Subscribe to RSS
DOI: 10.1055/s-2007-965652
© Georg Thieme Verlag KG Stuttgart · New York
Prospective Long-Term Follow-Up of the Cementless Bicontact Hip Stem with Plasmapore Coating
Publication History
Publication Date:
16 October 2007 (online)
Abstract
Aim: A prospective long-term study of the first 250 cementless Bicontact stems implanted in the BG Trauma Centre, Tuebingen, Germany. Method: All of the patients in this series (treatment period June 1987 to April 1990) who were still contactable were invited for clinical and radiological follow-up. The radiographs were analysed for signs of loosening in the form of Gruen lysis zones, stress shielding, subsidence behaviour, heterotopic ossification and spot welds. Results: The average follow-up period was 17.8 (16.7 - 19.5) years. The overall rate of follow-up was 65 % (162 of 250) and 91 % of patients who were still alive (162 of 179). The average patient age was 56.2 years at the time of operation and 74.0 years at follow-up. The average HHS was 81.6 points. In the course of the first 10 years (up to 03/1998), a total of 8 stem revisions had to be performed. In the period from 03/1998 to 01/2007, 2 cases of loosening requiring revision occurred in the patients still alive at the time of follow-up. The survival rate calculated was thus 95.6 %. Conclusion: These outstanding results provide enduring support for the philosophy of the cementless and bone-preserving fixation principles underlying the Bicontact hip stem with proximal intertrochanteric transmission of forces and high primary rotational stability.
Key words
total hip arthroplasty - cementless - proximal fixation - long‐term results
References
- 1 Acklin Y P, Berli B J, Frick W, Elke R, Morscher E W. Nine-year results of Muller cemented titanium straight stems in total hip replacement. Arch Orthop Trauma Surg. 2001; 121 391-398
- 2 Aldinger P R, Thomsen M, Mau H, Ewerbeck V, Breusch S J. Cementless spotorno titanium stems: excellent 10 - 15-year survival in 141 young patients. Acta Orth Scand. 2003; 74 253-258
- 3 Aldinger P R, Breusch S J, Lukoschek M, Mau H, Ewerbeck V, Thomsen M. A ten- to 15-year follow-up of the cementless spotorno stem. J Bone Joint Surg [Br]. 2003; 85 209-214
- 4 Archibeck M J, Berger R A, Quigley L R, Gitelis S, Rosenberg A G, Galante J. Second-generation cementless total hip arthroplasty. Eight to eleven year results. J Bone Joint Surg. 2001 [Am]; 83 1666-1673
- 5 Biedermann R, Krismer M, Stöckl B, Mayrhofer P, Ornstein E, Franzen H. Accuracy of EBRA‐FCA in the measurement of migration of femoral components of total hip replacement. Einzel-Bild-Röntgen-Analyse - femoral component analysis. J Bone Joint Surg [Br]. 1999; 81 266-272
- 6 Bobyn J D, Pilliar R M, Cameron H U, Weatherly G C. The optimum pore size for the fixation of porous-surfaced metal implants by the ingrowth of bone. Clin Orthop. 1980; 150 263-270
- 7 Brooker A F, Bowerman J W, Robinson R A, Riley L H. Ectopic ossifications following total hip replacement, incidence and a method of classification. J Bone Joint Surg [Am]. 1973; 55 1629-1632
- 8 Callaghan J J, Albright J C, Goetz D D, Olejniczak J P, Johnston R C. Charnley total hip arthroplasty with cement. Minimum twenty-five-year follow-up. J Bone Joint Surg [Am]. 2000; 82 487-497
- 9 Chlohishi J C, Harris W H. The Harris-Galante uncemented femoral component in primary total hip replacement at 10 years. J Arthroplasty. 1999; 14 915-917
- 10 D'Antonio J A, Capello W N, Manley M T, Geesink R G. Hydroxyapatite femoral stems for total hip arthroplasty. Clin Orthop. 2001; 393 101-111
- 11 Dobbs H S. Survivorship of total hip replacement. J Bone Joint Surg [Br]. 1980; 62 168-173
- 12 Duffy G P, Berry D J, Rowland C, Cabanela M E. Primary uncemented total hip arthroplasty in patients < 40 years old: 10- to 14-year results using first-generation proximally porous-coated implants. J Arthroplasty. 2001; 16 140-144
- 13 Eingartner C, Volkmann R, Heigele D, Weise K. Long-term results of an uncemented straight femoral shaft prosthesis. Hip Int. 2006; 16 23-32
- 14 Eingartner C, Ilchmann T, Dieter J, Weise K. Subsidence pattern of a cementless straight titanium femoral stem - a radiographic study with EBRA‐FCA. Hip International. 2005; 15 85-91
-
15 Eingartner C, Volkmann R, Ilchmann T, Weise K, Weller S.
A modular system for cemented and uncemented implantation of femoral stem prostheses. Szabo, Lewis, Fantini, Savalgi Surgical Technology International. San Francisco; Universal Medical Press 1998: 353-360 - 16 Eingartner C, Volkmann R, Winter E, Maurer F, Sauer G, Weller S, Weise K. Results of an uncemented straight femoral shaft prosthesis after 9 years of follow-up. J Arthroplasty. 2000; 15 440-447
- 17 Engh C A, Bobyn J D, Glassman A H. Porous-coated hip replacement: the factors governing bone ingrowth, stress shielding and clinical results. J Bone Joint Surg [Br]. 1987; 69 45-55
- 18 Engh C A, Claus A M, Hopper R H, Engh C A. Long-term results using the anatomic medullary locking hip prosthesis. Clin Orthop. 2001; 393 137-146
- 19 Engh C A, Massin P, Suthers K E. Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components. Clin Orthop. 1990; 257 107-128
- 20 Engh Jr C A, Culepper W J, Engh C A. Long-term results of use of the anatomic medullary locking prosthesis in total hip replacement. J Bone Joint Surg [Am]. 1997; 79 177-184
- 21 Evans B G, Salvati E A, Huo M H, Huk O L. The rationale for cemented total hip arthroplasty. Orthop Clin North Am. 1993; 24 599-610
- 22 Gruen T A, McNeice G M, Amstutz H C. “Modes of failure” of cemented stem-type femoral components. Clin Orthop. 1979; 141 17-27
- 23 Harris W. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by arthroplasty. An end-result study using a new method of result-evaluation. J Bone Joint Surg [Am]. 1969; 51 737-755
- 24 Hellmann E J, Capello W N, Feinberg J R. Omnifit cementless total hip arthroplasty - a 10-year average follow-up. Clin Orthop. 1999; 364 164-174
- 25 Huggler A H, Jacob H A, Bereiter H, Haverkorn M, Ryf C, Schenk R. Long-term results with the uncemented thrust plate prosthesis (TPP). Acta Orthop Belg. 1993; 59 (Suppl 1) 215-223
- 26 Johnston R C, Fitzgerald R H, Harris W H, Poss R, Müller M E, Sledge C B. Clinical and radiographic evaluation of total hip replacement. J Bone Joint Surg [Am]. 1990; 72 161-168
- 27 Jones L C, Hungerford D S. Cement disease. Clin Orthop. 1987; 225 192-206
- 28 Kawamura M, Dunbar M J, Murray P, Bourne R B, Rorabeck C H. The porous coated anatomic total hip replacement. A ten to fourteen-year follow-up study of a cementless total hip arthroplasty. J Bone Joint Surg [Am]. 2001; 83 1333-1338
- 29 Keisu K S, Mathiesen E B, Lindgren J U. The uncemented fully textured Lord hip prosthesis: a 10- to 15-year follow-up study. Clin Orthop. 2001; 382 133-142
- 30 Kim Y H, Kim J S, Cho S H. Primary total hip arthroplasty with a cementless porous-coated anatomic total hip prosthesis: 10- to 12-year results of prospective and consecutive series. J Arthroplasty. 1999; 14 538-548
- 31 Knahr K, Kryspin-Exner I, Jagsch R, Freilinger W, Kasparek M. [Evaluating the quality of life before and after implantation of a total hip endoprosthesis] Beurteilung der Lebensqualität vor und nach Implantation einer Hüfttotalendoprothese. Z Orthop Ihre Grenzgeb. 1998; 136 321-329
- 32 McLaughlin J R, Lee K R. Total hip arthroplasty with an uncemented femoral component - excellent results at ten-year follow-up. J Bone Joint Surg [Br]. 1997; 79 900-907
- 33 McLaughlin J R, Lee K R. Total hip arthroplasty in young patients. 8- to 13-year results using an uncemented stem. Clin Orthop. 2000; 373 153-163
- 34 Murray D W, Britton A R, Bulstrode C J. Loss to follow-up matters. J Bone Joint Surg [Br]. 1997; 79 254-257
- 35 Murray D W, Carr A J, Bulstrode C J. Survival analysis of joint replacements. J Bone Joint Surg [Br]. 1993; 75 697-704
- 36 Oishi C S, Walker R H, Colwell C WJ. The femoral component in total hip arthroplasty. Six to eight year follow-up of one hundred consecutive patients after use of a third-generation cementing technique. J Bone Joint Surg [Am]. 1994; 76 1130-1136
- 37 Rothman K J. Estimation of confidence limits for the cumulative probability of survival in life table analysis. J Chron Dis. 1978; 31 557-560
- 38 Sakalkale D P, Eng K, Hozak W J, Rothman R H. Minimum 10-year results of a tapered cementless hip replacement. Clin Orthop. 1999; 362 138-144
- 39 Schramm M, Keck F, Hohmann D, Pitto R P. Total hip arthroplasty using an uncemented femoral component with taper design: outcome at 10-year follow-up. Arch Orthop Trauma Surg. 2000; 120 407-412
- 40 Siebold R, Scheller G, Schreiner U, Jani L. [Long-term results with the cement-free Spotorno CLS shaft] Langzeitergebnisse mit dem zementfreien CLS-Schaft von Spotorno. Orthopäde. 2001; 30 317-322
- 41 Simanek H G, Brocai D RC, Reiser D, Thomsen M, Sabo D, Lukoschek M. Middle term results of threaded acetabular cups. J Bone Joint Surg [Br]. 1997; 79 366-370
- 42 Volkmann R, Eingartner C, Winter E, Weise K, Weller S. Mid term results in 500 titanium alloy straight femoral shaft prostheses - cemented and cementless technique. Eur J Orthop Surg Traumatol. 1998; 8 133-139
- 43 Xenos J S, Callaghan J J, Heekin R D, Hopkinson W J, Savory C G, Moore M S. The porous-coated anatomic total hip prosthesis, inserted without cement - a prospective study with a minimum of ten years of follow-up. J Bone Joint Surg [Am]. 1999; 81 74-82
- 44 Yahiro M A, Gantenberg J B, Nelson R, Lu H TC, Mishra N K. Comparison of the results of cemented, porous-ingrowth, and threaded acetabular cup fixation. J Arthroplasty. 1995; 10 339-350
- 45 Zenz P, Pospisil C, Fertschak W, Schwägerl W. [10 years of cementless implantation of total hip endoprosthesis using Zweymuller's stem] 10 Jahre zementfreie Implantation von Hüfttotalendoprothesen unter Verwendung des Zweymüller-Schaftes. Z Orthop. 1995; 133 558-561
Dr. MD Uwe Ochs
Berufsgenossenschaftliche Unfallklinik
Schnarrenbergstr. 95
72076 Tuebingen
Germany
Phone: + 49 70 71 6 06 11 67
Fax: + 49 70 71 6 06 10 02
Email: uochs@bgu-tuebingen.de