Thorac Cardiovasc Surg 2024; 72(01): 077-083
DOI: 10.1055/s-0043-1768967
Original Thoracic

Sternal Pin Used to Close Sternum in Infants after Cardiac Surgery

Wen-Peng Xie
1   Department of Cardiac Surgery, Fujian Children's Hospital (Fujian Branch of Shanghai Children's Medical Center), College of Clinical Medicine for Obstetrics and Gynecology and Pediatrics, Fujian Medical University, Fuzhou, China
,
Xiu-Hua Chen
1   Department of Cardiac Surgery, Fujian Children's Hospital (Fujian Branch of Shanghai Children's Medical Center), College of Clinical Medicine for Obstetrics and Gynecology and Pediatrics, Fujian Medical University, Fuzhou, China
,
Si-Jia Zhou
1   Department of Cardiac Surgery, Fujian Children's Hospital (Fujian Branch of Shanghai Children's Medical Center), College of Clinical Medicine for Obstetrics and Gynecology and Pediatrics, Fujian Medical University, Fuzhou, China
,
1   Department of Cardiac Surgery, Fujian Children's Hospital (Fujian Branch of Shanghai Children's Medical Center), College of Clinical Medicine for Obstetrics and Gynecology and Pediatrics, Fujian Medical University, Fuzhou, China
,
Hua Cao
1   Department of Cardiac Surgery, Fujian Children's Hospital (Fujian Branch of Shanghai Children's Medical Center), College of Clinical Medicine for Obstetrics and Gynecology and Pediatrics, Fujian Medical University, Fuzhou, China
› Author Affiliations
Zoom Image

Abstract

Objective A retrospective study was conducted to explore the efficacy of bioabsorbable poly-L-lactic acid sternal pins in sternal closure in infants after cardiac surgery.

Methods A total of 170 infantile patients who underwent cardiac surgery were divided into the steel wire group (group A), the PDS cord group (group B), and the steel wire + sternal pin group (group C). The occurrence of the thoracic deformity was evaluated by vertebral index (VI), frontosagittal index (FSI), and Haller index (HI) values; the stability of the sternum was evaluated by detecting sternal dehiscence and displacement.

Results By comparing the absolute values of the differences in VI, FSI, and HI in the three groups, it was found that the difference values of VI and HI in group C were significantly lower than those in group B (p = 0.028 and 0.005). For the highest deformation index, the deformation rate of infants in group C before discharge and during the 1-year follow-up was lower than that in group A and group B (p = 0.009 and 0.002, respectively). The incidence of sternal displacement in group C was also significantly lower than that in groups A and B (p = 0.009 and 0.009). During the 1-year follow-up, there was no sternal dehiscence, and the sternum healed completely in the three groups.

Conclusion The use of “steel wire + sternal pin” for sternal closure in infants after cardiac surgery can reduce the occurrence of sternal deformity, reduce anterior and posterior displacement of the sternum, and improve sternal stability.

Data Availability Statement

The data that support the findings of this study are available on request from the corresponding author. The data are not publicly available due to privacy or ethical restrictions.


Authors' Contribution

W.-P.X. and H.C. designed the study, performed the statistical analysis, participated in the operation, and drafted the manuscript. X.-H.C, S.-J.Z. and Q.C. collected the clinical data. All authors read and approved the final manuscript.




Publication History

Received: 21 November 2022

Accepted: 11 April 2023

Article published online:
25 May 2023

© 2023. Thieme. All rights reserved.

Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany