CC BY-NC-ND 4.0 · Endosc Int Open 2021; 09(11): E1801-E1810
DOI: 10.1055/a-1526-1208
Original article

Common bile duct size in malignant distal obstruction and lumen-apposing metal stents: a multicenter prospective study

Mihai Rimbaş
 1   Digestive Endoscopy Unit, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
 3   Department of Internal Medicine, Carol Davila University of Medicine, Bucharest, Romania
,
Andrea Anderloni
 4   Digestive Endoscopy Unit, Division of Gastroenterology, Humanitas Clinical and Research Center, IRCCS, Rozzano, Milan, Italy
,
Bertrand Napoléon
 5   Endoscopy Unit, Jean Mermoz Private Hospital, Ramsay Generale de Santé, Lyon, France
,
Andrada Seicean
 6   Department of Gastroenterology, Regional Institute of Gastroenterology and Hepatology, Iuliu Haţieganu University of Medicine, Cluj-Napoca, Romania
,
Edoardo Forti
 7   Digestive Endoscopy Unit, Grande Ospedale Metropolitano Niguarda, Milan, Italy
,
Stefano Francesco Crinò
 8   Gastroenterology and Digestive Endoscopy Unit, The Pancreas Institute, G.B. Rossi University Hospital, Verona, Italy
,
Ilaria Tarantino
 9   Endoscopy Service, Department of Diagnostic and Therapeutic Services, Istituto Mediterraneo per i Trapianti e Terapie ad alta Specializzazione, Palermo, Italy
,
Paolo Giorgio Arcidiacono
10   Pancreato-Biliary Endoscopy and Endosonography Division, Pancreas Translational & Clinical Research Center, Vita-Salute San Raffaele University, IRCCS San Raffaele Scientific Institute, Milan, Italy
,
Carlo Fabbri
11   Gastroenterology and Digestive Endoscopy Unit, Forlì-Cesena Hospitals, AUSL Romagna, Italy
,
Gianenrico Rizzatti
 1   Digestive Endoscopy Unit, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
12   CERTT, Center for Endoscopic Research Therapeutics and Training, Catholic University, Rome, Italy
,
Arnaldo Amato
13   Gastroenterology Division, Valduce Hospital, Como, Italy
,
Theodor Voiosu
 2   Gastroenterology Department, Colentina Clinical Hospital, Bucharest, Romania
 3   Department of Internal Medicine, Carol Davila University of Medicine, Bucharest, Romania
,
Alessandro Fugazza
 4   Digestive Endoscopy Unit, Division of Gastroenterology, Humanitas Clinical and Research Center, IRCCS, Rozzano, Milan, Italy
,
Ofelia Moșteanu
 6   Department of Gastroenterology, Regional Institute of Gastroenterology and Hepatology, Iuliu Haţieganu University of Medicine, Cluj-Napoca, Romania
,
Àngels Ginès
14   Endoscopy Unit, Institut de Malalties Digestives i Metabòliques, Hospital Clínic, University of Barcelona, IDIBAPS, CIBEREHD, Barcelona, Spain
,
Germana de Nucci
15   Gastroenterology Unit, ASST Rhodense, Garbagnate Milanese, Italy
,
Pietro Fusaroli
16   Gastroenterology Unit, Hospital of Imola, Department of Medical and Surgical Sciences, University of Bologna, Italy
,
Nam Quoc Nguyen
17   Department of Gastroenterology, Royal Adelaide Hospital, Adelaide, Australia
,
Roberto Di Mitri
18   Gastroenterology and Endoscopy Unit, ARNAS Civico – Di Cristina – Benfratelli, Palermo, Italy
,
Leonardo Minelli Grazioli
19   Digestive Endoscopy Unit and Gastroenterology, Fondazione Poliambulanza, Brescia, Italia
,
Massimiliano Mutignani
 7   Digestive Endoscopy Unit, Grande Ospedale Metropolitano Niguarda, Milan, Italy
,
Livia Archibugi
10   Pancreato-Biliary Endoscopy and Endosonography Division, Pancreas Translational & Clinical Research Center, Vita-Salute San Raffaele University, IRCCS San Raffaele Scientific Institute, Milan, Italy
,
Cecilia Binda
11   Gastroenterology and Digestive Endoscopy Unit, Forlì-Cesena Hospitals, AUSL Romagna, Italy
,
Anna Cominardi
16   Gastroenterology Unit, Hospital of Imola, Department of Medical and Surgical Sciences, University of Bologna, Italy
,
Carmelo Barbera
20   U.O.C. di Gastroenterologia ed Endoscopia Digestiva, Ospedale Giuseppe Mazzini, ASL Teramo, Italy
,
Glòria Fernández-Esparrach
14   Endoscopy Unit, Institut de Malalties Digestives i Metabòliques, Hospital Clínic, University of Barcelona, IDIBAPS, CIBEREHD, Barcelona, Spain
,
Laurent Palazzo
21   Department of Endoscopy, Trocadero Clinic, Paris, France
,
Maxime Palazzo
22   Digestive Endoscopy Unit, Beaujon University Hospital, Clichy-la-Garenne, France
,
Jan Werner Poley
23   Department of Gastroenterology and Hepatology, Erasmus MC, University Medical Center, Rotterdam, the Netherlands
,
Cristiano Spada
 1   Digestive Endoscopy Unit, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
19   Digestive Endoscopy Unit and Gastroenterology, Fondazione Poliambulanza, Brescia, Italia
,
Giorgio Valerii
20   U.O.C. di Gastroenterologia ed Endoscopia Digestiva, Ospedale Giuseppe Mazzini, ASL Teramo, Italy
,
Takao Itoi
24   Department of Gastroenterology and Hepatology, Tokyo Medical University Hospital, Tokyo, Japan
,
Yukitoshi Matsunami
24   Department of Gastroenterology and Hepatology, Tokyo Medical University Hospital, Tokyo, Japan
,
Radu Bogdan Mateescu
 2   Gastroenterology Department, Colentina Clinical Hospital, Bucharest, Romania
 3   Department of Internal Medicine, Carol Davila University of Medicine, Bucharest, Romania
,
Cristian Băicuș
 3   Department of Internal Medicine, Carol Davila University of Medicine, Bucharest, Romania
,
Guido Costamagna
 1   Digestive Endoscopy Unit, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
12   CERTT, Center for Endoscopic Research Therapeutics and Training, Catholic University, Rome, Italy
,
Alberto Larghi
 1   Digestive Endoscopy Unit, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
12   CERTT, Center for Endoscopic Research Therapeutics and Training, Catholic University, Rome, Italy
› Author Affiliations
 

Abstract

Background and study aims Feasibility of EUS-guided choledochoduodenostomy (EUS-CDS) using available lumen-apposing stents (LAMS) is limited by the size of the common bile duct (CBD) (≤ 12 mm, cut-off for experts; 15 mm, cut-off for non-experts). We aimed to assess the prevalence and predictive factors associated with CBD size ≥ 12 and 15 mm in naïve patients with malignant distal biliary obstruction (MDBO).

Patients and methods This was a prospective cohort study involving 22 centers with assessment of CBD diameter and subjective feasibility of the EUS-CDS performance in naïve jaundiced patients undergoing EUS evaluation for MDBO.

Results A total of 491 patients (mean age 69 ± 12 years) with mean serum bilirubin of 12.7 ± 6.6 mg/dL entered the final analysis. Dilation of the CBD ≥ 12 and 15 mm was detected in 78.8 % and 51.9 % of cases, respectively. Subjective feasibility of EUS-CDS was expressed by endosonographers in 91.2 % for a CBD ≥ 12 mm and in 96.5 % for a CBD ≥ 15 mm. On multivariate analysis, age (P < 0.01) and bilirubin level (P ≤ 0.001) were the only factors associated with both CBD dilation ≥ 12 and ≥ 15 mm. These variables were poorly associated with the extent of duct dilation; however, based on them a prediction model could be constructed that satisfactorily predicted CBD size ≥ 12 mm in patients at least 70 years and a bilirubin level ≥ 7 mg/dL.

Conclusions Our study showed that at presentation in a large cohort of patients with MDBO, EUS-CDS can be potentially performed in three quarters to half of cases by expert and less experienced endosonographers, respectively. Dedicated stents or devices with different designs able to overcome the limitations of existing electrocautery-enhanced LAMS for EUS-CDS are needed.


#

Introduction

Endoscopic ultrasound-guided biliary drainage (EUS-BD) is increasingly employed after endoscopic retrograde cholangiopancreatography (ERCP) failure in patients with malignant bile duct obstruction [1] [2]. Biliary drainage can be accomplished with a transgastric approach by performing a hepatico-gastrostomy (HGS) to the left intrahepatic biliary system, an antegrade stenting or rendezvous procedure if the guidewire can be negotiated through the papilla, or a transduodenal approach to the extrahepatic biliary system carrying out a choledochoduodenostomy (CDS).

As recently reported in a systematic review with meta-analysis, including nine studies with 483 patients, EUS-BD is associated with better clinical success, fewer adverse events (AEs), lower need for reintervention, and lower costs as compared to percutaneous biliary drainage [3]. More recently, three randomized controlled trials (RCTs) directly compared EUS-BD with ERCP as primary drainage for malignant distal biliary obstruction [4] [5] [6]. The first two studies were performed using a multistep procedure with needle puncture, guidewire placement, tract dilation and, finally, placement of a partially [4] or a fully covered [5] biliary self-expandable metal stent (SEMS). Both studies showed no differences between the two groups, but their conclusions were limited by the small sample size [7].

In the third study [6], 61 and 64 patients underwent ERCP and EUS-BD, respectively. In the latter group after puncture and guidewire placement in the biliary system, a dedicated device for both CDS (32 patients) and HGS (32 patients) was used. No difference in technical and clinical success rates was found. However, AEs (19.7 % vs. 6.3 %, P = 0.03), 6-month stent patency (48.9 % vs. 85.1 %, P = 0.001) and re-intervention rates (42.6 % vs. 15.6 %, P = 0.001) were all significantly in favor for the EUS-BD approach, after a mean follow-up of 165 days [6].

One available dedicated system for a single-step EUS-CDS procedure, avoiding the need for needle puncture and guidewire placement, is the AXIOS stent and electrocautery-enhanced delivery system in which a lumen apposing SEMS is mounted on an electrocautery-enhanced tip catheter (LA-SEMS). Because the delivery catheter acts as a cystotome, the system allows direct stent insertion into the common bile duct (CBD) lumen, where it is then released under complete EUS guidance or with partial endoscopic control [8] [9].

Different studies using the Axios stent reported EUS-CDS to be highly technically and clinically effective [9] [10] [11] [12] [13] [14] [15] [16] [17] [18] [19] [20]. The smallest sizes of the Axios stent (saddle diameter and length of 6 mm × 8 mm or 8 mm × 8 mm) are preferentially used for this procedure. Because of the risk of bile duct wall injury and misdeployment of the stent during release of the first flange, it is recommended that they be used in CBD diameters larger than 12 mm in expert hands and 15 mm in non-expert ones. This would theoretically limit the number of patients in whom the procedure can be safely performed when they first present with jaundice. However, up to now, no data on the prevalence rate of patients with a CBD diameter sufficient to accomplish an EUS-CDS at the presumed site using these stents are available.

To fill this gap, we conducted a prospective, multicenter cohort study in naïve patients with jaundice undergoing EUS to evaluate malignant distal biliary obstruction to assess the prevalence and predictive factors associated with a CBD ≥ 12 and ≥ 15 mm at the presumed site where EUS-CDS would be performed.


#

Patients and methods

This was an international, prospective, multicenter, observational study for which consecutive jaundiced patients who underwent EUS to evaluate suspected malignant distal biliary obstruction were enrolled between September 2018 and December 2019. [Table 1] shows the study selection criteria. Only patients with a confirmed diagnosis of malignancy were included in the final analysis.

Table 1

Inclusion and exclusion criteria for the patients in the study.

Inclusion criteria

  • Age ≥ 18 years

  • Signed informed consent of the study

  • Presence on cross-sectional imaging of a pancreatic, distal common bile duct, ampullary or adenopathic mass determining biliary obstruction

  • Referral for EUS staging or sampling of the tumor mass

  • Serum bilirubin level ≥ 3 mg/dL

Exclusion criteria

  • Formal contraindication to standard EUS examination

  • Lack of discernment or inability to sign the informed consent

  • Presence of altered anatomy from previous gastric surgery (e. g., Billroth II or Roux-en-Y anastomosis)

  • Previously performed sphincterotomy, biliary plastic stent or metal stent placement

  • Previous percutaneous drainage of the bile duct

  • Current pregnancy

  • Final diagnosis of benign disease

EUS, endoscopic ultrasound.

We estimated that about 20 centers would be needed, each including about 20 patients, to reach the sample size of 400 patients. Some of these centers, however, dropped out during the study period; therefore, a few additional ones were recruited, reaching a total of 22 enrolling centers.

Ethics committee approval was obtained in each study center and informed consent was obtained from all patients before the procedure. This trial was registered online at Clinicaltrials.gov (NCT03494023) prior to enrollment of the first patient.

Study procedures

An educational video explaining where and how to perform CBD measurement was sent to all centers before starting the enrollment. During EUS examination, performed with a therapeutic linear echoendoscope (Olympus GF-UCT180, Olympus Medical Corporation Europe, Hamburg, Germany; Pentax EG-3870UTK or EG38-J10UT, Pentax Medical Europe, Hamburg, Germany; or Fujifilm EG-580UT, Fujifilm Medical Systems Europe, Dusseldorf, Germany), careful evaluation of the bile duct obstruction site was performed. After identification and measurement of the mass lesion, the CBD was identified and followed from the point of obstruction up to the liver hilum. The study was centered on the measurement of the CBD diameter and assessment of the subjective feasibility of theoretical performance of EUS-CDS with the appropriate Axios stent ([Fig. 1]) at the level of the duodenal bulb corresponding to the mid CBD, where EUS-CDS would have been performed. Maximal attention was paid to avoid CBD compression by the EUS transducer during CBD measurement to minimize the risk of underestimating its diameter. The procedure was then continued with tissue acquisition and evaluation of tumor resectability. Tissue sampling and cytologic/histopathological evaluation, when performed, were handled according to local protocols. EUS-guided choledochoduodenostomy was not performed as part of the present study protocol.

Zoom Image
Fig. 1 Measurement of the common bile duct (CBD) diameter at the theoretical site of choledochoduodeno-anastomosis with the AXIOS Stent and Electrocautery Enhanced Delivery System. a Identification of the obstructive tumor (arrow). b, c Tracing of the common bile duct from the obstructive tumor upwards (*). d Identification of the suitable site for EUS-guided choledocoduodenostomy where measurement of the CBD diameter is performed (a).

#

Data collection

All data were collected in a patient case report form including: patient age and sex; interval of time (days) from the onset of jaundice to the day of the EUS procedure; serum levels of total bilirubin, alkaline phosphatase, gamma-GT and CA 19–9 performed within 24 hours before the procedure; and tumor size as measured by EUS.

Endosonographer experience in EUS-CDS was recorded and classified as extensive (> 40 EUS-CDS with Axios), moderate (between 20 and 40 cases) and limited (< 20 cases).

Patients with a positive EUS-FNA/FNB specimen were considered to have a malignant disease. In case of inconclusive or negative cyto-or histopathological results, additional data, such as the histopathological evaluation of the surgical specimen, repeated sampling procedures, or follow-up based on clinical disease evolution and repeat imaging study results were all utilized to establish the malignant nature of the existing biliary stricture.


#

Statistical analysis

Results were expressed as frequencies for categorical variables (further analyzed by chi-square or Fisher’s exact test when appropriate), mean and standard deviation (SD) for normally distributed continuous variables (analyzed by Student’s t-test), and median and interquartile range (IQR) for non-normally distributed continuous variables (analyzed by Mann-Whitney U test, or Kendall’s tau-b correlation). Univariate and multivariate (logistic regression) analyses were performed to determine whether any of the analyzed variables was associated with the CBD diameter. For logistic regression, independent variables associated with P ≤ 0.10 were included in the model by Enter method. Receiver operating characteristic (ROC) curve analyses were performed to identify cut-off values to be used for prediction. For the prediction model construction, we dichotomized the independent variables favoring the specificity. A two-sided significance of P < 0.05 was used throughout. The statistical analysis was performed using the SPSS for Windows software, version 20.0 (IBM Corp., Armonk, New York, United States).


#
#

Results

During the study period, 539 patients were assessed for eligibility. Forty-eight patients (8.9 %) were excluded from the overall analysis leading to the inclusion of 491 patients ([Fig. 2]). The mean number of analyzed patients enrolled per center (22 centers) was 22.3 ± 16.1.

Zoom Image
Fig. 2 Flowchart of the study.

The median interval of time between occurrence of jaundice and EUS examination was 10 days (range, 1–70). [Table 2] shows further details on blood test results, tumor characteristics, malignancy type, definitive diagnosis, and diagnostic methods used.

Table 2

Demographics, blood test results, and lesion characteristics of the 491 patients analyzed in the study.

Variable

Value

Gender, no (%)

  • male

277 (56.4 %)

  • female

214 (43.6 %%)

Mean age (range), years

69 ± 12, (29–94)

Blood test results

  • Mean serum bilirubin level ± SD (range), mg/dL

12.7 ± 6.7 (3–38)

  • Mean serum alkaline phosphatase level ± SD (range), times ULN

4.3 ± 2.6 (0.5–21.8)

  • Median serum GGT level (range), times ULN

11.8 (0.7–89.0)

  • Median serum CA 19–9 level (range), times ULN

(0–3172)

Median time from occurrence of jaundice (range), days

10 (1–70)

Mean tumor diameter, (mm)

29.0 ± 10.3

Final diagnoses, no (%)

  • Pancreatic adenocarcinoma

423 (86.2 %)

  • Cholangiocarcinoma

30 (6.1 %)

  • Ampullary adenocarcinoma

26 (5.3 %)

  • Compressive malignant lymph nodes

4 (0.8 %)

  • Pancreatic metastases from other malignancies

8 (1.6 %)

Diagnostic method used to determine malignancy, no (%)

  • EUS-FNA/FNB

446 (90.8 %)

  • Evaluation of surgically resected specimens

21 (4.3 %)

  • Compatible clinical follow-up

10 (2.0 %)

  • Endoscopic biopsies from duodenal invasion or from bile duct

14 (2.9 %)

Resectability assessment, no (%)

  • Resectable tumor

175 (35.6 %)

  • Locally advanced or metastatic

308 (62.8 %)

  • Not assessed because unfit for surgery

8 (1.6 %)

ULN, upper limit of normal; SD, standard deviation; GGT, gamma-glutamyl transpeptidase; EUS-FNA, endoscopic ultrasound-guided fine-needle aspiration; FNB, fine-needle biopsy.

Dilation of the CBD ≥ 12 mm was detected in 387 of 491 patients (78.8 %), whereas a CBD ≥ 15 mm was found in 255 cases (51.9 %) ([Fig. 3]). Overall, the endosonographers considered EUS-CDS technically feasible in 386 patients (78.6 %). In particular, a positive feasibility was expressed in 353 of 387 cases (91.2 %) for a CBD ≥ 12 mm and in 246 of 255 cases (96.5 %) for a CBD ≥ 15 mm. Interestingly, eight endosonographers indicated a possible attempt at EUS-CDS in 33 patients with CBD smaller than 12 mm. When stratified by endosonographer experience, EUS-CDS was considered possible in 138 of 164 patients (84.1 %) by five endosonographers with extensive expertise, which was significantly higher compared to 104 of 131 patients (79.4 %) evaluated by nine endosonographers with moderate expertise and 144 of 196 patients (73.5 %) evaluated by eight endosonographers with limited experience, respectively (P = 0.047).

Zoom Image
Fig. 3 Chart detailing the distribution of patients per extent of common bile duct (CBD) dilation.

Univariate analysis revealed that CBD dilation ≥ 12 mm was associated with age (mean 70.1 ± 11.3 vs. 65.6 ± 11.7 years; P = 0.001), bilirubin level (mean of 13.3 ± 6.71 vs. 10.5 ± 5.6 mg/dL; P < 0.001), degree of CA 19–9 elevation (median of 10.8 vs. 5.2 times the ULN; P = 0.012), and increased interval of time between onset of jaundice and EUS procedure (mean of 12.9 ± 9.8 vs. 10.0 ± 8.4 days; P = 0.001). On multivariate analysis, age (P = 0.002), bilirubin level (P = 0.001) and interval of time from jaundice to EUS procedure (P = 0.035) remained independent factors associated with CBD dilation of ≥ 12 mm.

The results of the univariate analysis for CBD dilation ≥ 15 mm were similar to those obtained for CBD dilation ≥ 12 mm, with age (mean of 70.9 ± 11.3 vs. 67.4 ± 11.6 years; P < 0.001), bilirubin level (mean of 13.8 ± 6.99 vs. 11.4 ± 5.90 mg/dL; P < 0.001), degree of CA 19–9 elevation (median of 10.97 vs. 8.19 times the ULN; P = 0.006), and interval of time between jaundice occurrence and EUS procedure (mean of 13.0 ± 9.9 vs. 11.6 ± 9.2 days; P = 0.048) as associated factors. On multivariate analysis, only age (P = 0.004) and bilirubin level (P < 0.001) remained associated with CBD dilation ≥ 15 mm.

Age and total bilirubin levels, factors independently associated on multivariate analysis to both CBD ≥ 12 mm and ≥ 15 mm, however, were poorly correlated with the extent of CBD dilation (age; P < 0.001, r = 0.19) (total bilirubin levels; P < 0.001, r = 0.25). AUROCs of 0.624 (95 % CI, 0.564–0.684) and 0.598 (95 % CI, 0.548–0.648) were found for bilirubin level and CBD ≥ 12 and ≥ 15 mm, while considering age and CBD dilation ≥ 12 and ≥ 15 mm, AUROCs of 0.607 (95 % CI, 0.547–0.666) and 0.590 (95 % CI, 0.540–0.641), respectively, were detected. We constructed a model based on cut-offs for age of 70 years and three levels of serum bilirubin (< 7 mg/dL, ≥ 7 mg/dL and < 14 mg/dL, and ≥ 14 mg/dL) in an attempt to predict the extent of CBD dilation for patients with malignant obstructive jaundice ([Table 3]). A clinically significant (> 80 % of cases) prediction for a CBD diameter ≥ 12 mm was found only for bilirubin ≥ 7 mg/dL and age of more than 70 years.

Table 3

Model for prediction of CBD dilation considering patient’s age and degree of jaundice.

Total bilirubin (mg/dL)

 < 7

 ≥ 7 and < 14

 ≥ 14

Age (years)

 < 70

 ≥ 70

 < 70

 ≥ 70

 < 70

 ≥ 70

No. of patients (%)

53 (11 %)

50 (11 %)

119 (24 %)

95 (19 %)

84 (17 %)

90 (18 %)

Probability of

CBD ≥ 12 mm

[95 % CI]

61 %

[57–65 %]

73 %

[61–85 %]

73 %

[64–81 %]

82 %

[73–89 %]

85 %

[77–93 %]

90 %

[84–96 %]

CBD ≥ 15 mm

[95 % CI]

31 %

[18–43 %]

42 %

[28–57 %]

48 %

[39–57 %]

60 %

[49–70 %]

53 %

[43–65 %]

65 %

[55–75 %]

Finally, concerning the theoretical feasibility of performing EUS-CDS, a correlation with the extent of CBD dilation was found both on univariate and multivariate analysis (P < 0.001) (mean of 16.07 ± 3.97 mm vs. 11.02 ± 2.69 mm), with an AUROC for CBD dilation extent predicting feasibility of CBD drainage of 0.880 (95 % CI, 0.841–0.918).


#

Discussion

We performed a prospecitve, multicenter, cohort study to assess the degree of CBD dilation on the possibility to perform EUS-CDS with the Axios stent and the associated predictive factors in a large cohort of jaundiced patients undergoing EUS for evaluation of distal malignant biliary obstruction. Overall, we found that CBD dilation of ≥ 12 mm and ≥ 15 mm, the two cut-offs suggested to safely perform EUS-CDS with the Axios stent, could be observed respectively in 78.8 % and 51.9 % of cases, with no strong predictive factors associated with them.

EUS-CDS, first reported by Giovannini et al. in 2001 [21], along with HGS represent valid alternatives to percutaneous drainage in patients with distal malignant biliary obstruction after failed ERCP [22]. Initial studies are also evaluating the role of EUS-BD versus ERCP as a primary treatment in this clinical setting [4] [5] [6]. The main theoretical advantage of EUS-BD over ERCP is placement of the stent above the tumor lesion (EUS-CDS) or distant to it (EUS-HGS), with the potential to reduce rates of stent occlusion due to tumor ingrowth or overgrowth. Whether this translates into a significantly better long-term stent patency of the EUS-BD approach is still to be determined.

For distal malignant biliary obstruction, the choice between performing EUS-CDS or EUS-HGS remains at the discretion of the endosonographer. EUS-CDS is certainly technically less demanding than EUS-HGS and appears to be safer [23]. In addition, most of the EUS-CDS studies did not include procedures performed utilizing the Axios stent specifically designed for EUS-BD and associated with a mean rate of AEs of 15.2 % ([Table 4]).

Table 4

Summary of the studies published as full papers reporting > 2 cases of EUS-guided biliary drainage after failed or not possible ERCP using the Axios stent in patients with distal malignant biliary obstruction.

Author (year)

Study type

No. of patients

A × ios stents used

Stent size (diameter × length) (mm)

Mean CBD diameter (mm)

Technical success (%)

Clinical success (%)

Mean Follow-up (days)

AEs (number of cases, %)

“Hot”

“Cold”

Brückner (2015) [10]

RS, SC

 5

 3

 2

6 × 8 in all

12.6 ± 3

5/5[1] (100)

5/5 (100)

9.8 ± 6.8

1/5 (20 %): stent dysfunction (1)

Anderloni (2016) [11]

CS, SC

 5[2]

 5

 0

NR

NR

5/5 (100)

5/5 (100)

7

NR

Kunda (2016) [9]

RS, MC

57

30

27

6 × 8 in 36

17.9 (range 8–35) (median)

56/57[3] (98.2)

54/56 (96.4)

151 ± 145

8/56 (14.3 %): duodenal perforation (1); stent migration (1); intraprocedural bleeding (1); transient cholangitis (1); stent occlusion or dysfunction (4)

8 × 8 in 2

10 × 10 in 16

15 × 10 in 2

Anderloni (2018) [13]

RS, SC

16[4]

16

 0

6 × 8 in 9

NR

15/16 (93.8)

14/15 (93.3)

138.7 ± 124.6

1/15 (6.7 %): fatal severe acute arterial bleeding (1)

8 × 8 in 4

10 × 10 in 3

Tsuchiya (2018) [14]

PS, MC

19

19

 0

6 × 8 in 10

17.3 ± 5.5

19/19 (100)

18/19 (94.7)

184 (range 12–819)

(median)

7/19 (36.8 %): fever (1); cholangitis (2, in 1 after stent obstruction); stent dysfunction/obstruction (3); stent dislodgement (1)

8 × 8 in 9

Puga (2019) [15]

PS, SC

 7

 7

 0

6 × 8 in 6

NR

7/7 (100)

5/8[5] (62.5)

66[6] (95 % CI, 7–127)

2/7 (28.6 %): fatal bleeding (2)

8 × 8 in 1

Jacques (2019) [16]

RS, MC

52[7]

52

 0

6 × 8 in 43

17.2 (range 9–25) (median)

46/52$ (88.5)

46/46 (100 %)

155

7/46 (15.2 %): cholangitis caused by obstruction or dysfunction of the stent in all

8 × 8 in 7

15 × 10 in 2

Anderloni (2019) [17]

RS, SC

46[4]

46

 0

6 × 8 in 21

17.3 ± 3.3

43/46 (93.5)

42/43 (97.7)

114.4 (95 % CI, 73.2–155.4)

5/43 (11.6 %): fatal bleeding (1); stent occlusion (3); stent migration (1)

8 × 8 in 19

10 × 10 in 6

El Chafic (2019) [18]

RS, MC

67

67

 0

10 × 10 in all

17.6 ± 3.6

64/67 (95.5)

40/40[8] (100 %)

119 (median)

11/64 (17.2 %)[9]: abdominal pain (2); peritonitis (1); bleeding (1); stent dysfunction/obstruction (7)

Fabbri (2019) [19]

CS, SC

 5[10]

 5

 0

8 × 8 in 4

20.2 ± 5.7

5/5 (100)

5/5 (100)

34.6 ± 8.1

None related to the procedure

10 × 10 in 1

Jacques (2020) [20]

RS, MC

70

70

 0

6 × 8 in 60

17.7 ± 5.0

69/70 (97.1)

69/69 (100 %)

153 (median)

8/69 (11.6 %): bleeding due to fistulotomy (1); stent migration (1); cholangitis (2, in 1 after stent occlusion); tumoral stent obstruction (4)

8 × 8 in 9

15 × 10 in 1

CBD, common bile duct; AEs, adverse events; RS, retrospective study; SC, single center; MC, multicenter; CS, case series; PS, prospective study; NR, not reported; EUS-CDS, EUS-guided choledochoduodenostomy; LA-SEMS, lumen-apposing self-e × pandable metal stents.

 1 In one of the patients, the distal flange release failed technically, but the stent system was successfully e × changed for a second system over the guidewire.


 2 Patients in this case series presented simultaneous duodenal and biliary malignant obstruction and were treated by single-session sequential EUS-guided choledochoduodenostomy and duodenal stenting.


 3 The technical failure was due to duodenal perforation occurring while performing dilation of the fistulous tract;


 4 It is possible that some of the patients were reported in both studies.


 5 Patients were reported as a cohort of eight including one patient in whom EUS-guided hepaticogastrostomy with a plastic stent was performed, and clinical success was not presented separately for the LA-SEMS stents.


 6 All patients died during follow-up.


 7 One of the patients presented with benign biliary obstruction (CBD stones).


 8 Only 40 patients who were followed-up for more than 4 weeks were considered for this end point.


 9 Biliary reinterventions for obstruction were needed in 7 (17.5 %), in 3 of 6 patients who underwent EUS-CDS with LA-SEMS alone versus 4 of 34 with LA-SEMS plus an a × is-orienting device.


10 In this case series, choledochoduodenostomy was performed as a bridge to surgery since all patients presented with malignancy causing biliary obstruction in a resectable stage.


Transformation few years ago of the delivery catheter of the Axios stent into a device with a cystotome on its tip has revolutionized the field of interventional EUS and the performance of EUS-CDS. Indeed, the procedure can be accomplished under full ultrasound control in one step, without a need for needle puncture or guidewire placement, limiting accessory exchange and risk of losing the position, causing procedural failure. The only real drawback of the 6 × 8 mm and 8 × 8 mm Axios stents most commonly used for EUS-CDS is represented by the size of the distal flange (14– and 17-mm diameter, respectively), i. e. the one placed into the CBD, which may not fit the size of the CBD to be drained in all cases.

Consequently, based on operator experience level, the suggested CBD size to perform safe drainage varies from ≥ 12 mm for experts and ≥ 15 mm for less experienced endosonographers. To investigate the impact of the CBD size on the perceived possibility of performing EUS-CDS with the Axios stent as a primary drainage procedure, we analyzed a cohort of 491 naïve patients presenting with jaundice (bilirubin levels ≥ 3 mg/dL) secondary to a malignant distal biliary obstruction. A CBD ≥ 12 mm and ≥ 15 mm, measured at the level of the duodenal bulb where EUS-CDS would be preferentially performed, was individually detected in 78.8 % and 51.9 % of cases. In other words, about three quarters and only half of the patients were potentially suitable for EUS-CDS by expert and less experienced endosonographers, respectively. This latter finding is particularly relevant in view of the scarce availability of hands-on training courses and training models for EUS-CDS, through which less experienced endosonographers can reach skills to perform drainages in cases of CBD dilation close to 12 mm. Indeed, some studies proposed that at least 50 EUS-CDS cases are needed for endosonographers to be considered experts [24], with a suggestion of restricting the performance of this procedure to only highly specialized centers [25]. Interestingly, some experts said that it was also possible to perform EUS-CDS on a CBD < 12 mm with the Axios stent. This is possible by gently pushing the catheter tip against the distal CBD wall while slowly opening the stent, thus making the CBD “bigger” or by entering the CBD with an angle that permits the catheter to be pushed upwards, where the stent can be opened safely vertically to the major axis of the CBD.

To assess the possibility of selecting patients before EUS, we performed univariate and multivariate analyses, which identified age and bilirubin levels as the only independent predictive factors for both CBD ≥ 12 mm and ≥ 15 mm at the theoretical site of EUS-CDS. Both variables, however, were found to be poorly associated with the extent of duct dilation, a finding that was further supported by the unsatisfactory results of the AUROCs, where no specific cut-off points with good sensitivity and specificity could be found for these two factors. This uncertainty also was supported by results from a predictive model we developed to apply to each new patient presenting with malignant distal obstructive jaundice. Indeed, this model worked satisfactorily only for predicting a CBD size ≥ 12 mm in patients at least 70 years old and with bilirubin levels between ≥ 7 mg/dL and 14 mg/dL or with higher bilirubin levels (range between 82 % to 90 %).

Taken together, all these data have important implications for the potential extended use of the Axios stent in all cases of malignant distal CBD obstruction. We strongly believe that single-step insertion stents with a different design, able to fit narrower CBDs to overcome the limitation we illustrated, need to be developed. Standard fully or partially covered biliary SEMS, which have been used in two RCTs and can fit any CBD [4] [5], might have an increased risk of migration because of the absence of forces exerted by the stented tumoral mass that keeps them in place when positioned transpapillary. In the RCT by Paik et al. [6], a SEMS featuring an uncovered portion with anchoring flaps to be placed into the CBD and a distal funnel-shaped uncovered wire mesh portion was successfully used, with only two cases of stent migration that were not specified if they had occurred during EUS-CDS or EUS-HGS. This stent, however, is mounted on an introducer without a cystotome capability and requires a multistep procedure with accessory exchange, which might be associated with an increased risk of procedural failure [6]. Moreover, data on reproducibility to fully assess the performance of this latter stent are lacking. Another possible approach would be to reduce the width of the inner flange of the Axios stent up to a value that can guarantee sufficient juxtaposing forces to avoid its migration and allow its use in the majority, if not all, cases of distal malignant CBD obstruction. This working process will hopefully transform EUS-CDS into a safer procedure, which can be learned and taught by the large majority of EUS performers, a prerequisite to bringing EUS-CDS to another level.

One major limitation of our study is that the CBD size measured with EUS was not compared with other imaging modalities, which was due to the fact that patients underwent different pre-EUS imaging tests. Another possible bias was that the study was conducted in many centers. However, assessment of CBD size by EUS was standardized among all the participants in the study, making the results reproducible.


#

Conclusions

In conclusion, our study demonstrated that in naïve patients with malignant distal CBD obstruction, the Axios stent theoretically can be used safely in about three quarters of the cases by experts and in about half the cases by non-expert endosonographers. However, no reliable predictive factors could be elucidated to indicate which patients will be fit for the procedure. Efforts to create dedicated stents or devices with a different design, able to overcome the existing limitations of the Axios stent for EUS-CDS, are needed.


#
#

Competing interests

Dr. Anderloni is a consultant for Boston Scientific, Olympus Medical and Medtronic. Dr. Fabbri is a consultant for Boston Scientific. Dr. Napoleon has held supported teaching sessions and had research collaboration with Boston Scientific. Dr. Poley served as a consultant for and received speaker and travel fees from Boston Scientific, Cook Endoscopy, and Pentax. Dr. Mutignani had a research collaboration with Boston Scientific. Dr. Palazzo is a consultant for Boston Scientific. Dr. Itoi is a speaker for Boston Scientific. Dr. Costamagna received research support from Cook Endoscopy and he currently is a member of Advisory Committees or review panels for Olympus Medical and Boston Scientific. Dr. Larghi received educational fees from Boston Scientific and Pentax.

  • References

  • 1 Kahaleh M, Artifon ELA, Perez-Miranda M. et al. EUS-guided drainage: Summary of therapeutic EUS consortium meeting. Endosc Ultrasound 2019; 8: 151-160
  • 2 Boulay BR, Lo SK. Endoscopic ultrasound-guided biliary drainage. Gastrointest Endosc Clin N Am 2018; 28: 171-185
  • 3 Sharaiha RZ, Khan MA, Kamal F. et al. Efficacy and safety of EUS-guided biliary drainage in comparison with percutaneous biliary drainage when ERCP fails: a systematic review and meta-analysis. Gastrointest Endosc 2017; 85: 904-914
  • 4 Park JK, Woo YS, Noh DH. et al. Efficacy of EUS-guided and ERCP-guided biliary drainage for malignant biliary obstruction: prospective randomized controlled study. Gastrointest Endosc 2018; 88: 277-282
  • 5 Bang JY, Navaneethan U, Hasan M. et al. Stent placement by EUS or ERCP for primary biliary decompression in pancreatic cancer: a randomized trial (with videos). Gastrointest Endosc 2018; 88: 9-17
  • 6 Paik WH, Lee TH, Park DH. et al. EUS-guided biliary drainage versus ERCP for the primary palliation of malignant biliary obstruction: a multicenter randomized clinical trial. Am J Gastroenterol 2018; 113: 987-997
  • 7 Frazzoni L, Fuccio L, Larghi A. EUS-guided biliary drainage versus ERCP for the primary treatment of malignant distal biliary obstruction: time for a large randomized study. Gastrointest Endosc 2018; 88: 571-572
  • 8 Attili F, Rimbaş M, Galasso D. et al. Fluoroless endoscopic ultrasound-guided biliary drainage after failed ERCP with a novel lumen-apposing metal stent mounted on a cautery-tipped delivery system. Endoscopy 2015; 47 Suppl 1: E619-E620
  • 9 Kunda R, Pérez-Miranda M, Will U. et al. EUS-guided choledochoduodenostomy for malignant distal biliary obstruction using a lumen-apposing fully covered metal stent after failed ERCP. Surg Endosc 2016; 30: 5002-5008
  • 10 Brückner S, Arlt A, Hampe J. Endoscopic ultrasound-guided biliary drainage using a lumen-apposing self-expanding metal stent: a case series. Endoscopy 2015; 47: 858-861
  • 11 Anderloni A, Buda A, Carrara S. et al. Single-session double-stent placement in concomitant malignant biliary and duodenal obstruction with a cautery-tipped lumen apposing metal stent. Endoscopy 2016; 48: E321-E322
  • 12 French JB, Coe AW, Pawa R. Endoscopic ultrasound-guided choledochoduodenostomy with a lumen-apposing, self-expandable fully covered metal stent for palliative biliary drainage. Clin J Gastroenterol 2016; 9: 79-85
  • 13 Anderloni A, Leo MD, Carrara S. et al. Endoscopic ultrasound-guided transmural drainage by cautery-tipped lumen-apposing metal stent: exploring the possible indications. Ann Gastroenterol 2018; 31: 735-741
  • 14 Tsuchiya T, Teoh AYB, Itoi T. et al. Long-term outcomes of EUS-guided choledochoduodenostomy using a lumen-apposing metal stent for malignant distal biliary obstruction: A prospective multicenter study. Gastrointest Endosc 2018; 87: 1138-1146
  • 15 Puga M, Pallarès N, Velásquez-Rodríguez J. et al. Endoscopic biliary drainage in unresectable biliary obstruction: the role of endoscopic ultrasound-guidance in a cohort study. Rev Esp Enferm Dig 2019; 111: 683-689
  • 16 Jacques J, Privat J, Pinard F. et al. Endoscopic ultrasound-guided choledochoduodenostomy with electrocautery-enhanced lumen-apposing stents: A retrospective analysis. Endoscopy 2019; 51: 540-547
  • 17 Anderloni A, Fugazza A, Troncone E. et al. Single-stage EUS-guided choledochoduodenostomy using a lumenapposing metal stent for malignant distal biliary obstruction. Gastrointest Endosc 2019; 89: 69-76
  • 18 El Chafic AH, Shah JN, Hamerski C. et al. EUS-Guided Choledochoduodenostomy for Distal Malignant Biliary Obstruction Using Electrocautery-Enhanced Lumen-Apposing Metal Stents: First US, Multicenter Experience. Dig Dis Sci 2019; 64: 3321-3327
  • 19 Fabbri C, Fugazza A, Binda C. et al. Beyond palliation: using EUS-guided choledochoduodenostomy with a lumen-apposing metal stent as a bridge to surgery. a case series. J Gastrointestin Liver Dis 2019; 28: 125-128
  • 20 Jacques J, Privat J, Pinard F. et al. EUS-guided choledochoduodenostomy using electrocautery-enhanced lumen-apposing metal stents: a French multicenter study after implementation of the technique (with video). Gastrointest Endosc 2020; 92: 134-141
  • 21 Giovannini M, Moutardier V, Pesenti C. et al. Endoscopic ultrasound-guided bilioduodenal anastomosis: a new technique for biliary drainage. Endoscopy 2001; 33: 898-900
  • 22 Rimbaş M, Larghi A, Kunda R. EUS-guided biliary drainage: Is it ready for prime time?. Endosc Ultrasound 2017; 6: S122-S126
  • 23 Hedjoudje A, Sportes A, Grabar S. et al. Outcomes of endoscopic ultrasound-guided biliary drainage: A systematic review and meta-analysis. United European Gastroenterol J 2019; 7: 60-68
  • 24 Poincloux L, Rouquette O, Buc E. et al. Endoscopic ultrasound-guided biliary drainage after failed ERCP: cumulative experience of 101 procedures at a single center. Endoscopy 2015; 47: 794-801
  • 25 Artifon ELA, Visconti TAC, Brunaldi VO. Choledochoduodenostomy: Outcomes and limitations. Endosc Ultrasound 2019; 8: S72-S78

Corresponding author

Alberto Larghi MD, PhD
Digestive Endoscopy Unit
Fondazione Policlinico Universitario A. Gemelli IRCCS – Università Cattolica del Sacro Cuore
Largo A. Gemelli 8, 00168
Rome
Italy   
Fax: +39/0630156581   

Publication History

Received: 04 April 2021

Accepted: 26 May 2021

Article published online:
12 November 2021

© 2021. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/)

Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany

  • References

  • 1 Kahaleh M, Artifon ELA, Perez-Miranda M. et al. EUS-guided drainage: Summary of therapeutic EUS consortium meeting. Endosc Ultrasound 2019; 8: 151-160
  • 2 Boulay BR, Lo SK. Endoscopic ultrasound-guided biliary drainage. Gastrointest Endosc Clin N Am 2018; 28: 171-185
  • 3 Sharaiha RZ, Khan MA, Kamal F. et al. Efficacy and safety of EUS-guided biliary drainage in comparison with percutaneous biliary drainage when ERCP fails: a systematic review and meta-analysis. Gastrointest Endosc 2017; 85: 904-914
  • 4 Park JK, Woo YS, Noh DH. et al. Efficacy of EUS-guided and ERCP-guided biliary drainage for malignant biliary obstruction: prospective randomized controlled study. Gastrointest Endosc 2018; 88: 277-282
  • 5 Bang JY, Navaneethan U, Hasan M. et al. Stent placement by EUS or ERCP for primary biliary decompression in pancreatic cancer: a randomized trial (with videos). Gastrointest Endosc 2018; 88: 9-17
  • 6 Paik WH, Lee TH, Park DH. et al. EUS-guided biliary drainage versus ERCP for the primary palliation of malignant biliary obstruction: a multicenter randomized clinical trial. Am J Gastroenterol 2018; 113: 987-997
  • 7 Frazzoni L, Fuccio L, Larghi A. EUS-guided biliary drainage versus ERCP for the primary treatment of malignant distal biliary obstruction: time for a large randomized study. Gastrointest Endosc 2018; 88: 571-572
  • 8 Attili F, Rimbaş M, Galasso D. et al. Fluoroless endoscopic ultrasound-guided biliary drainage after failed ERCP with a novel lumen-apposing metal stent mounted on a cautery-tipped delivery system. Endoscopy 2015; 47 Suppl 1: E619-E620
  • 9 Kunda R, Pérez-Miranda M, Will U. et al. EUS-guided choledochoduodenostomy for malignant distal biliary obstruction using a lumen-apposing fully covered metal stent after failed ERCP. Surg Endosc 2016; 30: 5002-5008
  • 10 Brückner S, Arlt A, Hampe J. Endoscopic ultrasound-guided biliary drainage using a lumen-apposing self-expanding metal stent: a case series. Endoscopy 2015; 47: 858-861
  • 11 Anderloni A, Buda A, Carrara S. et al. Single-session double-stent placement in concomitant malignant biliary and duodenal obstruction with a cautery-tipped lumen apposing metal stent. Endoscopy 2016; 48: E321-E322
  • 12 French JB, Coe AW, Pawa R. Endoscopic ultrasound-guided choledochoduodenostomy with a lumen-apposing, self-expandable fully covered metal stent for palliative biliary drainage. Clin J Gastroenterol 2016; 9: 79-85
  • 13 Anderloni A, Leo MD, Carrara S. et al. Endoscopic ultrasound-guided transmural drainage by cautery-tipped lumen-apposing metal stent: exploring the possible indications. Ann Gastroenterol 2018; 31: 735-741
  • 14 Tsuchiya T, Teoh AYB, Itoi T. et al. Long-term outcomes of EUS-guided choledochoduodenostomy using a lumen-apposing metal stent for malignant distal biliary obstruction: A prospective multicenter study. Gastrointest Endosc 2018; 87: 1138-1146
  • 15 Puga M, Pallarès N, Velásquez-Rodríguez J. et al. Endoscopic biliary drainage in unresectable biliary obstruction: the role of endoscopic ultrasound-guidance in a cohort study. Rev Esp Enferm Dig 2019; 111: 683-689
  • 16 Jacques J, Privat J, Pinard F. et al. Endoscopic ultrasound-guided choledochoduodenostomy with electrocautery-enhanced lumen-apposing stents: A retrospective analysis. Endoscopy 2019; 51: 540-547
  • 17 Anderloni A, Fugazza A, Troncone E. et al. Single-stage EUS-guided choledochoduodenostomy using a lumenapposing metal stent for malignant distal biliary obstruction. Gastrointest Endosc 2019; 89: 69-76
  • 18 El Chafic AH, Shah JN, Hamerski C. et al. EUS-Guided Choledochoduodenostomy for Distal Malignant Biliary Obstruction Using Electrocautery-Enhanced Lumen-Apposing Metal Stents: First US, Multicenter Experience. Dig Dis Sci 2019; 64: 3321-3327
  • 19 Fabbri C, Fugazza A, Binda C. et al. Beyond palliation: using EUS-guided choledochoduodenostomy with a lumen-apposing metal stent as a bridge to surgery. a case series. J Gastrointestin Liver Dis 2019; 28: 125-128
  • 20 Jacques J, Privat J, Pinard F. et al. EUS-guided choledochoduodenostomy using electrocautery-enhanced lumen-apposing metal stents: a French multicenter study after implementation of the technique (with video). Gastrointest Endosc 2020; 92: 134-141
  • 21 Giovannini M, Moutardier V, Pesenti C. et al. Endoscopic ultrasound-guided bilioduodenal anastomosis: a new technique for biliary drainage. Endoscopy 2001; 33: 898-900
  • 22 Rimbaş M, Larghi A, Kunda R. EUS-guided biliary drainage: Is it ready for prime time?. Endosc Ultrasound 2017; 6: S122-S126
  • 23 Hedjoudje A, Sportes A, Grabar S. et al. Outcomes of endoscopic ultrasound-guided biliary drainage: A systematic review and meta-analysis. United European Gastroenterol J 2019; 7: 60-68
  • 24 Poincloux L, Rouquette O, Buc E. et al. Endoscopic ultrasound-guided biliary drainage after failed ERCP: cumulative experience of 101 procedures at a single center. Endoscopy 2015; 47: 794-801
  • 25 Artifon ELA, Visconti TAC, Brunaldi VO. Choledochoduodenostomy: Outcomes and limitations. Endosc Ultrasound 2019; 8: S72-S78

Zoom Image
Fig. 1 Measurement of the common bile duct (CBD) diameter at the theoretical site of choledochoduodeno-anastomosis with the AXIOS Stent and Electrocautery Enhanced Delivery System. a Identification of the obstructive tumor (arrow). b, c Tracing of the common bile duct from the obstructive tumor upwards (*). d Identification of the suitable site for EUS-guided choledocoduodenostomy where measurement of the CBD diameter is performed (a).
Zoom Image
Fig. 2 Flowchart of the study.
Zoom Image
Fig. 3 Chart detailing the distribution of patients per extent of common bile duct (CBD) dilation.