Subscribe to RSS
DOI: 10.1055/s-2002-30628
© Georg Thieme Verlag Stuttgart · New York
Operative Treatment of Lateral Malleolar Fractures by Intramedullary Screw Fixation
A Retrospective StudyPublication History
Publication Date:
17 May 2002 (online)
Abstract
Objectives: The purpose of this study is to evaluate an alternative technique of osteosynthesis of lateral malleolar fractures by intramedullary fixation.
Material and Methods: We retrospectively reviewed forty-three patients with Weber B and C type displaced lateral malleolar fractures, treated with an intramedullary, fully threaded and self-tapping screw, after closed or open reduction. The patients were examined, clinically and radiographically, after a mean follow-up period of 4 years and 1 month.
Results: The radiographic results were good (12 %) and excellent (84 %) in 96 % of patients. Functionally, there were good (21 %) and excellent (65 %) results in 85 % of patients.
No deep wound infections occurred. There were two superficial infections. Four patients had reflex sympathetic dystrophy syndrome. Screws had to be removed in 25 % of patients because of fibular malleolus pressure pain. Only two patients of this group (5 % in total) had severe complaints related to the intramedullary screw.
Conclusion: This technique requires less extensive soft tissue dissection, gives a reduction comparable to other methods, and leaves the possibility for fracture compression. In addition, there are less hardware complaints.
Although improvements of the screw are at hand, we believe that this technique is already a valuable alternative to other methods.
Zusammenfassung
Ziel: In der vorliegenden Studie wird eine alternative Technik für die Osteosynthese lateraler Malleolarfrakturen durch Markraumverschraubung evaluiert.
Material und Methoden: 43 Patienten mit Weber Typ B und C dislozierten lateralen Malleolarfrakturen, versorgt mit einer intramedullären, völlig mit Gewinde versehenen und selbstschneidenden Schraube nach geschlossener oder offener Reposition, wurden klinisch und röntgenologisch nach einer durchschnittlichen Nachbeobachtung von 4 Jahren und 1 Monat untersucht.
Ergebnisse: Die Röntgenbefunde waren gut (12 %) und ausgezeichnet (84 %) bei 96 % der Patienten. Die funktionellen Ergebnisse waren gut (21 %) und ausgezeichnet (65 %) bei 85 % der Patienten. Es gab keine tiefen Wundinfektionen. Zwei oberflächliche Infektionen wurden beobachtet. Bei 4 Patienten entwickelte sich eine Sudecksche Dystrophie.
Bei 25 % der Patienten war wegen Drückschmerzen am distalen lateralen Malleolus Entfernung der Schrauben notwendig. Nur 2 Patienten in dieser Gruppe (insgesamt 5 %) hatten ernsthafte, duch die intramedulläre Schraube verursachte Beschwerden.
Schlussfolgerung: Diese Technik erfordert eine weniger ausgedehnte Weichteildissektion, ermöglicht eine mit anderer Methoden vergleichbare Reposition und ebenfalls eine Frakturkompression. Außerdem gibt es weniger durch das Material verursachte Beschwerden.
Obwohl Verbesserungen an der Schraube geplant sind, sind wir der Meinung, dass diese Technik schon eine wertvolle Alternative für andere Methoden ist.
Key words
Ankle fracture - Ankle fracture fixation - Unimalleolar fracture osteosynthesis - Unimalleolar fracture screw fixation
Schlüsselwörter
Sprunggelenksfraktur - Sprunggelenksfrakturfixierung - Laterale Malleolarfrakturosteosynthese - Laterale Malleolarfrakturverschraubung
References
- 1 Bankston A B, Anderson L D, Nimityongskul P. Intramedullary screw fixation of lateral malleolus fractures. Foot Ankle Int. 1994; 15 599-607
- 2 Beris A E, Kabbani K T, Mitsionis G, Soucacos P K, Soucacos P N. Surgical treatment of malleolar fractures: a review of 144 patients. Clin Orthop. 1997; 341 90-98
- 3 De Souza L J, Gustilo R B, Meyer T J. Results of operative treatment of displaced external rotation-abduction fractures of the ankle. J Bone Joint Surg [Am]. 1985; 67 1066-1074
- 4 Grady J F, Moore C J, O’Connor K J, La Montagne D. The use of a transsyndesmotic bolt in the treatment of tibiofibular diastasis. J Foot Ankle Surg. 1995; 34 571-576
- 5 McLennan J G, Ungersma J A. A new approach to the treatment of ankle fractures: the Inyo nail. Clin Orthop. 1986; 213 125-136
-
6 Müller M E, Allgöwer M, Schneider R. et al .Manual of internal fixation: Techniques recommended by the AO group. Springer, Berlin 1992
- 7 Olerud C, Molander H. Bi- and trimalleolar fractures operated with nonrigid internal fixation. Clin Orthop. 1986; 206 253-260
- 8 Ramsey P L, Hamilton W. Changes in tibiotalar area of contact caused by lateral talar shift. J Bone Joint Surg [Am]. 1976; 58 356-357
- 9 Ray T D, Nimityongskul P, Anderson L D. Percutaneous intramedullary fixation of lateral malleolus fractures: technique and report of early results. J Trauma. 1994; 36 669-675
- 10 Schaffer J J, Manoli A. The antiglide plate for distal fibular fixation. J Bone Joint Surg [Am]. 1987; 69 596-604
-
11 Verbrugge J. A propos de l’ instrumentation en chirurgie des fractures: une nouvelle boîte de materiel. Bruxelles - Médical 1933; 25: 1
- 12 Wilson F J, Skilbred L A. Long-term results in the treatment of displaced bimalleolar fractures. J Bone Joint Surg [Am]. 1966; 48 1065-1078
- 13 Yablon I G, Heller F G, Shouse L. The key role of the lateral malleolus in displaced fractures of the ankle. J Bone Joint Surg [Am]. 1977; 59 169-173
René Verdonk M.D., Ph.D.
UZ Gent, poli 5
De Pintelaan 185
9000 Gent
Belgium
Phone: +32-9-240 22 64
Fax: +32-9-240 49 75
Email: rene.verdonk@rug.ac.be