J Knee Surg 2021; 34(07): 717-720
DOI: 10.1055/s-0039-1700843
Original Article

Agreement and Reliability of Lateral Patellar Tilt and Displacement following Total Knee Arthroplasty with Patellar Resurfacing

John P. Kleimeyer
1   Department of Orthopaedic Surgery, Stanford University School of Medicine, Redwood City, California
,
Thomas J. McQuillan
1   Department of Orthopaedic Surgery, Stanford University School of Medicine, Redwood City, California
,
Diren Arsoy
1   Department of Orthopaedic Surgery, Stanford University School of Medicine, Redwood City, California
,
1   Department of Orthopaedic Surgery, Stanford University School of Medicine, Redwood City, California
,
Derek F. Amanatullah
1   Department of Orthopaedic Surgery, Stanford University School of Medicine, Redwood City, California
› Author Affiliations
Funding None.

Abstract

Patellar position and alignment may be measured on routine axial radiographs by various techniques; however, the agreement and reliability of such measurements with a resurfaced patella remain unknown. This study evaluated the range and reliability of lateral patellar tilt and lateral patellar displacement following total knee arthroplasty (TKA) with a resurfaced patella among three observers on 45° Merchant view in 139 TKAs. Intraclass correlation coefficient (ICCs) were used to evaluate intraobserver agreement (IOA) and inter-rater reliability (IRR). IRR was high between each of the observers for lateral patellar tilt (ICC = 0.8) and lateral patellar displacement (ICC = 0.87). IOA was also high upon repeat measurement for the same observer for lateral patellar tilt (ICC ≥ 0.90) and lateral patellar displacement (ICC ≥ 0.86). Therefore, lateral patellar tilt and lateral patellar displacement are reproducible measurements of patellar position on a Merchant axial radiograph following a well-functioning TKA with a resurfaced patella.



Publication History

Received: 04 June 2019

Accepted: 18 September 2019

Article published online:
07 November 2019

© 2019. Thieme. All rights reserved.

Thieme Medical Publishers, Inc.
333 Seventh Avenue, 18th Floor, New York, NY 10001, USA

 
  • References

  • 1 Shan L, Shan B, Suzuki A, Nouh F, Saxena A. Intermediate and long-term quality of life after total knee replacement: a systematic review and meta-analysis. J Bone Joint Surg Am 2015; 97 (02) 156-168
  • 2 Cushnaghan J, Bennett J, Reading I. et al. Long-term outcome following total knee arthroplasty: a controlled longitudinal study. Ann Rheum Dis 2009; 68 (05) 642-647
  • 3 Brander VA, Stulberg SD, Adams AD. et al. Predicting total knee replacement pain: a prospective, observational study. Clin Orthop Relat Res 2003; (416) 27-36
  • 4 Baker PN, van der Meulen JH, Lewsey J, Gregg PJ. National Joint Registry for England and Wales, Data from the National Joint Registry for England and Wales. The role of pain and function in determining patient satisfaction after total knee replacement. J Bone Joint Surg Br 2007; 89 (07) 893-900
  • 5 Heck DA, Robinson RL, Partridge CM, Lubitz RM, Freund DA. Patient outcomes after knee replacement. Clin Orthop Relat Res 1998; (356) 93-110
  • 6 Petersen W, Rembitzki IV, Brüggemann GP. et al. Anterior knee pain after total knee arthroplasty: a narrative review. Int Orthop 2014; 38 (02) 319-328
  • 7 Malo M, Vince KG. The unstable patella after total knee arthroplasty: etiology, prevention, and management. J Am Acad Orthop Surg 2003; 11 (05) 364-371
  • 8 Sensi L, Buzzi R, Giron F, De Luca L, Aglietti P. Patellofemoral function after total knee arthroplasty: gender-related differences. J Arthroplasty 2011; 26 (08) 1475-1480
  • 9 Healy WL, Wasilewski SA, Takei R, Oberlander M. Patellofemoral complications following total knee arthroplasty. Correlation with implant design and patient risk factors. J Arthroplasty 1995; 10 (02) 197-201
  • 10 Dalury DF, Pomeroy DL, Gorab RS, Adams MJ. Why are total knee arthroplasties being revised?. J Arthroplasty 2013; 28 (8, Suppl): 120-121
  • 11 Nizard RS, Biau D, Porcher R. et al. A meta-analysis of patellar replacement in total knee arthroplasty. Clin Orthop Relat Res 2005; (432) 196-203
  • 12 Pakos EE, Ntzani EE, Trikalinos TA. Patellar resurfacing in total knee arthroplasty. A meta-analysis. J Bone Joint Surg Am 2005; 87 (07) 1438-1445
  • 13 He J-Y, Jiang L-S, Dai L-Y. Is patellar resurfacing superior than nonresurfacing in total knee arthroplasty? A meta-analysis of randomized trials. Knee 2011; 18 (03) 137-144
  • 14 Fu Y, Wang G, Fu Q. Patellar resurfacing in total knee arthroplasty for osteoarthritis: a meta-analysis. Knee Surg Sports Traumatol Arthrosc 2011; 19 (09) 1460-1466
  • 15 Pilling RWD, Moulder E, Allgar V, Messner J, Sun Z, Mohsen A. Patellar resurfacing in primary total knee replacement: a meta-analysis. J Bone Joint Surg Am 2012; 94 (24) 2270-2278
  • 16 Chen K, Li G, Fu D, Yuan C, Zhang Q, Cai Z. Patellar resurfacing versus nonresurfacing in total knee arthroplasty: a meta-analysis of randomised controlled trials. Int Orthop 2013; 37 (06) 1075-1083
  • 17 Garcia RM, Kraay MJ, Goldberg VM. Isolated resurfacing of the previously unresurfaced patella total knee arthroplasty. J Arthroplasty 2010; 25 (05) 754-758
  • 18 Gomes LS, Bechtold JE, Gustilo RB. Patellar prosthesis positioning in total knee arthroplasty. A roentgenographic study. Clin Orthop Relat Res 1988; (236) 72-81
  • 19 Heesterbeek PJ, Beumers MP, Jacobs WC, Havinga ME, Wymenga AB. A comparison of reproducibility of measurement techniques for patella position on axial radiographs after total knee arthroplasty. Knee 2007; 14 (05) 411-416
  • 20 Bindelglass DF, Cohen JL, Dorr LD. Patellar tilt and subluxation in total knee arthroplasty. Relationship to pain, fixation, and design. Clin Orthop Relat Res 1993; (286) 103-109
  • 21 Berger RA, Crossett LS, Jacobs JJ, Rubash HE. Malrotation causing patellofemoral complications after total knee arthroplasty. Clin Orthop Relat Res 1998; (356) 144-153
  • 22 Katchburian MV, Bull AM, Shih Y-F, Heatley FW, Amis AA. Measurement of patellar tracking: assessment and analysis of the literature. Clin Orthop Relat Res 2003; (412) 241-259
  • 23 Gasparini G, Familiari F, Ranuccio F. Patellar malalignment treatment in total knee arthroplasty. Joints 2013; 1 (01) 10-17
  • 24 Matsuda S, Miura H, Nagamine R, Urabe K, Hirata G, Iwamoto Y. Effect of femoral and tibial component position on patellar tracking following total knee arthroplasty: 10-year follow-up of Miller-Galante I knees. Am J Knee Surg 2001; 14 (03) 152-156
  • 25 Kim JH, Yoo B-W, Kim CW. Influence of the rotational alignment of the femoral and patellar components on patellar tilt in total knee arthroplasty. Knee Surg Relat Res 2015; 27 (03) 163-167
  • 26 Laughlin RT, Werries BA, Verhulst SJ, Hayes JM. Patellar tilt in total knee arthroplasty. Am J Orthop 1996; 25 (04) 300-304
  • 27 van Houten AH, Heesterbeek PJ, Wymenga AB. Patella position is not a determinant for anterior knee pain 10 years after balanced gap total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 2016; 24 (08) 2656-2662