Endoscopy 2005; 37(11): 1094-1097
DOI: 10.1055/s-2005-870532
DDW Highlights
© Georg Thieme Verlag KG Stuttgart · New York

Colon Tumours and Colonoscopy

B.  P.  Saunders1
  • 1Wolfson Unit for Endoscopy, St. Mark’s Hospital, London, United Kingdom
Further Information

Publication History

Publication Date:
10 November 2005 (online)

Introduction

Colonoscopic practice continues to be a major theme of Digestive Disease Week. At this year’s meeting, radical new colonoscope designs were described for the first time, and there was a particular emphasis on initial evaluations of new optical detection technologies. The quality of colonoscopy, in terms of insertion and examination during withdrawal, was an important topic, as was the increasing potential of therapeutic colonoscopy. Japanese researchers were again seen to be leading the way in pushing back the boundaries of endoscopic polyp detection and early cancer resection.

References

  • 1 Fireman Z, Jacob H, Eliakim A, Goldfarb-Albak S. Innovative technology facilitates colonoscope disinfection: ColonSight® Intrapull™ power assisted disposable technology isolates infectious agents from physician, nurse and patient, no high level disinfection (HLD) necessary between procedures.  DDW Abstract. 2005;  S1095
  • 2 Swain P, Mills T, Kelleher B. et al . Radiocontrolled movement of a robot endoscope in the human gastrointestinal tract.  DDW Abstract. 2005;  599
  • 3 VanDam J, Jakobs R. Evaluation of a new partially-automated, potentially sedationless colonoscope.  DDW Abstract. 2005;  562
  • 4 Pfeffer J, Arber N, Halpern Z. Aer-O-Scope: self-propelling self-navigating skill-independent colonoscopy; a new era in screening colonoscopy.  DDW Abstract. 2005;  90
  • 5 Pasricha P J, Haber G. The ShapeLock™ endoscopic guide facilitates successful colonoscopies after previously failed attempts in difficult cases.  DDW Abstract. 2005;  W1144
  • 6 Takahashi M, Oka S, Takada H, Kuwayama H. Colonoscope position detecting system’s impact on patient-based comfort and efficiency of colonoscopy.  DDW Abstract. 2005;  W1152
  • 7 Dar S, Despott E, Murray I, Dalton H. Impact of magnetic endoscope imaging.  DDW Abstract. 2005;  S1756
  • 8 Howell D A, Bernadino K P, Ansari A, Lawrence C. Magnetic colonoscope imaging: can it reduce patient discomfort and shorten post-procedure recovery?.  DDW Abstract. 2005;  366
  • 9 Durai D, Williams J, Russell I. et al . What is the clinical effectiveness of endoscopy undertaken by nurses? Multi-institution nurse endoscopy trial (MINuET): ISRCTN 82 765 705.  DDW Abstract. 2005;  Sp 750
  • 10 Kiesslich R, Goetz M, Schneider C. et al . Confocal endomicroscopy as a novel method to diagnose colitis associated neoplasias in ulcerative colitis: a prospective randomized trial.  DDW Abstract. 2005;  483
  • 11 Inaba Y, Watari J, Okamoto K. et al . Usefulness of narrow band imaging system as a digital chromoendoscopy in screening colonoscopy: a prospective pilot study.  DDW Abstract. 2005;  T1346
  • 12 Hasuda K, Oda Y, Goto H. et al . The improvement of finding neoplastic lesions in colonoscopy with posture conversion.  DDW Abstract. 2005;  W1106
  • 13 Gizzi G, Pezzilli R, Villani V, Corinaldesi R. Impact of a prototype wide-angle colonoscope on polyp miss rates: a randomised endoscopic evaluation.  DDW Abstract. 2005;  T1341
  • 14 Bressler B, Paszat L, Rothwell D. et al . Predictors of missed colorectal cancer during colonoscopy: a population-based analysis.  DDW Abstract. 2005;  Sp751
  • 15 Barclay R L, Vicari J J, Johanson J F, Greenlaw J L. Variation in adenoma detection rates and colonoscopic withdrawal times during screening colonoscopy.  DDW Abstract. 2005;  Sp 752
  • 16 Altenhofen L, Knoepnadel J, Schmiegel W. et al . Acceptance and findings of the first nationwide screening colonoscopy round in Germany.  DDW Abstract. 2005;  637
  • 17 Birkner B R, Knöpnadel J, Altenhofen L. et al . Quality performance of screening colonoscopy in Germany.  DDW Abstract. 2005;  W1088
  • 18 Burke C A, Issa M, Church J. A nationwide survey of post-polypectomy surveillance colonoscopy: too many too soon!.  DDW Abstract. 2005;  W966
  • 19 Tanaka S, Oka S, Kaneko I. et al . Endoscopic submucosal dissection (ESD) method for colorectal laterally spreading tumor larger than 20 mm in diameter.  DDW Abstract. 2005;  T1398
  • 20 Inarrairaegui M, Borda F, Jimenez J. et al . Analysis of possible facilitating factors of perforation due to colonoscopy.  DDW Abstract. 2005;  S1097
  • 21 Pham B V, Brining D, Raju G S. et al . Endoscopic full thickness repair of colonic perforation in the porcine model using the Eagle Claw: a pilot study.  DDW Abstract. 2005;  T1375

B. P. Saunders, M.D., F.R.C.P.

Wolfson Unit for Endoscopy

St. Mark’s Hospital · Harrow, Middlesex · London HA1 3UJ · United Kingdom

Fax: +44-208-423 3588

Email: b.saunders@imperial.ac.uk