Novel Cardioplegia Delivery in Patients with Severe Aortic Regurgitation
Funding None.

Abstract
During aortic valve replacement (AVR) in patients with severe aortic regurgitation (AR), repeated delivery of cardioplegia into the coronary ostia using a routine infusion cannula may induce coronary ostial injury. This study aims to introduce a new no-touch delivery method with reduced time and similar or better outcomes. Preliminary results have shown that no-touch cardioplegia delivery method was a simple, safe, and effective approach for cardioplegia infusion during AVR in patients with severe AR.
Statement of Ethics
The Local Research Ethics Committee approved the procedures relating to treatment and data collection, and informed consent was obtained from each patient.
Disclosure
None.
Publication History
Received: 05 March 2020
Accepted: 27 April 2020
Article published online:
11 July 2020
© 2020. Thieme. All rights reserved.