Circulating Microemboli after Composite Replacement or Valve-sparing Aortic Root Surgery
Publication History
July 22, 2001
Publication Date:
21 June 2002 (online)
Abstract
Background: The purpose of this study was to determine whether microembolic signals (MES) occur after valve-sparing operations on the aortic root. One of the advantages of these procedures relates to the freedom of macroemboli without anticoagulation. Whether this holds true for circulating microemboli has not yet been verified. Methods: For comparison, 8 male patients (mean age: 51.8 ± 12.8 years) were investigated 20.5 ± 8.4 months after implantation of a mechanical composite graft (group I) and 9 female and 7 male patients (mean age 55.0 ± 13.4 years) 23.5 ± 20.0 months after valve-sparing replacement of the aortic root (group II). The middle cerebral artery was insonated for 2 periods of 30 min, breathing room air or O2 at 9 l/min. Results: Breathing room air, the amount of MES was considerably smaller in group II (0.94 ± 1.95 vs. 56.1 ± 58.9 per 30 min, p = 0.006). The difference was less pronounced (0.5 ± 1.3 vs. 28.9 ± 42.6 per 30 min, p = 0.009) breathing oxygen. Breathing oxygen reduced MES significantly in group I (p < 0.05) but not in group II (p > 0.05). Conclusions: Aortic valve-sparing operations induce MES at a significantly lower rate than composite aortic valve replacement using a mechanical valve.
Key words
Aorta - Valves - Aneurysm - Microembolism
References
- 1 Kouchoukos N T, Wareing T H, Murphy S F, Perillo J B. Sixteen-year experience with aortic root replacement: results of 172 operations. Ann Surg. 1991; 214 308-320
- 2 Yacoub M, Fayan A, Stassano P, Radley-Smith R. Results of valve conserving operations for aortic regurgitation. Circulation. 1983; 68 (III) 321
- 3 Sarsam M A, Yacoub M. Remodeling of the aortic valve anulus. J Thorac Cardiovasc Surg. 1993; 105 435-438
- 4 David T E, Feindel C M. An aortic valve-sparing operation for patients with aortic incompetence and aneurysm of the ascending aorta. J Thorac Cardiovasc Surg. 1992; 103 617-622
- 5 Leyh R G, Schmidtke C, Sievers H H, Yacoub M H. Opening and closing characteristics of the aortic valve after different types of valve-preserving surgery. Circulation. 1999; 100 2153-2160
- 6 Babikian V L, Hyde C, Pochay V, Winter M R. Clinical correlates of high-intensity transient signals detected on transcranial Doppler sonography in patients with cerebrovascular disease. Stroke. 1994; 25 1570-1573
- 7 Georgiadis D, Grosset D G, Kelman A, Fainchey A, Lees K R. Prevalence and characteristics of intracranial microemboli signals in patients with different types of prosthetic cardiac valves. Stroke. 1994; 25 585-592
- 8 Rams J J, Davis A D, Lolley D M, Berger M P, Spencer M. Detection of microemboli in patients with artificial heart valves using transcranial Doppler monitoring: preliminary observations. J Heart Valve Dis. 1993; 2 37 41
- 9 van Zuilen E V, Moll F L, Vermeulen F E, van Gijn J, Ackerstaff R G. Detection of cerebral microemboli by means of transcranial Doppler monitoring before and after carotid endarterectomy. Stroke. 1995; 26 210-213
- 10 Siebler M, Sitzer M, Steinmetz H. Detection of intracranial emboli in patients with symptomatic extracranial carotid artery disease. Stroke. 1992; 23 1652-1654
- 11 Braekken S K, Russell D, Brucher R, Svenevig J. Incicence and frequency of cerebral embolic signals in patients with prosthetic cardiac valves. Stroke. 1995; 26 1225-1230
- 12 Georgiadis D, Mallinson A, Grosset D G, Lees K R. Coagulation activity and emboli counts in patients with prosthetic cardiac valves. Stroke. 1994; 25 1211-1214
- 13 Shu M CS, Gross J M, Johnson K M. Can cavitation bubbles generated by mechanical heart valves be detected by transcranial Doppler?. J Heart Valve Dis<. 1995; 4 542-552
- 14 Kaps M, Hansen J, Weiher M, Tiffert K, Kayser I, Droste D W. Clinically silent microemboli in patients with artificial prosthetic aortic valves are predominantly gaseous and not solid. Stroke. 1997; 28 322-326
- 15 Georgiadis D, Baumgartner R W, Karatschai R, Lindner A, Zerkowski H R. Further evidence of gaseous embolic material in patients with artificial heart valves. J Thorac Cardiovasc Surg. 1998; 115 808-810
- 16 Droste D W, Markus H S, Brown N M. The effect of different settings of ultrasound pulse amplitude, gain and sample volume on the appearance of emboli studied in a transcranial Doppler model. Cerebrovasc Dis. 1994; 4 152-154
- 17 Marascuilo L A, McSweeney M. Nonparametric and distribution-free methods for the social sciences. Monterey, California; Brooks/ Cole Publishing Company 1997: 333-334
- 18 Nötzold A, Droste D W, Hagedorn G. et al . Circulating microemboli in patients after aortic valve replacement with pulmonary autografts and mechanical valve prostheses. Circulation. 1997; 96 1843-1846
- 19 Garrison L A, Lamson T C, Deutsch S, Geselowitz D B, Gaumond J M, Tarbell J M. An in-vitro investigation of prosthetic heart valve cavitation in blood. J Heart Valve Dis. 1994; 3 S8-S24
- 20 Yacoub M H, Gehle P, Chandrasekaran V, Birks E J. Child A, Radley-Smith R. Late results of a valve preserving operation in patients with aneurysms of the ascending aorta and root. J Thorac Cardiovasc Surg. 1998; 115 (I) 1080-1090
Prof. Dr. Hans Hinrichs Sievers
Klinik für Herzchirurgie Medizinische Universität zu Lübeck
Ratzeburger Allee 160
23538 Lübeck
Germany
Phone: +49 (451) 500-2108
Fax: +49 (451) 500-2051
Email: noetzold@medinf.mu-luebeck.de