J Neurol Surg B Skull Base 2018; 79(06): 593-598
DOI: 10.1055/s-0038-1642032
Original Article
Georg Thieme Verlag KG Stuttgart · New York

Comparison of Constructive Interference in Steady-State and T1-Weighted MRI Sequence at Detecting Pituitary Adenomas in Cushing's Disease Patients

Min Lang
1   School of Medicine, Case Western Reserve University, Cleveland, Ohio, United States
2   Department of Neurosurgery, Neurological Institute, Cleveland Clinic, Cleveland, Ohio, United States
,
Ghaith Habboub
2   Department of Neurosurgery, Neurological Institute, Cleveland Clinic, Cleveland, Ohio, United States
3   Minimally Invasive Cranial Base and Pituitary Surgery Program, Rose Ella Burkhardt Brain Tumor and Neuro-Oncology Center, Cleveland Clinic, Cleveland, Ohio, United States
,
Doksu Moon
4   Department of Diagnostic Radiology, Imaging Institute, Cleveland Clinic, Cleveland, Ohio, United States
,
Abin Bandyopadhyay
4   Department of Diagnostic Radiology, Imaging Institute, Cleveland Clinic, Cleveland, Ohio, United States
,
Danilo Silva
2   Department of Neurosurgery, Neurological Institute, Cleveland Clinic, Cleveland, Ohio, United States
3   Minimally Invasive Cranial Base and Pituitary Surgery Program, Rose Ella Burkhardt Brain Tumor and Neuro-Oncology Center, Cleveland Clinic, Cleveland, Ohio, United States
,
Laurence Kennedy
5   Department of Endocrinology, Diabetes, and Metabolism, Cleveland Clinic, Cleveland, Ohio, United States
,
Varun R. Kshettry
2   Department of Neurosurgery, Neurological Institute, Cleveland Clinic, Cleveland, Ohio, United States
3   Minimally Invasive Cranial Base and Pituitary Surgery Program, Rose Ella Burkhardt Brain Tumor and Neuro-Oncology Center, Cleveland Clinic, Cleveland, Ohio, United States
6   Section of Rhinology, Sinus, and Skull Base Surgery, Head and Neck Institute, Cleveland Clinic, Cleveland, Ohio, United States
,
Pablo F. Recinos
2   Department of Neurosurgery, Neurological Institute, Cleveland Clinic, Cleveland, Ohio, United States
3   Minimally Invasive Cranial Base and Pituitary Surgery Program, Rose Ella Burkhardt Brain Tumor and Neuro-Oncology Center, Cleveland Clinic, Cleveland, Ohio, United States
6   Section of Rhinology, Sinus, and Skull Base Surgery, Head and Neck Institute, Cleveland Clinic, Cleveland, Ohio, United States
› Institutsangaben

Funding None.
Weitere Informationen

Publikationsverlauf

08. November 2017

03. März 2018

Publikationsdatum:
10. Mai 2018 (online)

Preview

Abstract

Background T1-weighted magnetic resonance imaging (MRI) remains the standard pituitary imaging sequence. However, up to 50% of pituitary adenomas are missed with standard imaging in Cushing's disease (CD) patients. Utility of other imaging sequences needs be explored.

Objective To compare a T2-gradient echo sequence, constructive interference in steady state (CISS), with a contrast-enhanced (CE) T1-weighted sequence, volume-interpolated breath-hold examination (VIBE), in the detection of pituitary adenomas in CD patients.

Design Retrospective analysis of CD patients who underwent endoscopic transsphenoidal pituitary adenomectomy at our institution.

Patients and Measurement Twelve patients were included in the study. Two neuroradiologists, who were blinded to the patients' clinical and surgical findings, independently reviewed the CE-VIBE and CISS images. Localization of pituitary adenoma from imaging was compared with intraoperative localization.

Results The averaged sensitivity of detecting pituitary adenoma in CD patients was not significantly different between CE-VIBE sequence (63%) and CISS sequence (54%). The positive predictive value was 75% (Observer A) and 100% (Observer B) with CE-VIBE sequence, and 64% (Observer A) and 100% (Observer B) with CISS sequence. In two patients, pituitary adenoma was easily localized with CISS sequence but hard to detect with CE-VIBE sequence. In two other patients, the adenoma was much better delineated on CE-VIBE sequence.

Conclusion In our series, the addition of CISS sequence to T1-weighted MRI imaging protocols improved the detection of pituitary adenomas in CD patients. CISS sequence may be a useful adjunct to T1-weighted pituitary MRI protocols and an appropriate alternative for patients with gadolinium contraindications.

Disclosures

Pablo F. Recinos is on the scientific advisory board of Acera, Inc.


Varun R. Kshettry was a recent consultant for Medprin.