Summary
Aim: In a prospective study we measured the velocity ranges of the Doppler Velocity Histogram (DVH) of the hepatic venous system at two levels (- 3 dB and - 6 dB) below the maximum power level of the Doppler wave in order to investigate if that allows a higher selectivity between the Doppler tracings in hepatic veins of patients with liver cirrhosis and healthy subjects. Methods: The DVH was measured in 23 healthy subjects and 31 patients with liver cirrhosis of different etiologies at power levels of - 3 and - 6dB in the right and middle hepatic vein after an overnight fast. The DVH measurements were performed at the maximum of phase I of the hepatic venous flow in which we assessed the Peak-, Mode-, Mean-Value, and the velocity range (bandwidth). Results: At both power levels the bandwidth (BW) of the DVH in the right and middle hepatic vein was significantly higher in cirrhotics than in healthy subjects (- 3 dB: RHV: p = 0.048, MHV: p = 0.006; - 6 dB: RHV and MHV: p < 0.0005). The selectivity between healthy subjects and cirrhotics is higher at the - 6 dB level than at the - 3 dB level. Conclusion: The DVH-measurement is a useful additional device in early sonographic detection of cirrhotic liver parenchyma changes. DVH-velocity range measurements at a level of - 6 dB below the maximum power level reveal a better selectivity between healthy subjects and cirrhotic patients than measurements at the -3dB level. It is recommendable to perform velocity range measurements at different power levels within a single frozen image.
Die Rolle der Doppler-Geschwindigkeits-Histogramme der hepatischen Venen bei der Früherkennung zirrhotischer Veränderungen des Leberparenchyms
Ziel: In einer prospektiven Studie wurde das Duplexgeschwindigkeitshistogramm (DGH) der Lebervenen bei zwei verschiedenen Leistungsbereichen (- 3 dB und - 6 dB) unterhalb des Leistungsmaximums bestimmt und untersucht, ob durch die zusätzliche Verwendung des - 6 dB-Messbereichs eine höhere Trennschärfe zwischen gesundem Leberparenchym und Leberzirrhose zu erreichen ist. Material und Methode: Es wurde bei 23 Lebergesunden und 31 Patienten mit Leberzirrhose unterschiedlicher Ätiologie nach mindestens achtstündiger Nahrungskarenz das DGH bei den Leistungsbereichen von - 3 und - 6 dB an der rechten und mittleren Lebervene gemessen. Im DGH wurden im Maximum der Lebervenenflussphase I der Dopplerspektraldarstellung der Scheitelwert, Modalwert, der intensitätsgerichtete Mittelwert und die Bandbreite (BW) der Flussgeschwindigkeit bestimmt. Ergebnisse: In beiden Intensitätsbereichen (- 3 dB und - 6 dB) ist die BW des DGH in der rechten und mittleren Lebervene bei Patienten mit Leberzirrhose signifikant höher als bei Lebergesunden. Die Trennschärfe zwischen Gesunden und Zirrhotikern ist im - 6 dB-Intensitätsbereich höher als im - 3 dB-Bereich. Schlussfolgerung: Das DGH ist eine nützliche Erweiterung in der frühen sonographischen Diagnostik von zirrhotischen Leberparenchymumbauten. Bei der Bestimmung der Bandbreite im DGH bietet der - 6 dB-Messbereich im Vergleich zu - 3 dB eine höhere Trennschärfe zwischen Lebergesunden und Leberzirrhotikern. Bandbreitenbestimmungen sollten bei verschiedenen Leistungsbereichen innerhalb einer Messung ermöglicht werden.
Key words:
Doppler sonography - Velocity histogram - Liver cirrhosis - Hepatic veins - Bandwidth - Velocity range
Schlüsselwörter:
Duplex-Sonographie - Geschwindigkeitshistogramm - Leberzirrhose - Lebervenen - Bandbreite
References
-
1
Pennestri F, Loperfido F, Salvatori M P, Mongiardo R, Ferrazza A, Guccione P, Manzole U.
Assessment of Tricuspid Regurgitation by Pulsed Doppler Ultrasonography of the Hepatic Veins.
Am J Cardiol.
1984;
54
363-368
-
2
Yoshida K, Qoshikawa J, Yanagihara K, Kato H, Okumachi F, Koizumi K, Shiratori K, Asaka T.
Doppler hepatic vein flow mimicking jugular phlebograms: Its clinical application.
J Cardiol.
1984;
14
69-71
-
3
Abu-Yousef M M.
Normal and Respiratory Variations of the Hepatic and Portal Venous Duplex Doppler Waveforms with Simultaneous Electrocardiographic Correlation.
J Ultrasound Med.
1992;
11
263-268
-
4
Reynolds T, Appleton C P.
Doppler Flow Velocity Patterns of the Superior Vena Cava, Inferior Vena Cava, Hepatic Vein, Coronary Sinus, and Atrial Septal Defect: A Guide for the Echocardiographer.
J Am Echocardiogr.
1991;
4
503-512
-
5
Reynolds T, Szymanski K, Langenfeld K, Appleton C P.
Visualization of the Hepatic Veins: New Approaches for the Echocardiographer.
J Am Soc Echo.
1991;
4
93-96
-
6
Bolondi L, Li Bassi S, Gaiani S, Zironi G, Benzi G, Santi V, Barbara L.
Liver Cirrhosis: Changes of Doppler Waveform of Hepatic Veins.
Radiology.
1991;
178
513-516
-
7
Teichgräber U KM, Gebel M, Hecker H, Benter T, Manns M P.
Bedeutung des Duplex-Geschwindigkeitshistogramms zur Diagnose der Leberzirrhose.
RöFo.
1996;
509
59-63
-
8
Teichgräber U K, Gebel M, Benter T, Manns M P.
Duplex ultrasound characterization of hepatic vein blood flow in healthy probands.
Ultraschall Med.
1997;
18
267-271
-
9
Dietrich C F, Lee J H, Gottschalk R, Herrmann G, Sarrazin C, Caspary W F, Zeuzem S.
Hepatic and portal vein flow pattern in correlation with intrahepatic fat deposition and liver histology in patients with chronic hepatitis C.
Am J Roentgenol.
1998;
171
437-443
-
10
Yasuhara K, Kimuara K, Nakamura H, Iwadare M, Ohto M, Matsuzaki O.
Doppler Velocity Histogram Analysis of Hepatocellular Carcinoma.
Clin Ultrasound.
1995;
23
225-231
-
11
Cobet U, Pfundner P, Walke M, Schultz M, Schrödter I.
Determination of cell interaction forces in suspensions with ultrasonic scattering.
IEEE Ultrasonics Symposium.
1995;
2
1231-1236
Prof. Dr. med. Michael Gebel
Department of Gastroenterology and HepatologyMedizinische Hochschule Hannover
Carl-Neuberg-Straße 130625 Hannover