Endobiliary radiofrequency ablation for ingrowth occlusion after bilateral metal stent placement in patients with malignant hilar biliary obstruction

Tadahisa Inoue
Department of Gastroenterology, Aichi Medical University, Aichi, Japan
,
Rena Kitano
Department of Gastroenterology, Aichi Medical University, Aichi, Japan
,
Masashi Yoneda
Department of Gastroenterology, Aichi Medical University, Aichi, Japan
› Institutsangaben
 

Endobiliary radiofrequency ablation (RFA) can prolong the patency of bilateral metal stents (MS) in patients with malignant hilar biliary obstruction [1]. In addition, RFA is a potential treatment option for stent occlusion caused by ingrowth after MS placement [2]. However, there is no evidence of the feasibility of RFA in treating ingrowth after bilateral placement and the safety of repeated RFA remains unknown. Here, we describe a patient who underwent RFA reintervention for ingrowth occlusion after bilateral stent-by-stent (SBS) MS placement with RFA.

An 84-year-old woman with unresectable cholangiocarcinoma had undergone bilateral SBS placement using an uncovered MS (ZeoStent V, Zeon Medical, Tokyo, Japan), following RFA to the left and right hepatic duct strictures using Habib EndoHPB Catheter (Boston Scientific, Marlborough, Massachusetts, United States) and VIO300 D generator (ERBE Elektromedizin GmbH, Tubingen, Germany). Six months after the procedure, obstructive jaundice recurred due to stent occlusion; thus, we performed endoscopic reintervention. After biliary cannulation, two guidewires were advanced into the left and right intrahepatic bile ducts through each MS. A cholangioscope (SpyGlass DS; Boston Scientific) was subsequently inserted over the guidewire, and the cause of occlusion was determined to be an ingrowth in the hilar region. We then performed RFA to the ingrowth within each MS for 90 s at 7 W. Tissue debris was retrieved using a balloon catheter, and the stent lumen was successfully recanalized ( [Fig.1] and [Video 1]). The patient’s symptoms improved without adverse events, and the stents were patent during the follow-up period.

Zoom Image
Fig. 1a Cholangiography revealed strictures within previously placed metal stents in the hilar region due to ingrowth. b Radiofrequency ablation was performed of the ingrowth region within the right metal stent. c Radiofrequency ablation was performed of the ingrowth region within the left metal stent. d After the ablation, tissue debris was retrieved with a balloon catheter, and the stricture improved.

Video 1 Endobiliary radiofrequency ablation for ingrowth occlusion after bilateral stent-by-stent placement in a patient with malignant hilar biliary obstruction.


Qualität:

Conclusions

The management of stent occlusion after bilateral MS placement has not been established. Endobiliary RFA may be a useful option when treating ingrowth occlusion, especially after SBS placement.


#
#

Competing interests

Dr. Inoue received honoraria from Boston Scientific Japan and Japan Lifeline Co., Ltd, outside the submitted work.
The other authors disclose no financial relationships relevant to this publication.


Corresponding author

Tadahisa Inoue, MD, PhD
Department of Gastroenterology
Aichi Medical University
Yazakokarimata, Nagakute
Aichi 480-1195
Japan   
Fax: +81 561 63 3208   

Publikationsverlauf

Artikel online veröffentlicht:
27. Mai 2021

© 2021. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/)

Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany


Zoom Image
Fig. 1a Cholangiography revealed strictures within previously placed metal stents in the hilar region due to ingrowth. b Radiofrequency ablation was performed of the ingrowth region within the right metal stent. c Radiofrequency ablation was performed of the ingrowth region within the left metal stent. d After the ablation, tissue debris was retrieved with a balloon catheter, and the stricture improved.