Z Geburtshilfe Neonatol 2010; 214(2): 68-73
DOI: 10.1055/s-0030-1249613
Originalarbeit

© Georg Thieme Verlag KG Stuttgart · New York

Senkt die Kombination von fetaler Biometrie und MRT-Pelvimetrie die Rate an sekundären Sectiones?

Does a Combination of Foetal Biometry and Maternal MRI Pelvimetry Decrease the Frequency of Secondary Caesarean Section?T. Fasler1 , T. Burkhardt1 , J. Wisser1 , T. Keller2 , J. Kurmanavicius1
  • 1Klinik für Geburtshilfe, Universitätsspital Zürich, Schweiz
  • 2Klinik für Diagnostische Radiologie, Universitätsspital Zürich, Schweiz
Further Information

Publication History

eingereicht 16.12.2008

angenommen nach Überarbeitung 23.05.2009

Publication Date:
21 April 2010 (online)

Zusammenfassung

Ziel: Das Kopf-Becken-Missverhältnis (KBM) ist eine häufige Indikation für eine sekundäre Sectio. Das Geburtssimulationsprogramm Anapelvis (CREASO GmbH, Gilching, Deutschland) wurde entwickelt, um anhand pelvimetrischer und fetometrischer Daten ein KBM vorherzusagen. Das Ziel dieser retrospektiven Studie war, die Zuverlässigkeit des Programms an einem definiertem Risikokollektiv sowie den Einfluss der Qualität der präpartalen fetalen Gewichtsschätzung zu testen.

Patientinnen und Methodik: Ausgewertet wurden 162 Schwangerschaften mit klinischem Verdacht auf KBM oder Zustand nach Sectio caesarea mit einem Becken-Magnetresonanztomogramme (MRT). Eine fetale Ultraschallbiometrie erfolgte im Mittel sieben Tage vor Geburt. Anapelvis klassifiziert wie folgt: Gruppe 1: Geburtsstillstand, Gruppe 2: Spontangeburt potentiell möglich, Gruppe 3: Spontangeburt sicher möglich.

Ergebnisse: 40/162 Schwangere wurden per primärer Sectio caesarea entbunden, bei 122/162 war eine Spontangeburt geplant. Gruppe 1 (n=42): 6/42 (14%) wurden entgegen der Vorhersage vaginal entbunden. Gruppe 3 (n=37): tatsächlicher Geburtsmodus war bei 76% (28/37) eine sekundäre Sectio caesarea. Bei 7/43 Schwangeren der Gruppe 2 gab es eine vaginale Entbindung. Die Frauen der Gruppe 1 hatten signifikant kleiner Diameter interspinalis (100,1±9,4 mm vs. 109,6±7,1 mm, bzw. 100,1±9,4 mm vs. 109,4±7,3 mm, p<0,001). Der positive prädiktive Wert der Anapelvissoftware für eine sekundäre Sectio caesarea betrug 86%. Die genaueste sonografische Gewichtsschätzung [prozentualer Fehler (PE) −0,1%] war in der Gruppe mit einem prognostizierten Geburtsstillstand zu verzeichnen. In den Gruppen mit einer prognostizierten Spontangeburt wurde das Gewicht deutlich unterschätzt (PE −4,4%).

Schlussfolgerungen: Nur bei einem prognostizierten Geburtsstillstand ist das Simulationsergebnis hilfreich, denn dann kann mit einer hohen Wahrscheinlichkeit von einer sekundären Sectio ausgegangen werden. Die Qualität der Geburtssimulation durch Anapelvis geht in engem Zusammenhang mit der Qualität der präpartalen fetalen Biometrie einher.

Abstract

Objective: Cephalopelvic disproportion (CPD) is a frequent indication for secondary Caesarean section. The delivery simulation software Anapelvis was developed to predict a CPD on the basis of foetal ultrasound biometry and maternal pelvimetry data. The objective of this retrospective study was to analyse the predictive value of Anapelvis software in consideration of antenatal foetal biometry quality.

Patients and Methods: 162 pregnant women with suspected CPD who had undergone a magnetic resonance imaging pelvimetry were included in this study. The antenatal foetal biometry was carried out within a week before delivery.

Results: The positive predictive value (PPV) for arrest of delivery was 85.7% in the group of 79 pregnancies with planned vaginal delivery. Sensitivity was 56.3%, specificity 60.0% and negative predictive value (NPV) 24.3% accordingly. The highest accuracy [percent error (PE) −0.1%] of fetal weight estimation was found in the group where an arrest of delivery was predicted. The lowest accuracy (PE −4.4%) was detected in the group with the prediction of vaginal delivery.

Conclusions: Labour simulation software can be helpful only in such cases where an arrest of delivery was predicted. The accuracy of delivery simulation with the Anapelvis software was considerably affected by the quality of antenatal foetal ultrasound biometry.

Literatur

  • 1 Kurmanavicius J, Burkhardt T, Wisser J. et al . Ultrasonographic fetal weight estimation: accuracy of formulas and accuracy of examiners by birth weight from 500 to 5 000 g.  J Perinat Med. 2004;  32 155-161
  • 2 Keller TM, Rake A, Michel SC. et al . Obstetric MR pelvimetry: reference values and evaluation of inter- and intraobserver error and intraindividual variability.  Radiology. 2003;  227 37-43
  • 3 Kurmanavicius J, Wright EM, Royston P. et al . Fetal ultrasound biometry: 1. Head reference values.  Br J Obstet Gynaecol. 1999;  106 126-135
  • 4 Kurmanavicius J, Wright EM, Royston P. et al . Fetal ultrasound biometry: 2. Abdomen and femur length reference values.  Br J Obstet Gynaecol. 1999;  106 136-143
  • 5 Hadlock F, Harrist R, Sharman R. et al . Estimation of fetal weight with the use of head, body and femur measurements: a prospective study.  Am J Obstet Gynecol. 1985;  151 333-337
  • 6 Wischnik A, Werner T, Bohnhoff K. Prevention of Human Birth Trauma IInd Communication: Knowledge – Based Birth Planning and Visualisation by Means of Imaging Procedures and Simulation Aided by Personal Computer.  Geburtsh. u. Frauenheilk. 1999;  59 77-84
  • 7 Wischnik A, Hotzinger H, Lehmann Kj. et al . Applications of magnetic resonance tomography (MRT) in obstetrics.  Gynakologe. 1995;  28 321-328
  • 8 Forster C, Bechtold I, Melchert F. Clinical use of the birth simulation program „Anapelvis 2.0” for prediction of feto-maternal disproportion.  Zentralbl Gynakol. 2001;  123 465-468

Korrespondenzadresse

Tilo Burkhardt

Klinik für Geburtshilfe

Universitätsspital Zürich

Frauenklinikstraße 10

8091 Zürich

Schweiz

Phone: +41/44/255 51 48

Fax: +41/44/255 44 30

Email: Tilo.Burkhardt@usz.ch