
- 11 Lipka S, Rabbanifard R, Kumar A. et al. Single versus double balloon enteroscopy for small bowel diagnostics. J Clin Gastroenterol 2015; 49: 177-184 DOI: 10.1097/MCG.0000000000000274. (PMID: 25564409)
- 12 Wang P, Wang Y, Dong Y. et al. Outcomes and safety of double-balloon enteroscopy in small bowel diseases: a single-center experience of 1531 procedures. Surg Endosc 2021; 35: 576-583 DOI: 10.1007/s00464-020-07418-6. (PMID: 32072276)
- 13 Pinho R, Mascarenhas-Saraiva M, Mão-De-Ferro S. et al. Multicenter survey on the use of device-assisted enteroscopy in Portugal. United Eur Gastroenterol J 2016; 4: 264-274 DOI: 10.1177/2050640615604775. (PMID: 27087956)
- 14 Noujaim MG, Parish A, Raines D. et al. Use, yield, and risk of device-assisted enteroscopy in the United States. J Clin Gastroenterol 2021; 55: 792-797 DOI: 10.1097/MCG.0000000000001426. (PMID: 32947375)
- 15 Gomes A, Pinho R, Ponte A. et al. Analysis of performance measures in device assisted enteroscopy (DAE). Endoscopy 2020; 52: S65-S66
- 16 May A, Nachbar L, Schneider M. et al. Push-and-pull enteroscopy using the double-balloon technique: method of assessing depth of insertion and training of the enteroscopy technique using the Erlangen Endo-Trainer. Endoscopy 2005; 37: 66-70 DOI: 10.1055/s-2004-826177. (PMID: 15657861)
- 17 Albors O, Soria F, Cuadrado E. et al. Validity of insertion depth measurement in double-balloon endoscopy. Endoscopy 2012; 44: 1045-1050
- 18 Irvine AJ, Sanders DS, Hopper A. et al. How does tolerability of double balloon enteroscopy compare to other forms of endoscopy?. Frontline Gastroenterol 2016; 7: 41-46
- 19 Al-Toma A, Beaumont H, Koornstra JJ. et al. The performance and safety of motorized spiral enteroscopy, including in patients with surgically altered gastrointestinal anatomy: a multicenter prospective study. Endoscopy 2022; 54: 1034-1042
- 20 Chan W, Wei LK, Tan T. et al. Motorized spiral enteroscopy versus double-balloon enteroscopy: a case-matched study. Gastrointest Endosc 2023; 97: 314-324 DOI: 10.1016/j.gie.2022.09.030. (PMID: 36228697)
- 21 Yamamoto H, Despott EJ, González-Suárez B. et al. The evolving role of device-assisted enteroscopy: The state of the art as of August 2023. Best Pract Res Clin Gastroenterol 2023; 101858: 64-65
- 22 Gomes C, O’Neill C, Pinho R. et al. Critical analysis of the applicability of small bowel capsule endoscopy performance measures among 2 Portuguese centers with different capsule endoscopy platforms. GE Port J Gastroenterol 2023; 30: 230-238
- 23 Sint Nicolaas J, de Jonge V, de Man RA. et al. The Global Rating Scale in clinical practice: A comprehensive quality assurance programme for endoscopy departments. Dig Liver Dis 2012; 44: 919-924