Eur J Pediatr Surg 2013; 23(02): 134-139
DOI: 10.1055/s-0032-1324800
Original Article
Georg Thieme Verlag KG Stuttgart · New York

Quantitative Software Analysis of Ultrasonographic Textures in Experimental Testicular Torsion

Mustafa Aslan
1   Department of Pediatric Surgery, Kirikkale University, Kirikkale, Turkey
,
Ibrahim Kucukaslan
2   Department of Obstetrics and Gynecology, Dicle University, Faculty of Veterinary Medicine, Diyarbakir, Turkey
,
Serkan Mulazimoglu
3   Technopolis - Hemosoft IT and Training Services Inc., Hacettepe University, Ankara, Turkey
,
Tutku Soyer
1   Department of Pediatric Surgery, Kirikkale University, Kirikkale, Turkey
,
Mine Şenyücel
4   Department of Pediatric Surgery, Guven Hospital, Ankara, Turkey
,
Murat Çakmak
5   Department of Pediatric Surgery, Ankara University, Ankara, Turkey
,
Jakob Scholbach
6   Department of Mathematics and Computer Sciences, Institute of Mathematics, Münster University, Münster, Germany
,
Selim Aslan
7   Department of Obstetrics and Gynecology, Ankara University, Faculty of Veterinary Medicine, Ankara, Turkey
› Institutsangaben
Weitere Informationen

Publikationsverlauf

25. Mai 2012

18. Juli 2012

Publikationsdatum:
23. Oktober 2012 (online)

Preview

Abstract

Aim Ultrasonography (US) has high diagnostic value in testicular torsion but is vulnerable to several potential errors, especially in the early period. Echotexture (ETX) analysis software provides a numerical expression of B-mode images and allows quantitative evaluation of blood flow due to ischemic damage using power Doppler US (PDUS) analysis. Our aim in this study was to determine the diagnostic value and effective parameters of EXT analysis software in the early period of torsion using B-mode and PDUS images.

Materials and Methods In this study, eight rats were used. Following anesthesia, the right testis was rotated to a 1080-degree counterclockwise position whereas the left testis was left in place to have a control group. B-mode and PDUS images of both sides were recorded with a portable US device immediately (0 hour) and 1 and 2 hours after torsion. The B-mode images were analyzed in terms of gradient, homogeneity, and contrast using the BS200pro software (BAB Digital Imaging System 2007, Ankara, Turkey). Intensity (I)-red and area (A)-red values were measured on PDUS images with the Pixelflux (Version 1.0, Chameleon-Software, Leipzig, Germany). The data were evaluated by the Mann–Whitney U and Wilcoxon tests.

Results Data from B-mode US image EXT analysis showed no significant difference between the right and left testicles in 0 to 2 hours (p > 0.05). The values obtained from PDUS analysis (I-red and A-red) significantly decreased at the testicular torsion side at the end of the second hour (p < 0.05). I-red and A-red values at 0 to 1 hour of torsion indicated similar blood flow alterations (p > 0.05) whereas the flow was significantly lower at 2 hours (p < 0.05).

Conclusion In experimental testicular torsion, ischemic changes can be detected by PDUS power/angio mode using blood flow alterations as early as the second hour. Tissue damage cannot be evaluated within the first 2 hours of torsion with B-mode ETX analysis.