Nuklearmedizin 1995; 34(03): 115-117
DOI: 10.1055/s-0038-1629766
Original Article
Schattauer GmbH

191mIr: Verteilung und Retention im Tierversuch[*]

191mIr: Distribution and Retention in Animal Experiments
K. J. A. Kairemo
1   Aus den Abteilungen für Klinische Chemie (Prof. Dr. Adlercreutz) und für Diagnostische Radiologie (Prof. Dr. Standertskjöld-Nordenstam), Universitätskrankenhaus Helsinki, Finnland; MAP Medical Technologies Inc., Jyväskylä, Finnland
,
M. S. Kestilä
1   Aus den Abteilungen für Klinische Chemie (Prof. Dr. Adlercreutz) und für Diagnostische Radiologie (Prof. Dr. Standertskjöld-Nordenstam), Universitätskrankenhaus Helsinki, Finnland; MAP Medical Technologies Inc., Jyväskylä, Finnland
,
R. I. Svahn
1   Aus den Abteilungen für Klinische Chemie (Prof. Dr. Adlercreutz) und für Diagnostische Radiologie (Prof. Dr. Standertskjöld-Nordenstam), Universitätskrankenhaus Helsinki, Finnland; MAP Medical Technologies Inc., Jyväskylä, Finnland
,
J. V. Hiltunen
1   Aus den Abteilungen für Klinische Chemie (Prof. Dr. Adlercreutz) und für Diagnostische Radiologie (Prof. Dr. Standertskjöld-Nordenstam), Universitätskrankenhaus Helsinki, Finnland; MAP Medical Technologies Inc., Jyväskylä, Finnland
› Author Affiliations
Further Information

Publication History

Eingegangen: 02 December 1994

in revidierter Form: 04 January 1994

Publication Date:
03 February 2018 (online)

Zusammenfassung

Der ultrakurzlebige Radionuklid 191nnlr (T1/2 = 4,96 s) kann aus einem 191 Os/191 111lr-Großleistungsgenerator mit sehr niedriger 191Os-Kontamination gewonnen werden. Es wurde direkt in die Schwanzvenen von Wistar-Ratten eluiert. Die Tiere wurden dynamisch (fünf Bilder/s) bis 40 s abgebildet. Die Untersuchung wurde bei jedem Tier fünfmal wiederholt. Die Ganzkörperretention und Biodistribution von 191Os wurde bei Ratten untersucht, die nach 1 bzw. 4 Tagen nach der Injektion seziert wurden. Die höchste Retentionsaktivität wurde in den Nieren und in der Milz, die nächsthöhere in der Muskulatur und in der Leber gefunden. Diese Werte zeigen, daß die Kontamination keineswegs gefährliche Werte erreicht und die Untersuchungen ohne Bedenken wiederholt werden können. Ferner waren die einzelnen Untersuchungen an den Ratten individuell wiederholbar, was andeutet, daß 191nnlr eine geeignete Substanz für nuklearmedizinische Angio-gramme ist.

Summary

Ultrashort-lived tracer 19lm|r (T1/2 = 4.92 s) can be obtained with a high yield from an 191 Os/191mlr generator with a low 191Os breakthrough. It was eluated directly into the tail veins of Wistar rats. These animals were imaged dynamically (five frames/s) up to 40 s. The measurement was repeated five times on each animal. The whole-body retention and biodistribution of 191Os was studied by sacrificing the rats at one and four days, respectively, after injection. The activity retained was highest in the kidneys and the spleen, followed by the muscles and the liver. These values indicate that the breakthrough is by no means dangerous and that investigations can be repeated immediately with a radiation exposure of no significance. Furthermore, all investigations in the same animal were reproducible, suggesting that 191nnlr might be a good tracer for nuclear angiograms.

* Teilweise vorgestellt bei der Jahrestagung der Deutschen Gesellschaft für Nuklearmedizin, Kiel, 27.-30. April 1994.


 
  • Literatur

  • 1 Brihaye C, Butler TA, Knapp FF. et al. A new 191”Os/191mTr radionuclide generator system using activated carbon. J Nucl Med 1986; 27: 380-7.
  • 2 Cheng C, Treves S, Samuel A. et al. A new osmium-191 → iridium-191m generator. J Nucl Med 1980; 21: 1169-75.
  • 3 Heller GV, Treves S, Parker JA. Comparison of iridium-191m with technetium-99m for first pass radionuclide angiocardiographic evaluation of right and left ventricular function in adults. J Am Coll Cardiol 1986; 7: 1295-302.
  • 4 Hellman C, Zafrir N, Shimoni A. et al. Evaluation of ventricular function with first-pass l9lmIr radionuclide angiography. J Nucl Med 1989; 30: 450-7.
  • 5 Packard AB, Treves ST, O’Brien GM, Lim SK. An osmium-191/iridium-]91m radionuclide generator using an oxalato os-mate parent complex. J Nucl Med 1987; 28: 1571-6.
  • 6 Weininger J, Issachar D, Lubin E, Zabari M, Trumper J. Influence of pH adjustment agents on the biologic behavior of osmium-191 impurity in iridium-191m generator eluates. J Nucl Med 1990; 31: 523-5.
  • 7 Yano Y, Anger HO. Ultrashort-lived radioisotopes for visualizing blood and organs. JNucl Med 1968; 9: 2-6.