Zahnmedizin up2date, Table of Contents Zahnmedizin up2date 2016; 10(04): 327-355DOI: 10.1055/s-0042-101842 Endodontologie Georg Thieme Verlag KG Stuttgart · New York Die digitale Volumentomografie (DVT) in der Endodontologie Karl Dula , Franziska Kissling-Jeger , Klaus W. Neuhaus Recommend Article Abstract Buy Article All articles of this category Full Text References Literatur 1 Mozzo P, Procacci C, Tacconi A et al. A new volumetric CT machine for dental imaging based on the cone-beam technique: preliminary results. Eur Radiol 1998; 8: 1558-1564 2 Pauwels R, Beinsberger J, Collaert B et al. Effective dose range for dental cone beam computed tomography scanners. Eur J Radiol 2012; 81: 267-271 3 Ludlow JB, Timothy R, Walker C et al. Effective dose of dental CBCT – a meta analysis of published data and additional data for nine CBCT units. Dentomaxillofac Radiol 2015; 44: 20140197 4 Ludlow JB, Ivanovic M. Comparative dosimetry of dental CBCT devices and 64-slice CT for oral and maxillofacial radiology. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2008; 106: 106-114 5 Committee to Assess Health Risks from Exposure to Low Levels of Ionizing Radiation. BEIR VII – Phase 2. Washington DC: National Research Council; 2006 6 Dula K, Mini R, van der Stelt PF et al. The radiographic assessment of implant patients: decision-making criteria. Int J Oral Maxillofac Implants 2001; 16: 80-89 7 Dula K, Mini R, van der Stelt PF et al. Hypothetical mortality risk associated with spiral computed tomography of the maxilla and mandible. Eur J Oral Sci 1996; 104: 503-510 8 United Nations Publications. United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) 2013 Report: Effects of Radiation Exposure of Children. Supplement No. 46. New York: United Nations; 2013 9 Liang X, Jacobs R, Hassan B et al. A comparative evaluation of Cone Beam Computed Tomography (CBCT) and Multi-Slice CT (MSCT). Part I. On subjective image quality. Eur J Radiol 2010; 75: 265-269 10 Dula K, Buser D, Porcellini B et al. Computertomographie/Orale Implantologie. Dental-CT: Ein Programm zur computertomographischen Darstellung der Kiefer: Grundlagen und Aufnahmetechnik. Schweiz Monatsschr Zahnmed 1994; 104: 451-456 11 AAE and AAOMR Joint Position Statement: Use of cone beam computed tomography in endodontics 2015 update. Oral Surg Oral Med Oral Pathol Oral Radiol 2015; 4: 508-512 12 Patel S, Durack C, Abella F et al. Cone beam computed tomography in endodontics – a review. Int Endod J 2015; 48: 3-15 13 Dula K, Benic GI, Bornstein M et al. SADMFR guidelines for the use of cone-beam computed tomography/digital volume tomography – endodontics, periodontology, reconstructive dentistry, pediatric dentistry. Swiss Dent J 2015; 125: 945-953 14 European Commission. Radiation Protection N°172: Evidence based guidelines on cone beam CT for dental and maxillofacial radiology. Luxembourg: Office for official publications of the European communities; 2012 15 Jeger FB, Lussi A, Bornstein MM et al. Die digitale Volumentomografie in der Endodontologie: Eine Übersicht für den Praxisalltag. Schweiz Monatsschr Zahnmed 2013; 123: 661-668 16 Janner SF, Jeger FB, Lussi A, Bornstein MM. Precision of endodontic working length measurements: a pilot investigation comparing cone-beam computed tomography scanning with standard measurement techniques. J Endod 2011; 37: 1046-1051 17 Jeger FB, Janner SF, Bornstein MM et al. Endodontic working length measurement with preexisting cone-beam computed tomography scanning: a prospective, controlled clinical study. J Endod 2012; 38: 884-888 18 Estrela C, Bueno MR, Sousa-Neto MD et al. Method for determination of root curvature radius using cone-beam computed tomography images. Braz Dent J 2008; 19: 114-118 19 Michetti J, Maret D, Mallet JP et al. Validation of cone beam computed tomography as a tool to explore root canal anatomy. J Endod 2010; 36: 1187-1190 20 Krastl G, Zehnder MS, Connert T et al. Guided endodontics: a novel treatment approach for teeth with pulp canal calcification and apical pathology. Dent Traumatol 2015; 21 Perrin P, Neuhaus KW, Lussi A. The impact of loupes and microscopes on vision in endodontics. Int Endod J 2014; 47: 425-429 22 DIN 6868-161: Sicherung der Bildqualität in röntgendiagnostischen Betrieben – Teil 161: Abnahmeprüfung nach RöV an zahnmedizinischen Röntgeneinrichtungen zur digitalen Volumentomografie. Berlin: Beuth; 2013 23 Wu MK, Shemesh H, Wesselink PR. Limitations of previously published systematic reviews evaluating the outcome of endodontic treatment. Int Endod J 2009; 42: 656-666 24 Lofthag-Hansen S, Huumonen S, Gröndahl K et al. Limited cone-beam CT and intraoral radiography for the diagnosis of periapical pathology. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2007; 103: 114-119 25 Low KM, Dula K, Burgin W et al. Comparison of periapical radiography and limited cone-beam tomography in posterior maxillary teeth referred for apical surgery. J Endod 2008; 34: 557-562 26 Bornstein MM, Lauber R, Sendi P et al. Comparison of periapical radiography and limited cone-beam computed tomography in mandibular molars for analysis of anatomical landmarks before apical surgery. J Endod 2011; 37: 151-157 27 Weissman J, Johnson JD, Anderson M et al. Association between the presence of apical periodontitis and clinical symptoms in endodontic patients using cone-beam computed tomography and periapical radiographs. J Endod 2015; 41: 1824-1829 28 Janner SF, Caversaccio MD, Dubach P et al. Characteristics and dimensions of the Schneiderian membrane: a radiographic analysis using cone beam computed tomography in patients referred for dental implant surgery in the posterior maxilla. Clin Oral Implants Res 2011; 22: 1446-1453 29 Bornstein MM, Bingisser AC, Reichart PA et al. Comparison between radiographic (2-dimensional and 3-dimensional) and histologic findings of periapical lesions treated with apical surgery. J Endod 2015; 41: 804-811 30 Pigg M. Chronic intraoral pain assessment of diagnostic methods and prognosis. Swed Dent J Suppl 2011; 7-91 31 Pasqualini D, Scotti N, Ambrogio P et al. Atypical facial pain related to apical fenestration and overfilling. Int Endod J 2012; 45: 670-677 32 Polycarpou N, Ng YL, Canavan D et al. Prevalence of persistent pain after endodontic treatment and factors affecting its occurrence in cases with complete radiographic healing. Int Endod J 2005; 38: 169-178 33 Kamburoglu K, Kursin S. A comparison of the diagnostic accuracy of CBCT images of different voxel resolutions used to detect simulated small internal resorption cavities. Int Endod J 2010; 43: 798-807 34 Heithersay GS. Invasive cervical resorption: an analysis of potential predisposing factors. Quintessence Int 1999; 30: 83-89 35 Von Arx T, Schawalder P, Ackermann M et al. Human and feline invasive cervical resorptions: the missing link? Presentation of four cases. J Endod 2009; 35: 904-913 36 Cohenca N, Simon JH, Roges R et al. Clinical indications for digital imaging in dento-alveolar trauma. Part 1: traumatic injuries. Dental Traumatol 2007; 23: 95-104 37 Dula K, Bornstein MM, Buser D et al. SADMFR guidelines for the use of cone-beam computed tomography/digital volume tomography – oral and maxillofacial surgery, temporomandibular joint disorders and orthodontics. Swiss Dent J 2014; 124: 1170-1183