Zahnmedizin up2date, Table of Contents Zahnmedizin up2date 2016; 10(04): 359-380DOI: 10.1055/s-0042-104524 Prothetik Georg Thieme Verlag KG Stuttgart · New York Abformung – konventionell versus digital David Zügel , Ralph G. Luthardt , Michael R. Graf , Heike Rudolph Recommend Article Abstract Buy Article All articles of this category Full Text References Literatur 1 Boening KW, Wolf BH, Schmidt AE et al. Clinical fit of Procera AllCeram crowns. J Prosthet Dent 2000; 84: 419-424 2 Felton DA, Kanoy BE, Bayne SC et al. Effect of in vivo crown margin discrepancies on periodontal health. J Prosthet Dent 1991; 65: 357-364 3 Sorensen SE, Larsen IB, Jorgensen KD. Gingival and alveolar bone reaction to marginal fit of subgingival crown margins. Scand J Dent Res 1986; 94: 109-114 4 Geurtsen W. Crown and restoration margins. Dtsch Zahnarztl Z 1990; 45: 380-386 5 Kosyfaki P, del Pilar Pinilla Martin M, Strub JR. Relationship between crowns and the periodontium: a literature update. Quintessence Int 2010; 41: 109-126 6 Morse DE, Holm-Pedersen P, Holm-Pedersen J et al. Prosthetic crowns and other clinical risk indicators of caries among old-old Swedish adults: findings from the KEOHS Project. Kungsholmen Elders Oral Health Study. Gerodontology 2002; 19: 73-79 7 Reitemeier B, Hänsel K, Walter MH et al. Effect of posterior crown margin placement on gingival health. J Prosthet Dent 2002; 87: 167-172 8 Carrotte PV, Winstanley RB, Green JR. A study of the quality of impressions for anterior crowns received at a commercial laboratory. Br Dent J 1993; 174: 235-240 9 Eames WB, Wallace SW, Suway NB et al. Accuracy and dimensional stability of elastomeric impression materials. J Prosthet Dent 1979; 42: 159-162 10 Hamalian TA, Nasr E, Chidiac JJ. Impression materials in fixed prosthodontics: influence of choice on clinical procedure. J Prosthodont 2011; 20: 153-160 11 Rudolph H, Quaas S, Luthardt R. Precision of duplicate dies made with different impression making procedures. Dent Mater 2008; 25: e27-e28 12 Lee IK, DeLong R, Pintado MR et al. Evaluation of factors affecting the accuracy of impressions using quantitative surface analysis. Oper Dent 1995; 20: 246-252 13 Luthardt RG, Walter MH, Weber A et al. Clinical parameters influencing the accuracy of 1- and 2-stage impressions: a randomized controlled trial. Int J Prosthodont 2008; 21: 322-327 14 Noack T, Balkenhol M, Ferger P et al. Accuracy of different polyvinylsiloxanes. Dtsch Zahnarztl Z 2004; 59: 590-592 15 Siemer A, Balkenhol M, Trost M et al. Accuracy of one-step vs. two-step putty-wash impressions – a 3-D in-vitro evaluation. Dtsch Zahnarztl Z 2004; 59: 585-589 16 Wichmann M, Borchers L, Limmroth E. Measuring the accuracy of various elastomeric impression materials using a CNC coordinate measuring device (Part 1). Dtsch Zahnarztl Z 1990; 45: 499-502 17 Rudolph H, Graf MR, Kuhn K et al. Performance of dental impression materials: Benchmarking of materials and techniques by three-dimensional analysis. Dent Mater J 2015; 34: 572-584 18 Rubel BS. Impression materials: a comparative review of impression materials most commonly used in restorative dentistry. Dent Clin North Am 2007; 51: 629-642 vi 19 Stober T, Johnson GH, Schmitter M. Accuracy of the newly formulated vinyl siloxanether elastomeric impression material. J Prosthet Dent 2010; 103: 228-239 20 Bader F, Setz J. Wettability and accuracy of reproduction of impression materials. Dtsch Zahnarztl Z 1991; 46: 346-348 21 Blatz MB. Impression techniques and their relation to material properties. Pract Proced Aesthet Dent 2003; 15: 512 22 Brown D. Materials for impressions – 2003. Dent Update 2004; 31: 40-45 23 Habib ANA, Shehata MT. The effect of the type and technique used for impression making on the accuracy of elastomeric impression materials. Egypt Dent J 1995; 41: 1409-1416 24 Lu H, Nguyen B, Powers JM. Mechanical properties of three hydrophilic addition silicone and polyether elastomeric impression materials. J Prosthet Dent 2004; 92: 151-154 25 Luthardt RG, Koch R, Rudolph H et al. Qualitative computer aided evaluation of dental impressions in vivo. Dent Mater 2006; 22: 69-76 26 Mandikos MN. Polyvinyl siloxane impression materials: an update on clinical use. Aust Dent J 1998; 43: 428-434 27 Stewardson DA. Trends in indirect dentistry: 5. Impression materials and techniques. Dent Update 2005; 32: 374-376 379–380, 382–384 28 Thongthammachat S, Moore BK, Barco 2nd MT et al. Dimensional accuracy of dental casts: influence of tray material, impression material, and time. J Prosthodont 2002; 11: 98-108 29 Wöstmann B, Höing M, Ferger P. Vergleich von hand- und maschinengemischten Abformmassen (Pentamix-System). Dtsch Zahnärztl Z 1998; 53: 753-756 30 Rudolph H, Quaas S, Haim M et al. Randomized controlled clinical trial on the three-dimensional accuracy of fast-set impression materials. Clin Oral Investig 2013; 17: 1397-1406 31 Bennani V, Schwass D, Chandler N. Gingival retraction techniques for implants versus teeth: current status. J Am Dent Assoc 2008; 139: 1354-1363 32 Baharav H, Kupershmidt I, Laufer BZ et al. The effect of sulcular width on the linear accuracy of impression materials in the presence of an undercut. Int J Prosthodont 2004; 17: 585-589 33 Nemetz EH, Seibly W. The use of chemical agents in gingival retraction. Gen Dent 1990; 38: 104-108 34 Donovan TE, Gandara BK, Nemetz H. Review and survey of medicaments used with gingival retraction cords. J Prosthet Dent 1985; 53: 525-531 35 Goldberg PV, Higginbottom FL, Wilson TG. Periodontal considerations in restorative and implant therapy. Periodontol 2000; 2001: 100-109 36 Wadhwani CP, Johnson GH, Lepe X et al. Accuracy of newly formulated fast-setting elastomeric impression materials. J Prosthet Dent 2005; 93: 530-539 37 Haim M, Luthardt RG, Rudolph H et al. Randomized controlled clinical study on the accuracy of two-stage putty-and-wash impression materials. Int J Prosthodont 2009; 22: 296-302 38 Luthardt RG, Walter MH, Quaas S et al. Comparison of the three-dimensional correctness of impression techniques: a randomized controlled trial. Quintessence Int 2010; 41: 845-853 39 Rudolph H, Quaas S, Haim M et al. Randomized controlled clinical trial on the three-dimensional accuracy of fast-set impression materials. Clin Oral Investig 2013; 17: 1397-1406 40 Rudolph H, Röhl A, Walter MH et al. Performance of fast-setting impression materials in the reproduction of subgingival tooth surfaces without soft tissue retraction. Int J Prosthodont 2014; 27: 366-375 41 Quaas S, Loos R, Rudolph H et al. Randomized controlled trial comparing direct intraoral digitization and extraoral digitization after impression taking. Int J Prosthodont 2015; 28: 30-32 42 Kamegawa M, Nakamura M, Fukui Y et al. Direct 3-D morphological measurements of silicone rubber impression using micro-focus X-ray CT. Dent Mater J 2010; 29: 68-74 43 Luthardt RG. Randomized controlled trial of impression techniques – accuracy of the three-dimensional reproduction of the relation of prepared tooth to adjacent teeth. Dtsch Zahnarztl Z 2003; 58: 337-342 44 Schaefer O, Schmidt M, Goebel R et al. Qualitative and quantitative three-dimensional accuracy of a single tooth captured by elastomeric impression materials: an in vitro study. J Prosthet Dent 2012; 108: 165-172 45 Shah S, Sundaram G, Bartlett D et al. The use of a 3D laser scanner using superimpositional software to assess the accuracy of impression techniques. J Dent 2004; 32: 653-658 46 Sjogren AP, Lindgren JE, Huggare JA. Orthodontic study cast analysis – reproducibility of recordings and agreement between conventional and 3D virtual measurements. J Digit Imaging 2010; 23: 482-492 47 Stimmelmayr M, Erdelt K, Güth JF et al. Evaluation of impression accuracy for a four-implant mandibular model – a digital approach. Clin Oral Investig 2012; 16: 1137-1142 48 Brosky ME, Pesun IJ, Lowder PD et al. Laser digitization of casts to determine the effect of tray selection and cast formation technique on accuracy. J Prosthet Dent 2002; 87: 204-209 49 Petrie CS, Walker MP, Oʼmahony AM et al. Dimensional accuracy and surface detail reproduction of two hydrophilic vinyl polysiloxane impression materials tested under dry, moist, and wet conditions. J Prosthet Dent 2003; 90: 365-372 50 Stimmelmayr M, Güth JF, Erdelt K et al. Digital evaluation of the reproducibility of implant scanbody fit-an in vitro study. Clin Oral Investig 2012; 16: 851-856 51 Al-Bakri IA, Hussey D, Al-Omari WM. The dimensional accuracy of four impression techniques with the use of addition silicone impression materials. J Clin Dent 2007; 18: 29-33 52 Balkenhol M, Ferger P, Wostmann B. Dimensional accuracy of 2-stage putty-wash impressions: influence of impression trays and viscosity. Int J Prosthodont 2007; 20: 573-575 53 Fenske C. The influence of five impression techniques on the dimensional accuracy of master models. Braz Dent J 2000; 11: 19-27 54 Franco EB, da Cunha LF, Herrera FS et al. Accuracy of Single-Step versus 2-Step Double-Mix Impression Technique. ISRN Dent 2011; 2011: 341546 55 Gomez-Polo M, Celemin A, del Rio J et al. Influence of technique and pouring time on dimensional stability of polyvinyl siloxane and polyether impressions. Int J Prosthodont 2012; 25: 353-356 56 Hassan AK. Dimensional accuracy of 3 silicone dental impression materials. East Mediterr Health J 2006; 12: 632-636 57 Hoyos A, Soderholm KJ. Influence of tray rigidity and impression technique on accuracy of polyvinyl siloxane impressions. Int J Prosthodont 2011; 24: 49-54 58 Levartovsky S, Lew G, Brosh T et al. Dimensional stability of polyvinyl siloxane impression material reproducing the sulcular area. Dent Mater J 2013; 32: 25-31 59 Nissan J, Laufer BZ, Brosh T et al. Accuracy of three polyvinyl siloxane putty-wash impression techniques. J Prosthet Dent 2000; 83: 161-165 60 Nissan J, Gross M, Shifman A et al. Effect of wash bulk on the accuracy of polyvinyl siloxane putty-wash impressions. J Oral Rehabil 2002; 29: 357-361 61 Omar R, Abdullah MA, Sherfudhin H. Influence on dimensional accuracy of volume of wash material introduced into pre-spaced putty/wash impressions. Eur J Prosthodont Restor Dent 2003; 11: 149-155 62 Pereira JR, Murata KY, Valle AL et al. Linear dimensional changes in plaster die models using different elastomeric materials. Braz Oral Res 2010; 24: 336-341 63 Piwowarczyk A, Ottl P, Büchler A et al. In vitro study on the dimensional accuracy of selected materials for monophase elastic impression making. Int J Prosthodont 2002; 15: 168-174 64 Shiozawa M, Takahashi H, Finger WJ et al. Effects of the space for wash materials on sulcus depth reproduction with addition-curing silicone using two-step putty-wash technique. Dent Mater J 2013; 32: 150-155 65 Tredwin CJ, Nesbit M, Butta R et al. Effect of a laboratory surfactant on compatibility of type IV dental stones with addition-cured silicone impression materials. Eur J Prosthodont Restor Dent 2008; 16: 73-76 66 Chandran DT, Jagger DC, Jagger RG et al. Two- and three-dimensional accuracy of dental impression materials: effects of storage time and moisture contamination. Biomed Mater Eng 2010; 20: 243-249 67 Cayouette MJ, Burgess JO, Jones jr RE et al. Three-dimensional analysis of dual-arch impression trays. Quintessence Int 2003; 34: 189-198 68 Kwon JH, Son YH, Han CH et al. Accuracy of implant impressions without impression copings: a three-dimensional analysis. J Prosthet Dent 2011; 105: 367-373 69 Papaspyridakos P, Benic GI, Hogsett VL et al. Accuracy of implant casts generated with splinted and non-splinted impression techniques for edentulous patients: an optical scanning study. Clin Oral Implants Res 2012; 23: 676-681 70 Persson AS, Odén A, Andersson M et al. Digitization of simulated clinical dental impressions: virtual three-dimensional analysis of exactness. Dent Mater 2009; 25: 929-936 71 Kuhn K, Ostertag S, Ostertag M et al. Comparison of an analog and digital quantitative and qualitative analysis for the fit of dental copings. Comput Biol Med 2015; 57: 32-41 72 Quaas S, Rudolph H, Luthardt RG. Direct mechanical data acquisition of dental impressions for the manufacturing of CAD/CAM restorations. J Dent 2007; 35: 903-908 73 Rudolph H, Salmen H, Moldan M et al. Accuracy of intraoral and extraoral digital data acquisition for dental restorations. J Appl Oral Sci 2016; 24: 85-94 74 Ender A, Mehl A. Accuracy of complete-arch dental impressions: a new method of measuring trueness and precision. J Prosthet Dent 2013; 109: 121-128 75 Cook KT, Fasbinder DJ. Accuracy of CAD/CAM crown fit with infrared and LED cameras. Int J Comput Dent 2012; 15: 315-326 76 Patzelt SB, Vonau S, Stampf S et al. Assessing the feasibility and accuracy of digitizing edentulous jaws. J Am Dent Assoc 2013; 144: 914-920 77 Papaspyridakos P, Gallucci GO, Chen CJ et al. Digital versus conventional implant impressions for edentulous patients: accuracy outcomes. Clin Oral Implants Res 2016; 27: 465-472 78 Chen H, Wang H, Lv P et al. Quantitative evaluation of tissue surface adaption of CAD-designed and 3D printed wax pattern of maxillary complete denture. Biomed Res Int 2015; 2015: 453968 79 Kattadiyil MT, Mursic Z, AlRumaih H et al. Intraoral scanning of hard and soft tissues for partial removable dental prosthesis fabrication. J Prosthet Dent 2014; 112: 444-448 80 Matsuda T, Goto T, Yagi K et al. Part-digitizing system of impression and interocclusal record for complete denture fabrication. J Prosthodont 2015;