Ultrasound Cerebral Perfusion Analysis Based on a Mathematical Model for Diminution Harmonic Imaging

C. Kier
1   Institute for Signal Processing, University of Lübeck, Lübeck, Germany
,
K. Meyer-Wiethe
2   Department of Neurology, University Hospital Schleswig-Holstein, Lübeck, Germany
,
G. Seidel
2   Department of Neurology, University Hospital Schleswig-Holstein, Lübeck, Germany
,
T. Aach
3   Institute of Imaging and Computer Vision, RWTH Aachen University, Aachen, Germany
› Author Affiliations
Further Information

Publication History

Publication Date:
20 January 2018 (online)

Summary

Objectives: Cerebral vascular diseases are detectable by CT/MRI-based methods. Drawbacks of these methods are that they are expensive, time-consuming and intolerable to critically ill patients. Ultrasound, as an inexpensive bedside method, promises to become an alternative. Among other harmonic imaging methods, the diminution harmonic imaging (DHI) method is known, which determines perfusion-related parameters by analyzing ultrasound contrast agent (UCA) diminution kinetics based on constant UCA infusion. The shortcoming of DHI is that the used mathematical model can only determine these parameters by least squares fitting the model onto the data.

Methods: In this work, the underlying mathematical model is further developed such that it becomes possible to directly calculate the parameters from the image data. Furthermore, the new model offers an improved way to estimate the spatial distribution of the destruction coefficient necessary for accurately determining the destruction power of the ultrasound pulse on the contrast agent.

Results: The direct calculation of the perfusion coefficient is much faster thanthe former fitting of the model. Perfusion as well as destruction coefficients are displayed as color-coded images. In an example, a region with perfusion deficits (as shown in a MR image of the same patient) is clearly identifiable.

Conclusions: Displaying the parameters as color-coded images facilitates result interpretation for the diagnosing physician. The results are preliminary and still have to be validated, but they suggest that the new DHI model improves the significance of ultrasound as a diagnostic help.

 
  • References

  • 1 Hacke W, Donnan G, Fieschi C, Kaste M, von Kummer R, Broderick JP. et al. Association of outcome with early stroke treatment: pooled analysis of ATLANTIS, ECASS, and NINDS rt-PA stroke trials. Lancet 2004; 363 9411 768-774.
  • 2 Thomalla G, Schwark C, Sobesky J, Bluhmki E, Fiebach JB, Fiehler J. et al. Outcome and Symptomatic Bleeding Complications of Intravenous Thrombolysis within 6 Hours in MRI-Selected Stroke Patients. Stroke 2006; 37 (03) 852-858.
  • 3 Porter T, Xie F. Transient myocardial contrast after exposure to diagnostic ultrasound pressure with minute doses of intravenously injected micro-bubbles: demonstration and potential mechanisms. Circulation 1995; 92 (09) 2391-2395.
  • 4 Seidel G, Greis C, Sonne J, Kaps M. Harmonic gray-scale imaging of the human brain. Journal of Neuroimaging 1999; 09: 171-174.
  • 5 Seidel G, Algermissen C, Christoph A, Claasen L, Vidal-Langwasser M, Katzer T. Harmonic imaging of the human brain: Visualization of brain perfusion withultrasound. Stroke 2000; 31 (01) 151-154.
  • 6 Kier C, Toth D, Meyer-Wiethe K, Schindler A, Cangür H, Seidel G. et al. Cerebral Perfusion Imaging with Bolus Harmonic Imaging. Walker WF, Emelianov SY. Ultrasonic Imaging and Signal Processing. vol. 5750 of Proceedings of SPIE.. San Diego, CA: 2005: 437-446.
  • 7 Seidel G, Meyer-Wiethe K, Berdien G, Hollstein D, Toth D, Aach T. Ultrasound Perfusion Imaging in Acute Middle Cerebral Artery Infarction Predicts Outcome. Stroke 2004; 35 (05) 1107-1111.
  • 8 Meyer K, Seidel G. Transcranial contrast diminution imaging of the human brain – a pilot study on healthy volunteers. Ultrasound in Medicine and Biology 2002; 28 11-12 1433-1437.
  • 9 Kern R, Perren F, Schöneberger K, Gass A, Hennerici M, Meairs S. Ultrasound Microbubble Destruction Imaging in Acute Middle Cerebral Artery Stroke. Stroke 2004; 35 (07) 1665-1670.
  • 10 Metzler V, Seidel G, Wiesmann M, Meyer K, Aach T. Perfusion Harmonic Imaging of the Human Brain. Ultrasonic Imaging and Signal Processing. vol. 5035 of Proceedings of SPIE.. San Diego, CA: 2003: 337-348.
  • 11 Wilkening W, Postert T, Federlein J, Kono Y, Mattrey R, Ermert H. Ultrasonic assessment of perfusion conditions in the brain and in the liver. IEEE Ultrasonics Symposium.. San Juan, Puerto Rico: 2000: 1545-1548.
  • 12 Eyding J, Wilkening W, Reckhardt M, Schmid G, Meves S, Ermert H. et al. Contrast burst depletion imaging (CODIM): anew imaging procedure and analysis method for semiquantitative ultrasonic perfusion imaging. Stroke 2003; 34 (01) 77-83.
  • 13 Eyding J, Wilkening W, Reckhardt M, Meves S, Postert T. Reliability of semiquantitative ultrasonic perfusion imaging of the brain. Journal of Neuroimaging 2004; 14 (02) 143-149.