Am J Perinatol 2011; 28(2): 111-116
DOI: 10.1055/s-0030-1263301
© Thieme Medical Publishers

An Observational Study of Early Neonatal Biochemical Parameters in Twins

Paul Henderson1 , David Cordiner1 , Ben Stenson1
  • 1Neonatal Unit, Simpson Centre for Reproductive Health, Royal Infirmary of Edinburgh, Edinburgh, UK
Further Information

Publication History

Publication Date:
10 August 2010 (online)

ABSTRACT

Early neonatal biochemical values are generally considered to reflect maternal values. However, studies have been inconclusive due to the statistical methods used. We hypothesized that there would not be important differences in plasma biochemistry between newborn twins, suggesting a common mechanism of control, and that differences between unrelated infant pairs would be greater. All twins over a 5-year period who had plasma biochemistry measured within 6 hours of birth were identified retrospectively. An unrelated control infant was matched to one of each twin pair. The 95% limits of agreement for plasma urea, creatinine, and sodium were calculated for twin pairs and unrelated matched infant pairs. Fifty-three twin pairs were studied. For urea, creatinine, and sodium, 95% of differences between twins were less than or equal to 1.5 mmol/L (8.9 mg/dL), 9.2 μmol/L (0.1 mg/dL), and 5.1 mmol/L (11.7 mg/dL), respectively. In unrelated infant pairs, the corresponding values were 4.0 mmol/L (24.3 mg/dL), 33.9 μmol/L (0.4 mg/dL), and 8.2 mmol/L (18.9 mg/dL). Differences between unrelated infant pairs were significantly wider than differences between twins (p < 0.001). This study has demonstrated a close and significant agreement in urea, sodium, and creatinine when measured soon after birth in twin pairs compared with unrelated infants, implying a common mechanism of control.

REFERENCES

  • 1 Lao T T, Loong E P, Chin R K, Lam Y M. Renal function in the newborn. Newborn creatinine related to birth weight, maturity and maternal creatinine.  Gynecol Obstet Invest. 1989;  28 70-72
  • 2 Nolte S, Mueller B, Pringsheim W. Serum α 1-microglobulin and β 2-microglobulin for the estimation of fetal glomerular renal function.  Pediatr Nephrol. 1991;  5 573-577
  • 3 Guignard J P, Drukker A. Why do newborn infants have a high plasma creatinine?.  Pediatrics. 1999;  103 e49
  • 4 Bland J M, Altman D G. Statistical methods for assessing agreement between two methods of clinical measurement.  Lancet. 1986;  1 307-310
  • 5 Arad I, Bar-Oz B, Peleg O. Early plasma creatinine values in discordant twins.  Twin Res. 2001;  4 215-218
  • 6 Blackburn S T. Maternal, Fetal & Neonatal Physiology: A Clinical Perspective. 3rd ed. St. Louis, MO: Elsevier; 2007: 102-104
  • 7 Stulc J. Placental transfer of inorganic ions and water.  Physiol Rev. 1997;  77 805-836
  • 8 West C R, Harding J E. Maternal water intoxication as a cause of neonatal seizures.  J Paediatr Child Health. 2004;  40 709-710
  • 9 Johansson S, Lindow S, Kapadia H, Norman M. Perinatal water intoxication due to excessive oral intake during labour.  Acta Paediatr. 2002;  91 811-814
  • 10 Mathot M, Maton P, Henrion E et al.. Pseudo-Bartter syndrome in a pregnant mother and her fetus.  Pediatr Nephrol. 2006;  21 1037-1040
  • 11 Gibson K J, Boyce A C, Karime B M, Lumbers E R. Maternal renal insufficiency alters plasma composition and renal function in the fetal sheep.  Am J Physiol Regul Integr Comp Physiol. 2007;  292 R1204-R1211
  • 12 Babay Z, Al-Wakeel J, Addar M et al.. Serum cystatin C in pregnant women: reference values, reliable and superior diagnostic accuracy.  Clin Exp Obstet Gynecol. 2005;  32 175-179
  • 13 Drukker A, Guignard J P. Renal aspects of the term and preterm infant: a selective update.  Curr Opin Pediatr. 2002;  14 175-182

Paul HendersonM.B. Ch.B. M.R.C.P.C.H. 

Department of Child Life and Health, University of Edinburgh

20 Sylvan Place, Edinburgh EH9 1UW, UK

Email: paul.henderson2@nhs.net

    >