J Neurol Surg A Cent Eur Neurosurg 2024; 85(03): 319-321
DOI: 10.1055/a-2103-7639
Technical Note

Microsurgical Clipping after Failed Contour Device Embolization of an Anterior Communicating Artery Aneurysm: Technical Note

1   Department of Neurosurgery, Christina Doppler Clinic, Paracelsus Medical University, Salzburg, Austria
2   Research Institute of Neurointervention, Paracelsus Medical University, Salzburg, Austria
,
Monika Killer-Oberpfalzer
2   Research Institute of Neurointervention, Paracelsus Medical University, Salzburg, Austria
,
Carlos M. Beredjiklian
1   Department of Neurosurgery, Christina Doppler Clinic, Paracelsus Medical University, Salzburg, Austria
,
Manuel Lunzer
1   Department of Neurosurgery, Christina Doppler Clinic, Paracelsus Medical University, Salzburg, Austria
› Author Affiliations

Abstract

Background Endovascular therapy has revolutionized the treatment of cerebral aneurysms in recent years and decades. So-called intrasaccular devices (i.e., Woven EndoBridge [WEB], MicroVention, Aliso Viejo, California, United States; or Contour, Cerus Neurovascular, Fremont, California, United States) are a promising endovascular technology, especially for wide-based aneurysms. However, long-term outcome data are currently particularly scarce for Contour and strategies for failed Contour cases are lacking. Here, we report the feasibility of microsurgical clipping after failed Contour device embolization.

Methods Feasibility of microsurgical clipping after failed aneurysm embolization with a Contour intrasaccular device was assessed in a patient.

Results We present the case of a 36-year-old male patient diagnosed with Hunt and Hess grade 1 subarachnoid hemorrhage from an anterior communicating artery aneurysm. The ruptured aneurysm was initially treated with the Contour device. After 3 months, angiographic imaging showed a clear aneurysm residual deemed not endovascularly accessible. The patient was then successfully clipped using microsurgical techniques. The patient was discharged with no neurologic abnormalities.

Conclusion After thorough bibliographical research, this presents the first published case report of microsurgical clipping after failed embolization with Contour. The main insights gained after clipping were that the Contour does not significantly disturb or hinder clipping. In contrast to coils in aneurysms to be clipped, the Contour can be easily compressed by the clip blades and does not have to be removed. In addition, the Contour had not migrated into the subarachnoid space and there was no abnormal scarring. Clipping appears to be a reasonable treatment strategy for failure of embolization with Contour if endovascular means are not suitable.



Publication History

Received: 03 January 2023

Accepted: 30 May 2023

Accepted Manuscript online:
31 May 2023

Article published online:
26 July 2023

© 2023. Thieme. All rights reserved.

Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany

 
  • References

  • 1 Jiang B, Paff M, Colby GP, Coon AL, Lin LM. Cerebral aneurysm treatment: modern neurovascular techniques. Stroke Vasc Neurol 2016; 1 (03) 93-100
  • 2 Dmytriw AA, Salem MM, Yang VXD. et al. Endosaccular flow disruption: a new frontier in endovascular aneurysm management. Neurosurgery 2020; 86 (02) 170-181
  • 3 Liebig T, Killer-Oberpfalzer M, Gal G. et al. The safety and effectiveness of the Contour Neurovascular System (Contour) for the treatment of bifurcation aneurysms: the CERUS study. Neurosurgery 2022; 90 (03) 270-277
  • 4 Akhunbay-Fudge CY, Deniz K, Tyagi AK, Patankar T. Endovascular treatment of wide-necked intracranial aneurysms using the novel Contour Neurovascular System: a single-center safety and feasibility study. J Neurointerv Surg 2020; 12 (10) 987-992
  • 5 Thormann M, Mpotsaris A, Behme D. Treatment of a middle cerebral artery bifurcation aneurysm with the novel Contour Neurovascular System compatible with 0.021″ catheters. Neuroradiol J 2021
  • 6 Heiferman DM, Peterson JC, Johnson KD. et al. Woven EndoBridge embolized aneurysm clippings: 2-dimensional operative video. Oper Neurosurg (Hagerstown) 2021; 21 (04) E365