Subscribe to RSS
DOI: 10.1055/a-0959-6138
The best approach for sampling of pancreatic neuroendocrine tumors – EUS-FNA or EUS-FNB?
Corresponding author
Publication History
Publication Date:
22 October 2019 (online)
The limitations of transabdominal ultrasound in diagnosis of pancreatic diseases [1] were the driving force in developing endosonography (EUS) with the first echoendoscope being launched in 1980 [2]. The curvilinear array design of modern echoendoscope transducer heads enables EUS-guided sampling of lesions [3]. Traditionally, the principal sampling technique has been EUS-guided fine-needle aspiration (EUS-FNA) with open-tip needles designed for cytology [4].
Among all neoplasms originating from the pancreas, pancreatic neuroendocrine tumors (PanNETs) constitute a relatively rare entity. Incidence of PanNETs reportedly is increasing [5], and these tumors are challenging to diagnose with imaging alone [6], which implicates sampling of lesions suspected for PanNET. In addition, immunostaining for entity-specific tumor markers is required for reliable microscopic diagnosis [7].
Problematically, EUS-FNA is suboptimal in solid pancreatic lesions, with an 85 % sensitivity for malignancy [8]. Furthermore, a majority of publications include mostly or exclusively pancreatic ductal adenocarcinomas [9] [10]. The few studies addressing PanNETs have shown varying diagnostic sensitivity for EUS-FNA, ranging from 47 % [11] to 90 % [12], ([Fig. 1]).
In recent years, a new generation of biopsy needles (EUS-FNB [fine-needle biopsy]) has been developed for acquisition of whole tissue samples [13] [14] [15]. At present, it is not known whether FNB needles and processing of histology specimens can improve diagnosis of suspected PanNETs and motivate a shift from EUS-FNA.
In this issue of Endoscopy International Open, Eusebi et al contribute new knowledge on this important topic by investigating the diagnostic yield and sensitivity of EUS-FNB. The study has a retrospective design and it was conducted in a two-center setting during a 13-year period (2004−2017). Exclusively PanNETs were included and 102 EUS-guided sampling procedures were analyzed in 91 patients. Sampling was performed either by EUS-FNA (22/25-gauge needle), by EUS-FNB, or by both modalities. From 2004 to 2011, a 19-gauge Quick-Core FNB-needle (Cook Medical, Limerick, Ireland) was used while using a 22/25-gauge reverse bevel ProCore FNB-needle (Cook Medical) or a 22-gauge opposing bevel SharkCore FNB-needle (Medtronic, Minneapolis, Minnesota, United States) from 2011 to 2017.
The authors report that the diagnostic yield, i. e. the acquisition of a macroscopically adequate sample, was 85 % (35/41) in EUS-FNB and 78 % (69/89) in EUS-FNA. In an intention-to-diagnose analysis, the final diagnostic sensitivity of EUS-FNB and EUS-FNA was 80 % (33/41) and 69 % (61/89), respectively. In dual sampling procedures (n = 28), the combination of EUS-FNB and EUS-FNA had a significantly higher diagnostic yield than EUS-FNA alone, 96 % (27/28) vs 75 % (21/28), P = 0.023. Either of the two techniques was diagnostic for PanNET in all of the 27 adequate samples. Seven EUS-FNA samples were inadequate for a conclusive diagnosis and in six of seven of these cases (86 %), the EUS-FNB sample was diagnostic. On the other hand, in six cases EUS-FNB was non-diagnostic and in all of these six cases, EUS-FNA was diagnostic. No noticeable difference in diagnostic performance was seen between the three FNB needles. No adverse events were recorded after EUS-FNB, which is a finding in line with the results of other studies [14] [16].
The study by Eusebi et al is important because a high number of patients were included and small PanNETs were not excluded. Moreover, few studies on EUS-FNB have been performed in cohorts containing exclusively PanNETs [17]. There are some weaknesses in the study discussed by the authors. As an example, different types of FNB needles were used, one of which – the Quick-Core needle – has been discarded by most endosonographers due to a high frequency of technical failures and a low diagnostic accuracy [18].
According to a recent study on solid pancreatic lesions [19], the accuracy of the reverse bevel FNB needle was found inferior (74 %) to that of the opposing bevel FNB needle (92 %). The number of cases sampled by EUS-FNB in the study by Eusebi and co-workers was not sufficient to determine which FNB needle is the superior one. Furthermore, there are yet other FNB needles available, such as the Franseen tip needle [20].
Importantly, the comparison of EUS-FNB and EUS-FNA is not exclusively a comparison between needles but rather a comparison between two different diagnostic approaches, which also include sampling maneuvers, sample preparation, and sample assessment by the (cyto)pathologist. Poor quality at any of these steps will result in a non-diagnostic work-up. This is a crucial aspect to keep in mind when interpreting studies investigating the accuracy of EUS-guided sampling.
Even though Eusebi and co-workers present valuable new data, it remains to be decided to what extent EUS-FNB may be superior to EUS-FNA in the work-up of suspected PanNETs. This study, like others [21], shows that EUS-FNB is a useful adjunct to EUS-FNA. Whether EUS-FNB should be used as the primary technique, or as a rescue technique after an unsuccessful EUS-FNA, warrants further investigation. Studies analyzing the benefit of combining a 25-gauge FNA needle and a 22-gauge reverse bevel FNB needle in the same solid pancreatic lesion have shown contradictory results [21] [22]. Moreover, such an approach implicates increased costs and a prolonged procedural time. Therefore, dual-modality sampling should be considered only in strictly selected cases. Future studies focusing on PanNETs should be designed as prospective, randomized trials using a predefined set of FNA and FNB needles with surgical specimens as the reference standard.
#
Competing interests
None
-
References
- 1 DiMagno EP, Malagelada JR, Taylor WF. et al. A prospective comparison of current diagnostic tests for pancreatic cancer. N Engl J Med 1977; 297: 737-742
- 2 DiMagno EP, Buxton JL, Regan PT. et al. Ultrasonic endoscope. Lancet 1980; 1: 629-631
- 3 Vilmann P, Khattar S, Hancke S. Endoscopic ultrasound examination of the upper gastrointestinal tract using a curved-array transducer. A preliminary report. Surg Endosc 1991; 5: 79-82
- 4 Vilmann P, Hancke S. A new biopsy handle instrument for endoscopic ultrasound-guided fine-needle aspiration biopsy. Gastrointest Endosc 1996; 43: 238-242
- 5 Yao JC, Hassan M, Phan A. et al. One hundred years after “carcinoid”: epidemiology of and prognostic factors for neuroendocrine tumors in 35,825 cases in the United States. J Clin Oncol 2008; 26: 3063-3072
- 6 Delbeke D, Pinson CW. Pancreatic tumors: role of imaging in the diagnosis, staging, and treatment. J Hepatobiliary Pancreat Surg 2004; 11: 4-10
- 7 Falconi M, Bartsch DK, Eriksson B. et al. ENETS Consensus Guidelines for the management of patients with digestive neuroendocrine neoplasms of the digestive system: well-differentiated pancreatic non-functioning tumors. Neuroendocrinology 2012; 95: 120-134
- 8 Hewitt MJ, McPhail MJ, Possamai L. et al. EUS-guided FNA for diagnosis of solid pancreatic neoplasms: a meta-analysis. Gastrointest Endosc 2012; 75: 319-331
- 9 Alatawi A, Beuvon F, Grabar S. et al. Comparison of 22G reverse-beveled versus standard needle for endoscopic ultrasound-guided sampling of solid pancreatic lesions. United Eur Gastroenterol J 2015; 3: 343-352
- 10 Hebert-Magee S, Bae S, Varadarajulu S. et al. The presence of a cytopathologist increases the diagnostic accuracy of endoscopic ultrasound-guided fine needle aspiration cytology for pancreatic adenocarcinoma: a meta-analysis. Cytopathology 2013; 24: 159-171
- 11 Voss M, Hammel P, Molas G. et al. Value of endoscopic ultrasound guided fine needle aspiration biopsy in the diagnosis of solid pancreatic masses. Gut 2000; 46: 244-249
- 12 Atiq M, Bhutani MS, Bektas M. et al. EUS-FNA for pancreatic neuroendocrine tumors: a tertiary cancer center experience. Dig Dis Sci 2012; 57: 791-800
- 13 Bang JY, Hebert-Magee S, Navaneethan U. et al. EUS-guided fine needle biopsy of pancreatic masses can yield true histology: results of a randomised trial. Gut 2018; 67: 2081-2084
- 14 Iglesias-Garcia J, Poley JW, Larghi A. et al. Feasibility and yield of a new EUS histology needle: results from a multicenter, pooled, cohort study. Gastrointest Endosc 2011; 73: 1189-1196
- 15 Jovani M, Abidi WM, Lee LS. Novel fork-tip needles versus standard needles for EUS-guided tissue acquisition from solid masses of the upper GI tract: a matched cohort study. Scand J Gastroenterol 2017; 52: 784-787
- 16 Bang JY, Hebert-Magee S, Trevino J. et al. Randomized trial comparing the 22-gauge aspiration and 22-gauge biopsy needles for EUS-guided sampling of solid pancreatic mass lesions. Gastrointest Endosc 2012; 76: 321-327
- 17 Witt BL, Factor RE, Chadwick BE. et al. Evaluation of the SharkCore((R)) needle for EUS-guided core biopsy of pancreatic neuroendocrine tumors. Endoscopic ultrasound 2018; 7: 323-328
- 18 Fernandez-Esparrach G, Sendino O, Sole M. et al. Endoscopic ultrasound-guided fine-needle aspiration and trucut biopsy in the diagnosis of gastric stromal tumors: a randomized crossover study. Endoscopy 2010; 42: 292-299
- 19 Nayar MK, Paranandi B, Dawwas MF. et al. Comparison of the diagnostic performance of 2 core biopsy needles for EUS-guided tissue acquisition from solid pancreatic lesions. Gastrointest Endosc 2017; 85: 1017-1024
- 20 Mitri RD, Rimbas M, Attili F. et al. Performance of a new needle for endoscopic ultrasound-guided fine-needle biopsy in patients with pancreatic solid lesions: A retrospective multicenter study. Endosc Ultrasound 2018; 7: 329-334
- 21 Hedenstrom P, Demir A, Khodakaram K. et al. EUS-guided reverse bevel fine-needle biopsy sampling and open tip fine-needle aspiration in solid pancreatic lesions - a prospective, comparative study. Scand J Gastroenterol 2018; 53: 231-237
- 22 Berzosa M, Villa N, El-Serag HB. et al. Comparison of endoscopic ultrasound guided 22-gauge core needle with standard 25-gauge fine-needle aspiration for diagnosing solid pancreatic lesions. Endosc Ultrasound 2015; 4: 28-33
Corresponding author
-
References
- 1 DiMagno EP, Malagelada JR, Taylor WF. et al. A prospective comparison of current diagnostic tests for pancreatic cancer. N Engl J Med 1977; 297: 737-742
- 2 DiMagno EP, Buxton JL, Regan PT. et al. Ultrasonic endoscope. Lancet 1980; 1: 629-631
- 3 Vilmann P, Khattar S, Hancke S. Endoscopic ultrasound examination of the upper gastrointestinal tract using a curved-array transducer. A preliminary report. Surg Endosc 1991; 5: 79-82
- 4 Vilmann P, Hancke S. A new biopsy handle instrument for endoscopic ultrasound-guided fine-needle aspiration biopsy. Gastrointest Endosc 1996; 43: 238-242
- 5 Yao JC, Hassan M, Phan A. et al. One hundred years after “carcinoid”: epidemiology of and prognostic factors for neuroendocrine tumors in 35,825 cases in the United States. J Clin Oncol 2008; 26: 3063-3072
- 6 Delbeke D, Pinson CW. Pancreatic tumors: role of imaging in the diagnosis, staging, and treatment. J Hepatobiliary Pancreat Surg 2004; 11: 4-10
- 7 Falconi M, Bartsch DK, Eriksson B. et al. ENETS Consensus Guidelines for the management of patients with digestive neuroendocrine neoplasms of the digestive system: well-differentiated pancreatic non-functioning tumors. Neuroendocrinology 2012; 95: 120-134
- 8 Hewitt MJ, McPhail MJ, Possamai L. et al. EUS-guided FNA for diagnosis of solid pancreatic neoplasms: a meta-analysis. Gastrointest Endosc 2012; 75: 319-331
- 9 Alatawi A, Beuvon F, Grabar S. et al. Comparison of 22G reverse-beveled versus standard needle for endoscopic ultrasound-guided sampling of solid pancreatic lesions. United Eur Gastroenterol J 2015; 3: 343-352
- 10 Hebert-Magee S, Bae S, Varadarajulu S. et al. The presence of a cytopathologist increases the diagnostic accuracy of endoscopic ultrasound-guided fine needle aspiration cytology for pancreatic adenocarcinoma: a meta-analysis. Cytopathology 2013; 24: 159-171
- 11 Voss M, Hammel P, Molas G. et al. Value of endoscopic ultrasound guided fine needle aspiration biopsy in the diagnosis of solid pancreatic masses. Gut 2000; 46: 244-249
- 12 Atiq M, Bhutani MS, Bektas M. et al. EUS-FNA for pancreatic neuroendocrine tumors: a tertiary cancer center experience. Dig Dis Sci 2012; 57: 791-800
- 13 Bang JY, Hebert-Magee S, Navaneethan U. et al. EUS-guided fine needle biopsy of pancreatic masses can yield true histology: results of a randomised trial. Gut 2018; 67: 2081-2084
- 14 Iglesias-Garcia J, Poley JW, Larghi A. et al. Feasibility and yield of a new EUS histology needle: results from a multicenter, pooled, cohort study. Gastrointest Endosc 2011; 73: 1189-1196
- 15 Jovani M, Abidi WM, Lee LS. Novel fork-tip needles versus standard needles for EUS-guided tissue acquisition from solid masses of the upper GI tract: a matched cohort study. Scand J Gastroenterol 2017; 52: 784-787
- 16 Bang JY, Hebert-Magee S, Trevino J. et al. Randomized trial comparing the 22-gauge aspiration and 22-gauge biopsy needles for EUS-guided sampling of solid pancreatic mass lesions. Gastrointest Endosc 2012; 76: 321-327
- 17 Witt BL, Factor RE, Chadwick BE. et al. Evaluation of the SharkCore((R)) needle for EUS-guided core biopsy of pancreatic neuroendocrine tumors. Endoscopic ultrasound 2018; 7: 323-328
- 18 Fernandez-Esparrach G, Sendino O, Sole M. et al. Endoscopic ultrasound-guided fine-needle aspiration and trucut biopsy in the diagnosis of gastric stromal tumors: a randomized crossover study. Endoscopy 2010; 42: 292-299
- 19 Nayar MK, Paranandi B, Dawwas MF. et al. Comparison of the diagnostic performance of 2 core biopsy needles for EUS-guided tissue acquisition from solid pancreatic lesions. Gastrointest Endosc 2017; 85: 1017-1024
- 20 Mitri RD, Rimbas M, Attili F. et al. Performance of a new needle for endoscopic ultrasound-guided fine-needle biopsy in patients with pancreatic solid lesions: A retrospective multicenter study. Endosc Ultrasound 2018; 7: 329-334
- 21 Hedenstrom P, Demir A, Khodakaram K. et al. EUS-guided reverse bevel fine-needle biopsy sampling and open tip fine-needle aspiration in solid pancreatic lesions - a prospective, comparative study. Scand J Gastroenterol 2018; 53: 231-237
- 22 Berzosa M, Villa N, El-Serag HB. et al. Comparison of endoscopic ultrasound guided 22-gauge core needle with standard 25-gauge fine-needle aspiration for diagnosing solid pancreatic lesions. Endosc Ultrasound 2015; 4: 28-33