J Knee Surg 2021; 34(03): 338-350
DOI: 10.1055/s-0039-1696656
Original Article

Meta-analysis Comparing Allograft to Synthetic Reconstruction for Extensor Mechanism Disruption after Total Knee Arthroplasty

1   Department of Orthopedics, University of Massachusetts Medical School, Worcester, Massachusetts
,
Tejbir S. Pannu
2   Levitetz Department of Orthopaedic Surgery, Cleveland Clinic Florida, Weston, Florida
,
Jesus M. Villa
2   Levitetz Department of Orthopaedic Surgery, Cleveland Clinic Florida, Weston, Florida
,
Michael Firtha
3   Department of Orthopedics, Cleveland Clinic, Cleveland, Ohio
,
Aldo M. Riesgo
2   Levitetz Department of Orthopaedic Surgery, Cleveland Clinic Florida, Weston, Florida
,
Carlos A. Higuera
2   Levitetz Department of Orthopaedic Surgery, Cleveland Clinic Florida, Weston, Florida
› Author Affiliations

Abstract

Extensor mechanism disruption following total knee arthroplasty (TKA) is a devastating complication that causes high failure rates. There is controversy on what is the best way to do an extensor mechanism reconstruction. This study aims to compare both allograft and synthetic reconstructive techniques for success, reoperation, and infection rates and functional outcomes. The search on PubMed, MEDLINE, Embase, BIOSIS, and Cochrane databases was performed on March 15, 2019, using the following keyword groups: (1) “extensor mechanism” and “total knee arthroplasty,” (2) “extensor mechanism” and “knee arthroplasty,” (3) “extensor mechanism” and “revision total knee arthroplasty,” and (4) “extensor mechanism” and “revision knee arthroplasty”. Only studies on extensor mechanism disruption after TKA that included sufficient data to compare these two surgical techniques were included. Meta-analysis was performed with random effect model using the DerSimonian–Laird method. Thirty studies were included. The overall success rate of the reconstruction was 73.3% (95% confidence interval [CI]: 0. 651, 0.814). The success rate of allograft (72.8%, 95% CI: 0.626, 0.829) was not significantly different from synthetic material (78%, 95% CI: 0.707, 0.852, p = 0.416). There was no significant difference in revision rates between allograft (14.2%, 95% CI: 0.095, 0.189) and synthetic material (16%, 95% CI: 0.096, 0.223, p = 0.657). The overall relative risk of infection was 4.301 (95% CI: 1.885, 9.810). There was no significant difference in relative risk of infection between allograft (3.886, 95% CI: 1.269, 11.903) and synthetic material (4.851, 95% CI: 1.433, 16.419, p = 0.793). No statistically significant difference was found in mean postoperative Knee Society score (73.109 [95% CI: 67.296, 78.922] vs. 72.679 [95% CI: 69.184, 76.173], p = 0.901) between allograft and mesh reconstruction groups. There were no significant differences in overall failures, infections, functional outcomes, or revision reconstructions between allograft and synthetic material extensor mechanism reconstructions. Our results demonstrate the difficulty in treating this serious injury, independent of technique, as well as the significant risk for overall failure and infection.



Publication History

Received: 30 October 2018

Accepted: 15 July 2019

Article published online:
30 August 2019

© 2019. Thieme. All rights reserved.

Thieme Medical Publishers, Inc.
333 Seventh Avenue, 18th Floor, New York, NY 10001, USA

 
  • References

  • 1 Lim CT, Amanatullah DF, Huddleston III JI. et al. Reconstruction of disrupted extensor mechanism after total knee arthroplasty. J Arthroplasty 2017; 32 (10) 3134-3140
  • 2 Barrack RL, Stanley T, Allen Butler R. Treating extensor mechanism disruption after total knee arthroplasty. Clin Orthop Relat Res 2003; (416) 98-104
  • 3 Emerson Jr RH, Head WC, Malinin TI. Reconstruction of patellar tendon rupture after TKA with an extensor mechanism allograft. Clin Orthop Relat Res 1990; (260) 154-161
  • 4 Ricciardi BF, Oi K, Trivellas M, Lee YY, Della Valle AG, Westrich GH. Survivorship of extensor mechanism allograft reconstruction after total knee arthroplasty. J Arthroplasty 2017; 32 (01) 183-188
  • 5 Le DH, Goodman SB, Maloney WJ, Huddleston JI. Current modes of failure in TKA: infection, instability, and stiffness predominate. Clin Orthop Relat Res 2014; 472 (07) 2197-2200
  • 6 Dobbs RE, Hanssen AD, Lewallen DG, Pagnano MW. Quadriceps tendon rupture after total knee arthroplasty. Prevalence, complications, and outcomes. J Bone Joint Surg Am 2005; 87 (01) 37-45
  • 7 Thiele K, Perka C, Matziolis G, Mayr HO, Sostheim M, Hube R. Current failure mechanisms after knee arthroplasty have changed: polyethylene wear is less common in revision surgery. J Bone Joint Surg Am 2015; 97 (09) 715-720
  • 8 Burnett RS, Berger RA, Paprosky WG, Della Valle CJ, Jacobs JJ, Rosenberg AG. Extensor mechanism allograft reconstruction after total knee arthroplasty. A comparison of two techniques. J Bone Joint Surg Am 2004; 86 (12) 2694-2699
  • 9 Jaureguito JW, Dubois CM, Smith SR, Gottlieb LJ, Finn HA. Medial gastrocnemius transposition flap for the treatment of disruption of the extensor mechanism after total knee arthroplasty. J Bone Joint Surg Am 1997; 79 (06) 866-873
  • 10 Browne JA, Hanssen AD. Reconstruction of patellar tendon disruption after total knee arthroplasty: results of a new technique utilizing synthetic mesh. J Bone Joint Surg Am 2011; 93 (12) 1137-1143
  • 11 Busfield BT, Huffman GR, Nahai F, Hoffman W, Ries MD. Extended medial gastrocnemius rotational flap for treatment of chronic knee extensor mechanism eficiency in patients with and without total knee arthroplasty. Clin Orthop Relat Res 2004; Nov;(428): 190-197
  • 12 Abdel MP, Salib CG, Mara KC, Pagnano MW, Perry KI, Hanssen AD. Extensor mechanism reconstruction with use of Marlex mesh: a series study of 77 total knee arthroplasties. J Bone Joint Surg Am 2018; 100 (15) 1309-1318
  • 13 Perry KI, Salib CG, Larson DR, Pagnano MW, Abdel MP, Hanssen AD. Two-stage exchange and Marlex-mesh reconstruction for infection with extensor mechanism disruption after total knee arthroplasty. J Bone Joint Surg Am 2018; 100 (17) 1482-1489
  • 14 Shau D, Patton R, Patel S, Ward L, Guild III G. Synthetic mesh vs. allograft extensor mechanism reconstruction in total knee arthroplasty - a systematic review of the literature and meta-analysis. Knee 2018; 25 (01) 2-7
  • 15 Wallace BC, Schmid CH, Lau J, Trikalinos TA. Meta-Analyst: software for meta-analysis of binary, continuous and diagnostic data. BMC Med Res Methodol 2009; 9 (01) 80
  • 16 Nazarian Jr DG, Booth Jr RE. Extensor mechanism allografts in total knee arthroplasty. Clin Orthop Relat Res 1999; (367) 123-129
  • 17 Nodzo SR, Rachala SR. Polypropylene mesh augmentation for complete quadriceps rupture after total knee arthroplasty. Knee 2016; 23 (01) 177-180
  • 18 Hozo SP, Djulbegovic B, Hozo I. Estimating the mean and variance from the median, range, and the size of a sample. BMC Med Res Methodol 2005; 5: 13
  • 19 Brown NM, Murray T, Sporer SM, Wetters N, Berger RA, Della Valle CJ. Extensor mechanism allograft reconstruction for extensor mechanism failure following total knee arthroplasty. J Bone Joint Surg Am 2015; 97 (04) 279-283
  • 20 Diaz-Ledezma C, Orozco FR, Delasotta LA, Lichstein PM, Post ZD, Ong AC. Extensor mechanism reconstruction with Achilles tendon allograft in TKA: results of an abbreviate rehabilitation protocol. J Arthroplasty 2014; 29 (06) 1211-1215
  • 21 Courtney PM, Edmiston TA, Pflederer CT, Levine BR, Gerlinger TL. Is there any role for direct repair of extensor mechanism disruption following total knee arthroplasty?. J Arthroplasty 2018; 33 (7S): S244-S248
  • 22 Ormaza A, Moreta J, Mosquera J, de Ugarte OS, Mozos JL. Chronic quadriceps tendon rupture after total knee arthroplasty augmented with synthetic mesh. Orthopedics 2017; 40 (01) 38-42
  • 23 Llombart Blanco R, Valentí A, Díaz de Rada P, Mora G, Valentí JR. Reconstruction of the extensor mechanism with fresh-frozen tendon allograft in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 2014; 22 (11) 2771-2775
  • 24 Boettner F, Bou Monsef J. Achilles tendon allograft for augmentation of the Hanssen patellar bone grafting. Knee Surg Sports Traumatol Arthrosc 2015; 23 (04) 1035-1038