RSS-Feed abonnieren
DOI: 10.1055/s-2000-11569
Influence of Orthotopic Heart Transplantation on Breathing Pattern Disorders in Patients with Dilated Cardiomyopathy
Publikationsverlauf
Publikationsdatum:
31. Dezember 2000 (online)

ABSTRACT
Cheyne-Stokes respiration is well-known in patients with congestive heart failure. One of the causes might be a prolonged circulation time or diminished pulmonary gas stores. Improvement of cardiac function by heart transplantation might abolish Cheyne-Stokes respiration. We examined 29 male patients (age 24 to 63 years) with polysomnographically verified Cheyne-Stokes respiration before and 3 to 9 weeks after orthotopic heart transplantation. All patients suffered from congestive heart disease. Left ventricular ejection fraction (LVEF) was between 8 and 19%. We analyzed sleep stages, respiratory events, oxygen saturation, and cardiac function (echocardiography and ergometry). Before heart transplantation all patients showed periodic breathing (apnea-hypopnea index [AHI] 13.2-51.6/h). Oxygen saturation dropped to a minimum of 63%. Sleep was severely disturbed. After heart transplantation LVEF was significantly higher in all patients (xmean = 64%). Twenty-three of 29 patients showed no more evidence of periodic breathing. However, even with normalized cardiac function, 6 patients still suffered from Cheyne-Stokes respiration. Cheyne-Stokes respiration is often associated with dilated cardiomyopathy. Our results demonstrate that normalization of cardiac function improves Cheyne-Stokes respiration. Even after normalization of cardiac function, some patients suffer from Cheyne-Stokes respiration further on. We suggest that breathing control centers may be permanently damaged in these patients.
KEYWORD
Cheyne-Stokes respiration - dilated cardiomyopathy - congestive heart failure - heart transplantation
REFERENCES
- 1 Javaheri S, Parker T J, Liming J D. Sleep apnea in 81 ambulatory male patients with stable heart failure. Circulation . 1998; 97 2154-2159
- 2 Yamashiro Y, Kryger M H. Sleep in heart failure. Sleep . 1993; 16 513-523
- 3 Lieber C V, Mohsenin V. Cheyne-Stokes respiration in congestive heart failure. Yale J Biol Med . 1992; 65 39-50
- 4 Douglas G S, Haldane J S. The causes of periodic or Cheyne-Stokes breathing. J Physiol . 1909; 38 401-419
- 5 Crabb J E, Pingleton S K, Gollub S. Sleep disordered breathing (SDB) in decompensated and compensated congestive heart failure [abstract]. Am Rev Respir Dis . 1985; 131 A104
- 6 Baylor P, Taylor D, Owen D, Sanders C. Cardiac failure presenting as sleep apnea. Elimination of apnea following medical management of cardiac failure. Chest . 1988; 94 1298-1300
- 7 Dark D S, Pingleton S K, Kerby G R. Breathing pattern abnormalities and arterial oxygen desaturation during sleep in the congestive heart failure syndrome. Chest . 1987; 91 833-836
- 8 Klink M E, Sethi G K, Copeland J G, Quan S F. Obstructive sleep apnea in heart transplantation patients: A report of five cases. Chest . 1993; 104 1090-1092
- 9 Collop N A. Cheyne-Stokes respiration-Stokes ventilation converting to obstructive sleep apnea following heart transplantation. Chest . 1993; 104 1288-1289
- 10 Andreas S, Mohr F W, Kreuzer H. Elimination der periodischen Atmung bei Herzinsuffizienz durch Herztransplantation. Pneumologie . 1995; 49 428-430
- 11 Weil J V, Kryger M H, Scoggin C. Sleep and breathing at high altitude. In: Guilleminault CW, Dement C, eds. Sleep Apnea Syndomes New York:Alan R. Liss 1978: 119-135
- 12 Bradley T D, Holloway R M, McLaughin P R, Ross B L, Walters J, Liu P P. Cardiac output response to continous positive airway pressure in congestive heart failure. Am Rev Respir Dis . 1992; 145 377-382
- 13 Reed J W, Ablett M, Cotes J E. Ventilatory responses to exercises and to carbon dioxide in mitral stenosis before and after valvulotomy: causes of tachypnoea. Clin Sci Mol Med . 1978; 54 9-15
- 14 Steens R D, Biberdorf D, Buckle P, Ahmed M, Millar T, Kryger M H. Effect of inhaled 3% CO2 on Cheyne-Stokes respiration in congestive heart failure [abstract]. Am Rev Respir Dis . 1992; 145 A4451