Literatur
-
1
Kolb C, Wille B, Maurer D. et al .
Avoidance of inappropriate mode switch due to far-field R-wave sensing in dual chamber pacemakers - final results of the FFS-test-study.
Eur Heart J.
2005;
P1177 (Suppl.)
-
2
Cools F JC, VanTwembeke R RC, Backers J, Verpooten G A.
Stability of far field R wave signals in different conditions.
Europace.
2003;
5
175-183
-
3
Kolb C, Aratma S, Zrenner B, Schmitt C.
Preventricular far-field sensing in the atrial channel of dual chamber pacemakers - an occasional cause of inappropriate mode switch.
J Interv Card Electrophysiol.
2004;
10
231-235
-
4
Willems R, Holemans P, Ector H, Van De Werf F, Heidbüchel H.
Paradoxical undersensing at a high sensitivity in dual chamber pacemakers.
Pacing Clin Electrophysiol.
2001;
24
308-315
-
5
Kolb C, Halbfaß P, Zrenner B, Schmitt C.
Paradoxical atrial undersensing due to inappropriate atrial noise reversion of atrial fibrillation in dual chamber pacemakers.
J Cardiovasc Electrophysiol.
2005;
16
696-700
-
6
Kolb C, Zrenner B, Schreieck J, Schmitt C.
Strategies to avoid inappropriate therapies due to ventricular double detection in biventricular pacing implantable cardioverter defibrillators.
Eur J Heart Fail.
2003;
5
523-526
-
7
Kolb C, Markwardt C, Zrenner B, Schmitt C.
Pacemaker auto-interference by thoracic impedance measurement for the rate response function.
Pacing Clin Electrophysiol.
2005;
28
1360-1362
-
8
Kolb C, Zrenner B, Schmitt C.
Incidence of electromagnetic interference in implantable cardioverter defibrillators.
Pacing Clin Electrophysiol.
2001;
24
465-468
-
9
Kolb C, Deisenhofer I, Weyerbrock S. et al .
Incidence of antitachycardia therapy suspension due to magnet reversion in implantable cardioverter defibrillators.
Pacing Clin Electrophysiol.
2004;
27
221-223
-
10
Naegeli B, Osswald S, Deola M, Burkart F.
Intermittent pacemaker dysfunction caused by digital mobile telephones.
J Am Coll Cardiol.
1996;
27
1471-1477
-
11
Hayes D L, Wang P J, Reynolds D W. et al .
Interference with cardiac pacemakers by cellular telephones.
N Engl J Med.
1997;
336
1473-1479
-
12
Altamura G, Toscano S, Gentilucci G. et al .
Influence of digital and analogue cellular telephones on implanted pacemakers.
Eur Heart J.
1997;
18
1632-1641
-
13
Kolb C, Schmieder S, Lehmann G. et al .
Do airport metal detectors interfere with implantable pacemakers or cardioverter defibrillators?.
J Am Coll Cardiol.
2003;
41
2054-2059
-
14
Dawson T W, Caputa K, Stuchly M A. et al .
Pacemaker interference by magnetic fields at power line frequencies.
IEEE Trans Biomed Eng.
2002;
49
254-262
-
15
Scholten A, Sily J.
The interference threshold of unipolar cardiac pacemakers in extremely low frequency magnetic fields.
J Med Eng Technol.
2001;
25
185-194
-
16
Crevenna R, Stix G, Pleiner J. et al .
Electromagnetic interference by transcutaneous neuromuscular electrical stimulation in patients with bipolar sensing implantable cardioverter defibrillators: a pilot safety study.
Pacing Clin Electrophysiol.
2003;
26
626-629
Dr. med. Christof Kolb
Deutsches Herzzentrum München
Lazarettstr. 36 · 80636 München
Telefon: 089 1218-2020
Fax: 089 1218-4593
eMail: kolb@dhm.mhn.de