CC BY-NC-ND 4.0 · Endosc Int Open 2024; 12(10): E1237-E1241
DOI: 10.1055/a-2427-2311
Innovation forum

Initial experience with transmural use of a new endoscopic ultrasound electric core needle biopsy device: Case series

1   Internal Medicine/Gastroenterology, UC Davis Medical Center, Sacramento, United States (Ringgold ID: RIN21772)
,
Amer Alsamman
1   Internal Medicine/Gastroenterology, UC Davis Medical Center, Sacramento, United States (Ringgold ID: RIN21772)
,
Karleen Meiklejohn
1   Internal Medicine/Gastroenterology, UC Davis Medical Center, Sacramento, United States (Ringgold ID: RIN21772)
,
Omar Viramontes
1   Internal Medicine/Gastroenterology, UC Davis Medical Center, Sacramento, United States (Ringgold ID: RIN21772)
› Author Affiliations
Zoom Image

Abstract

Background and study aims Endoscopic ultrasound-guided biopsy via fine-needle biopsy/fine-needle aspiration (FNB/FNA) is currently the standard method to sample tumors in the mediastinum and abdomen. Although specimens obtained with these needles are acceptable, a histological diagnosis is not always possible. Recently, a new EUS-guided core needle biopsy (EUS-CNB) device became available. Herein, we describe the first experience with its use in a transmural fashion.

Patients and methods This was a case series of patients who underwent EUS-CNB at an academic center. All patients provided written informed consent and were observed in the hospital ≥ 48 hours after the procedure.

Results A total of 8 patients underwent EUSC-CNB: five in the pancreas, two in the retroperitoneum, and one in the mediastinum. The diagnostic accuracy of EUS-CNB was 100% after one actuation. In four patients, same-session FNB and EUS-CNB were obtained from the same lesion with superior tissue sample in the latter. No adverse events were documented.

Conclusions To our knowledge this is the first report on transmural use of EUS-CNB in gastroenterology. Our findings suggest that the device is effective and safe. Larger studies comparing it with FNA/FNB needles will be required to further assess performance and safety.



Publication History

Received: 29 June 2024

Accepted after revision: 26 September 2024

Accepted Manuscript online:
30 September 2024

Article published online:
28 October 2024

© 2024. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/).

Georg Thieme Verlag KG
Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany