Zusammenfassung

Fragestellung: In der vorliegenden Arbeit wurde untersucht, ob der Korrelationsindex (VAFI) aus den Stromzeitvolumina der Vena und Arteria femoralis communis über 40 min Liegezeit stabil bleibt.

Methode: 63 Patienten wurden in 3 Kollektive eingeteilt: 20 Venengesunde (Kollektiv 1), 23 Patienten mit primärer Stammvarikosis (Kollektiv 2) und 20 Patienten mit postthrombotischem Syndrom (PTS) (Kollektiv 3). Über einen Untersuchungszeitraum von 40 min wurde duplexsonographisch in 10-minütigen Abständen unter standardisierten Messbedingungen der VAFI bestimmt.

Ergebnisse: Der VAFI blieb in allen drei Kollektiven über den gesamten Messzeitraum konstant. Der Mittelwert der venengesunden Patienten betrug 0,898, jener der Patienten mit Stammvarikosis 1,338 und der bei den Patienten mit PTS 1,402. Dabei unterschieden sich die Ergebnisse der Venengesunden von denen der beiden anderen Kollektive zu sämtlichen Untersuchungszeitpunkten signifikant (p < 0,005).

Schlussfolgerung: Der Korrelationsindex (VAFI) bleibt über einen längeren Untersuchungszeitraum stabil und eignet sich zur quantitativen Erfassung von venösen Abflussstörungen bei Patienten mit venösen Erkrankungen.

Summary

Aim: The aim of this study was to investigate whether the correlation index, VAFI, remains stable over a period of 40 min in three different collectives. The VAFI equals the volume flow in the common femoral vein divided by the volume flow in the common arterial vein.

Method: 63 patients in total were examined. Of these, 20 had no venous disorder (collective 1), 23 had primary varicosis (collective 2), and 20 had been diagnosed with postthrombotic syndrome (collective 3). The VAFI was measured every 10 min over a period of 40 min under standardized conditions.

Results: The VAFI remained stable in all 3 collectives over the 40 min period. The mean for collective 1 was 0.898, for collective 2 1.338, and for collective 3 1.402. The difference between collective 1 and collectives 2 and 3 was significant (p < 0.005).

Conclusion: The correlation index (VAFI) remains stable over a longer period of time and is a suitable method for quantifying venous insufficiency.

Résumé

L´ objet: Examiner si l´index (VAFI), qui se calcule en divisant le flux volume dans la veine et l‘artère femorale commune, reste stable sur une periode d´ examination de 40 min.

Méthode: 63 sujets ont été examinés. 20 patients sans signes d´une maladie veineuse (groupe 1), 23 patients avec une varicose primaire (groupe 2), 20 patients avec un syndrome postthrombotique (groupe 3). Sur une periode de 40 min, on a examiné les patients tous les 10 min sous des conditions de standard.

Résultats: L´ index est resté stable dans tous les trois collectives sur les 40 min. Le moyen du groupe 1 était 0,898, en groupe 2 il était 1,338 et en groupe 3 il était 1,402. Les resultats en groupe 1 d´un côté et groupes 2 et 3 de l´autre côté étaient significativement différents (p < 0,005).

Conclusion: L´ index (VAFI) reste stable sur une longue periode de temps et il est une méthode idéale pour quantifier une insuffisance veineuse.

Est-ce que l’index de correlation de flux volume de la veine et l’artère femorale commune (VAFI) reste stable sur une longe periode de temps?

* Diese Arbeit ist Herrn Prof. Dr.D. Petzoldt zu seinem 65. Geburtstag gewidmet.