Osteosynthesis and Trauma Care 2003; 11(1): 21-23
DOI: 10.1055/s-2003-40117
Original Article

© Georg Thieme Verlag Stuttgart · New York

Temporary External Fixation of Femur Fractures: New Half Frame Applications with the “Tower Pin” Augmentations

N. Schettler1 , J. Ogden1 , D. Seligson1
  • 1Department of Orthopedic Surgery, University of Louisville, Louisville, KY, USA
Further Information

Publication History

Publication Date:
20 June 2003 (online)

Abstract

A case history is presented involving management of a comminuted femur fracture with the Hoffmann Monotube System and the “tower pin” augmentation used for external fixation. This new method of external fixation provides all the advantages of external fixation in comparison with internal fixation for cases of critically injured patients or injuries with severe soft tissue damage. By utilizing the “tower pin” augmentation the fracture is stable in all planes. Use of the device as an available alternative is advocated based on this preliminary experience. We recommend the conversion from external fixation to intramedullary nailing after improvement of the soft tissue injury or stabilization of the patient.

References

  • 1 Boltze W H, Fernandez D L, Schatzker J. The External Fixator (Tubular system). Swiss Association for Study of Internal Fixation 1976
  • 2 Brien W W, Kuschner S H, Brien E W, Wiss D A. The management of gunshot wounds to the femur.  Othop Clin North Am. 1995;  26 133-138
  • 3 Höntzsch D, Weise K, Weller S. Verfahrenswechsel vom Fixateur externe zur Marknagelosteosynthese an Femur und Tibia.  Trauma und Berufskrankheit. 2000;  2 101-110
  • 4 Nowotarski P J, Turen C H, Brumback R J, Scarboro J M. Conversion of external fixation to intramedullary nailing for fractures of the shaft of the femur in multiply injured patients.  J Bone Joint Surg [Am]. 2000;  82 781-788
  • 5 Pfeil J (ed). Heidelberg External Fixation. Thieme, Stuttgart 1998
  • 6 Rennirt G, Seligson D. One-stage intramedullary nailing.  Osteo Int. 1993;  2 84-88
  • 7 Rooser B, Bengtson S, Herrlin K, Onnerfalt R. External fixation of femoral fractures: experience with 15 cases.  J Orthop Trauma. 1990;  4 70-74
  • 8 Scalea T M, Boswell S A, Scott J D, Mitchell K A, Kramer M E, Pollak A N. External fixation as a bridge to intramedullary nailing for patients with multiple injuries and with femur fractures: damage control orthopedics.  J Trauma. 2000;  48 613-623
  • 9 Seligson D, Dudey D. Historical introduction. In: Seligson D, Pope M (eds). Concepts in External Fixation Grune & Stratton, New York 1982; 3-12
  • 10 Seligson D, Howard P A, Givens R. Sekundäre Marknagelung nach Fixateur externe - Stabilisierung von Femurschaftfrakturen. In: Wolter D, Hansis M, Havemann D (eds). Externe und interne Fixateursysteme. Springer, Berlin, Heidelberg 1995; 143-145
  • 11 Seligson D, Kristiansen T K. Use of the Wagner apparatus in complicated fractures the distal femur.  J Trauma. 1978;  18 795-799
  • 12 Tejan J, Lindsey R W. Management of civilian gunshot injuries of the femur. A review of the literature.  Injury. 1998;  29 18-22
  • 13 Van den Bossche M R, Broos P L, Rommens P M. Open fractures of the femoral shaft, treated with osteosynthesis or temporary external fixation.  Injury. 1995;  26 323-325

N. Schettler M.D. 

Department of Orthopedic Surgery, University of Louisville

530 South Jackson Street

Louisville, KY 40202 · USA

Phone: +15 02/8 52-53 19

Fax: +15 02/8 52-72 27