Z Orthop Unfall 2015; 153(03): 317-320
DOI: 10.1055/s-0035-1545968
Aus den Sektionen – AE Deutsche Gesellschaft für Endoprothetik
Georg Thieme Verlag KG Stuttgart · New York

Intraoperative Analyse der Anatomie und Kinematik in der Knieendoprothetik

Intraoperative Evaluation of Total Knee Arthroplasty: Anatomic and Kinematic Assessment with Trial Components
P. von Roth
1   Centrum für Muskuloskeletale Chirurgie, Klinik für Orthopädie, Charité – Universitätsmedizin Berlin
2   Berlin-Brandenburg School for Regenerative Therapies, Charité – Universitätsmedizin Berlin
,
T. Pfitzner
1   Centrum für Muskuloskeletale Chirurgie, Klinik für Orthopädie, Charité – Universitätsmedizin Berlin
,
M. Fuchs
1   Centrum für Muskuloskeletale Chirurgie, Klinik für Orthopädie, Charité – Universitätsmedizin Berlin
,
C. Perka
1   Centrum für Muskuloskeletale Chirurgie, Klinik für Orthopädie, Charité – Universitätsmedizin Berlin
› Author Affiliations
Further Information

Publication History

Publication Date:
26 June 2015 (online)

Zusammenfassung

Durch die Verwendung von Probekomponenten kann in der Knieendoprothetik eine fehlerhafte knöcherne Resektion und Einstellung der ligamentären Strukturen erkannt und vermieden werden. Diese Arbeit stellt einen 8-Punkte-Algorithmus vor, um vor der Implantation der definitiven Implantate die Wiederherstellung der Anatomie und Kinematik zu überprüfen. Für die Beurteilung der Anatomie sollte neben der Größe und Passform der Komponenten auch die Rotation bestimmt bzw. überprüft werden. Die femorale Rotation wird mittels der Epikondylenachse kontrolliert. Die tibiale Rotation wird anhand knöcherner Landmarken wie der Tuberositas tibiae ausgerichtet. Patellarseitig kann überstehender Knochen („uncovered bone“) identifiziert und entfernt werden. Für die Wiederherstellung einer möglichst physiologischen Kinematik sollte die Gelenklinie exakt rekonstruiert werden. Hierfür stellt die Basis der resezierten Menisken eine hilfreiche Referenz dar. Ein zu enger Streckspalt fällt durch eine eingeschränkte Streckfähigkeit auf. Ein zu enger bzw. unbalancierter Beugespalt zeigt sich durch das sog. „booking“ bzw. „spin-out“ des Inlays sowie das Abheben der femoralen Probekomponente vom Knochen. Mit dem POLO-Test (pull-out, lift-off) lässt sich die Spannung des hinteren Kreuzbands und die Weite des Beugespalts kontrollieren. Über spezifische Tests lassen sich die korrekte Positionierung, der Lauf und das „overstuffing“ der Patellakomponente überprüfen. Der vorgestellte 8-Punkte-Algorithmus nutzt die Probeteile, um noch vor endgültiger Fixation der Komponenten die Anatomie und Kinematik zu überprüfen, Fehler zu visualisieren und Feineinstellungen in Position und Weichteilbalancierung vornehmen zu können.

Abstract

The intraoperative use of trial components in total knee arthroplasty (TKA) is of paramount importance to prevent inadequate ligament balance and to achieve optimal position of the definitive components. This review demonstrates an 8-step algorithm to assess the anatomy of the femoral, tibial and patellar component as well as the kinematics of the tibiofemoral and patellofemoral joints. Trial components allow an easy assessment of the anatomic fit of the final implants. Upon the trials insertion, bone coverage and the component overhang should be evaluated. The femoral rotation should be assessed using the transepicondylar axis and for the tibial component rotation assessment, the tibial tuberosity would be the most reliable bony landmark. Addressing the patella, sizing and bone coverage should be thoroughly evaluated. In order to restore physiological kinematics the remnants of the meniscus rim can be used to determine the correct reconstruction of the joint line. A tight extension gap results in limited extension, whereas a tight or unbalanced flexion gap leads to “booking” or “spin-out” of the inlay. The POLO test (pull-out, lift- off) allows an easy assessment of the posterior cruciate ligament tension and the size of the flexion gap as well. To prevent postoperative dislocation and overstuffing, specific tests for correct patellar positioning and tracking support should be performed. The anatomy and kinematics of total knee arthroplasty have to be evaluated by trial components on a routine basis before inserting the final implants in order to identify implant positioning errors and inadequate ligament balance.

 
  • Literatur

  • 1 Carr AJ, Robertsson O, Graves S et al. Knee replacement. Lancet 2012; 379: 1331-1340
  • 2 Pfitzner T, von Roth P, Perka C et al. Intramedullary control of distal femoral resection results in precise coronal alignment in TKA. Arch Orthop Trauma Surg 2014; 134: 459-465
  • 3 Bieger R, Huch K, Kocak S et al. The influence of joint line restoration on the results of revision total knee arthroplasty: comparison between distance and ratio-methods. Arch Orthop Trauma Surg 2014; 134: 537-541
  • 4 Scuderi GR, Insall JN. Rotational positioning of the femoral component in total knee arthroplasty. Am J Knee Surg 2000; 13: 159-161
  • 5 Bellemans J. Neutral mechanical alignment: a requirement for successful TKA: opposes. Orthopedics 2011; 34: e507-509
  • 6 Clary C, Aram L, Deffenbaugh D et al. Tibial base design and patient morphology affecting tibial coverage and rotational alignment after total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 2014; 22: 3012-3018
  • 7 Lutzner J, Krummenauer F, Gunther KP et al. Rotational alignment of the tibial component in total knee arthroplasty is better at the medial third of tibial tuberosity than at the medial border. BMC Musculoskelet Disord 2010; 11: 57
  • 8 Shetty GM, Mullaji A, Bhayde S. Computer guided restoration of joint line and femoral offset in cruciate substituting total knee arthroplasty. Knee 2012; 19: 611-616
  • 9 Snider MG, Macdonald SJ. The influence of the posterior cruciate ligament and component design on joint line position after primary total knee arthroplasty. J Arthroplasty 2009; 24: 1093-1098
  • 10 Matziolis G, Perka C. Primary resection of the posterior cruciate ligament does not produce a gap mismatch in the navigated gap technique. Orthopedics 2010; 33: 68-70
  • 11 Baldini A, Scuderi GR, Aglietti P et al. Flexion-extension gap changes during total knee arthroplasty: effect of posterior cruciate ligament and posterior osteophytes removal. J Knee Surg 2004; 17: 69-72
  • 12 Ritter MA, Faris PM, Keating EM. Posterior cruciate ligament balancing during total knee arthroplasty. J Arthroplasty 1988; 3: 323-326
  • 13 Scott RD, Chmell MJ. Balancing the posterior cruciate ligament during cruciate-retaining fixed and mobile-bearing total knee arthroplasty: description of the pull-out lift-off and slide-back tests. J Arthroplasty 2008; 23: 605-608
  • 14 Arabori M, Matsui N, Kuroda R et al. Posterior condylar offset and flexion in posterior cruciate-retaining and posterior stabilized TKA. J Orthop Sci 2008; 13: 46-50
  • 15 Victor J, Bellemans J. Physiologic kinematics as a concept for better flexion in TKA. Clin Orthop Relat Res 2006; 452: 53-58
  • 16 Goyal N, Matar WY, Parvizi J. Assessing patellar tracking during total knee arthroplasty: a technical note. Am J Orthop (Belle Mead NJ) 2012; 41: 450-451