J Hand Microsurg 2016; 08(03): 159-164
DOI: 10.1055/s-0036-1593730
Original Article
Thieme Medical and Scientific Publishers Private Ltd.

The Use of Minilocked Plate for Management of Unstable Metacarpal Fractures

Ahmed Mohammed AL-Madawy
1   Hand Unit, Alrazi Hospital, State of Kuwait, Kuwait
,
Mohamed Mahmoud Abou Elatta
1   Hand Unit, Alrazi Hospital, State of Kuwait, Kuwait
,
Mostafa Mahmoud Hasanin
2   Department of Medicine, Cairo University, Giza, Egypt
,
Ashraf Abd El-Kader Al-Nahal
2   Department of Medicine, Cairo University, Giza, Egypt
› Author Affiliations
Further Information

Publication History

06 April 2016

05 September 2016

Publication Date:
14 October 2016 (online)

Abstract

Objective This study aims to evaluate the use of minilocked plates in the treatment of the metacarpal fractures.

Method A total of 30 patients of metacarpal fractures were treated by minilocked plates.

Results Union was achieved in all patients. There were 27 (90%) patients having satisfactory results (excellent and good results) and 3 patients (10%) had poor results.

Conclusion The use of minilocked plate is recommended for fixation of periarticular, comminuted, and osteoporotic metacarpal fractures that offer rigid fixation early mobilization, decreases the incidence of joints stiffness, and tendon adherence which maximized the hand function.

Note

This research received no specific grant from any funding agency in the public, commercial, or not-for-profit sectors.


 
  • References

  • 1 McNemar TB, Howell JW, Chang E. Management of metacarpal fractures. J Hand Ther 2003; 16 (2) 143-151
  • 2 de Jonge JJ, Kingma J, van der Lei B, Klasen HJ. Fractures of the metacarpals. A retrospective analysis of incidence and aetiology and a review of the English-language literature. Injury 1994; 25 (6) 365-369
  • 3 Day CS, Stern PJ. Fractures of metacarpals and phalanges. In: Wolfe SW, Pederson WC, Hotchkiss RN, Kozin SH, Cohen MS, eds. Green's Operative Hand Surgery. 6th ed. Philadelphia, PA: Elsevier Churchill Living stone; 2010: 239-290
  • 4 Strauch RJ, Rosenwasser MP, Lunt JG. Metacarpal shaft fractures: the effect of shortening on the extensor tendon mechanism. J Hand Surg Am 1998; 23 (3) 519-523
  • 5 Meunier MJ, Hentzen E, Ryan M, Shin AY, Lieber RL. Predicted effects of metacarpal shortening on interosseous muscle function. J Hand Surg Am 2004; 29 (4) 689-693
  • 6 Kozin SH, Thoder JJ, Lieberman G. Operative treatment of metacarpal and phalangeal shaft fractures. J Am Acad Orthop Surg 2000; 8 (2) 111-121
  • 7 Jabaley ME, Freeland AE. Rigid internal fixation in the hand: 104 cases. Plast Reconstr Surg 1986; 77 (2) 288-298
  • 8 Gonzalez MH, Igram CM, Hall Jr RF. Flexible intramedullary nailing for metacarpal fractures. J Hand Surg Am 1995; 20 (3) 382-387
  • 9 Lister G. Intraosseous wiring of the digital skeleton. J Hand Surg Am 1978; 3 (5) 427-435
  • 10 Salom M, Aroca JE, Chover V, Alonso R, Vilar R. Distraction-lengthening of digital rays using a small external fixator. J Hand Surg [Br] 1998; 23 (6) 781-784
  • 11 Jupiter JB, Koniuch MP, Smith RJ. The management of delayed union and nonunion of the metacarpals and phalanges. J Hand Surg Am 1985; 10 (4) 457-466
  • 12 Weiss AP, Hastings II H. Distal unicondylar fractures of the proximal phalanx. J Hand Surg Am 1993; 18 (4) 594-599
  • 13 Hall Jr RF. Treatment of metacarpal and phalangeal fractures in noncompliant patients. Clin Orthop Relat Res 1987; (214) 31-36
  • 14 Freeland AE, Geissler WB, Weiss AP. Operative treatment of common displaced and unstable fractures of the hand. J Bone Joint Surg Am 2001; 83: 928-945
  • 15 Dabezies EJ, Schutte JP. Fixation of metacarpal and phalangeal fractures with miniature plates and screws. J Hand Surg Am 1986; 11 (2) 283-288
  • 16 Haidukewych GJ. Innovations in locking plate technology. J Am Acad Orthop Surg 2004; 12 (4) 205-212
  • 17 Belsky MR, Eaton RG, Lane LB. Closed reduction and internal fixation of proximal phalangeal fractures. J Hand Surg Am 1984; 9 (5) 725-729
  • 18 Kilbourne BC, Paul EG. The use of small bone screws in the treatment of metacarpal, metatarsal, and phalangeal fractures. J Bone Joint Surg Am 1958; 40-A (2) 375-383
  • 19 Prevel CD, Eppley BL, Jackson JR , et al. Mini and micro plating of phalangeal and metacarpal fractures: a biomechanical study. J Hand Surg Am 1995; 20 (1) 44-49
  • 20 Curtis BD, Fajolu O, Ruff ME, Litsky AS. Fixation of metacarpal shaft Fractures: Biomechanical comparison of intramedullary nail, crossed K-wires and plate-screw constructs. Orthop Surg 2015; 7 (3) 256-260
  • 21 Freeland AE, Orbay JL. Extraarticular hand fractures in adults: a review of new developments. Clin Orthop Relat Res 2006; (445) 133-145
  • 22 Ochman S, Doht S, Paletta J, Langer M, Raschke MJ, Meffert RH. Comparison between locking and non-locking plates for fixation of metacarpal fractures in an animal model. J Hand Surg Am 2010; 35 (4) 597-603
  • 23 Barr C, Behn AW, Yao J. Plating of metacarpal fractures with locked or nonlocked screws, a biomechanical study: how many cortices are really necessary?. Hand (NY) 2013; 8 (4) 454-459
  • 24 Smith WR, Ziran BH, Anglen JO, Stahel PF. Locking plates: tips and tricks. J Bone Joint Surg Am 2007; 89 (10) 2298-2307
  • 25 Diwaker HN, Stothard J. The role of internal fixation in closed fractures of the proximal phalanges and metacarpals in adults. J Hand Surg [Br] 1986; 11 (1) 103-108
  • 26 Ozer K, Gillani S, Williams A, Peterson SL, Morgan S. Comparison of intramedullary nailing versus plate-screw fixation of extra-articular metacarpal fractures. J Hand Surg Am 2008; 33 (10) 1724-1731
  • 27 Puckett CL, Welsh CF, Croll GH, Concannon MJ. Application of maxillofacial miniplating and microplating systems to the hand. Plast Reconstr Surg 1993; 92 (4) 699-707 , discussion 708–709
  • 28 Ford DJ, el-Hadidi S, Lunn PG, Burke FD. Fractures of the metacarpals: treatment by A. O. screw and plate fixation. J Hand Surg [Br] 1987; 12 (1) 34-37
  • 29 Barton NJ. Fractures of the shafts of the phalanges of the hand. Hand 1979; 11 (2) 119-133
  • 30 Crawford GP. Screw fixation for certain fractures of the phalanges and metacarpals. J Bone Joint Surg Am 1976; 58 (4) 487-492
  • 31 Stern PJ, Wieser MJ, Reilly DG. Complications of plate fixation in the hand skeleton. Clin Orthop Relat Res 1987; (214) 59-65
  • 32 Absoud EM, Harrop SN. Hand injuries at work. J Hand Surg [Br] 1984; 9 (2) 211-215
  • 33 Grundberg AB. Intramedullary fixation for fractures of the hand. J Hand Surg Am 1981; 6 (6) 568-573
  • 34 Page SM, Stern PJ. Complications and range of motion following plate fixation of metacarpal and phalangeal fractures. J Hand Surg Am 1998; 23 (5) 827-832
  • 35 Brown PW. The management of phalangeal and metacarpal fractures. Surg Clin North Am 1973; 53 (6) 1393-1437
  • 36 Ruchelsman DE, Mudgal CS, Jupiter JB. The role of locking technology in the hand. Hand Clin 2010; 26 (3) 307-319, v