Subscribe to RSS
DOI: 10.1055/s-2004-815849
© Georg Thieme Verlag KG Stuttgart · New York
Modification of the Wingate Anaerobic Power Test for Rowing: Optimization of the Resistance Setting
Publication History
Accepted after revision: September 20, 2003
Publication Date:
18 May 2004 (online)
Abstract
The purpose of the study was to determine the resistance factor that would elicit the highest peak 5 s and mean 30 s power output (PO) during a maximal 30 s anaerobic power test on a rowing ergometer. Thirty-one rowers (17 male and 14 female) were recruited based on the light-weight (LW) (6 male; age 23 ± 6 yrs and 6 female; age 19 ± 2 yrs) and heavy-weight (HW) (11 male; age 24 ± 4 yrs and 8 female; age 27 ± 8 yrs) rowing categories. Each group completed 5 randomized series of maximal 30 s sprints equivalent to the following forces: 58.9, 63.8, 68.7, 73.7 and 78.6 N for LW males; 83.5, 88.4, 93.4, 98.2 and 103.1 N for HW males; 29.4, 34.3, 39.2, 44.1 and 49.1 N for LW females; and 44.1, 49.1, 54.0, 58.6 and 63.8 N for HW females. The tests were performed on a Gjessing rowing ergometer modified to accommodate greater resistance settings and computer linked to obtain the necessary data. The peak 5 s and mean 30 s PO (W) were determined for each test. A relative load factor (RLF) for determining the amount of resistance to be applied was calculated based on body mass (BM). The RLF settings that elicited the highest peak 5 s PO were 0.109 and 0.102 kg · kg-1 BM for LW and HW male rowers and 0.111 kg · kg-1 BM and 0.076 kg · kg-1 BM for LW and HW female rowers, respectively. The RLF settings for eliciting the highest mean 30 s PO were 0.102 and 0.095 kg · kg-1 BM for LW and HW male rowers and 0.103 kg · kg-1 BM and 0.068 kg · kg-1 BM for LW and HW female rowers, respectively. A 30 second anaerobic test was also performed on a Concept II rowing machine for comparison and it was found to elicit a significantly lower peak 5 s but not 30 s PO in both male and female rowers. Our findings provide RLFs for assessing anaerobic power using a 30 s test in male and female rowers. As well, peak 5 s but not mean 30 s PO is underestimated using the Concept II rowing machine.
Key words
Force - power output - fatigue - sprint - ergometry
References
- 1 Bar-Or O. The Wingate anaerobic test. An update on methodology, reliability and validity. Sports Med. 1987; 4 381-394
- 2 Bell G J, Petersen S R, Quinney H A, Wenger H A. The effect of velocity-specific strength training on peak torque and anaerobic rowing power. J Sports Sci. 1989; 7 205-214
- 3 Coggan A R, Costill D L. Biological and technological variability of three anaerobic ergometer tests. Int J Sports Med. 1984; 5 142-145
- 4 Dotan R, Bar-Or O. Load optimalization for the Wingate anaerobic test. Eur J Appl Physiol. 1983; 51 409-417
- 5 Evans J A, Quinney H A. Determination of resistance settings for anaerobic power testing. Can J Appl Spt Sci. 1981; 6 53-56
- 6 Gillies E M, Bell G J. The relationship of physical and physiological parameters to 2000 m simulated rowing performance. Sports Med Training Rehab. 2000; 9 277-288
- 7 Inbar O, Bar-Or O, Skinner J S. The Wingate Anaerobic Test. Champaign, IL; Human Kinetics 1996
- 8 Koutedakis Y, Sharp N C. A modified Wingate test for measuring anaerobic work of the upper body in junior rowers. Brit J Sports Med. 1986; 20 153-156
- 9 Manning J M, Dooly-Manning C, Perrin D H. Factor analysis of various anaerobic power tests. J Sports Med Phys Fitness. 1988; 28 138-144
- 10 Patton J F, Murphy M M, Frederick F A. Maximal power outputs during the Wingate anaerobic test. Int J Sports Med. 1985; 6 82-85
- 11 Pripstein L P, Rhodes E C, McKenzie D C. Aerobic and anaerobic energy during a 2-km race simulation in female rowers. Eur J Appl Physiol. 1999; 79 491-494
- 12 Reilly T, Bayley K. The relation between short-term power output and sprint performance of young female swimmers. J Human Movement Studies. 1988; 14 19-29
- 13 Secher N H. Physiological and biomechanical aspects of rowing. Sports Med. 1993; 15 24-42
- 14 Tharp G D, Newhouse R K, Uffelman L, Thorland W G, Johnson G O. Comparison of sprint and running times with performance on the Wingate anaerobic test. Res Q. 1985; 56 73-76
- 15 Vandewalle H, Peres G, Monod H. Standard anaerobic exercise tests. Sports Med. 1987; 4 268-289
Ph.D. Gordon Bell
Faculty of Physical Education and Recreation · University of Alberta
E424 Van Vliet Center
Edmonton, Alberta, T6G 2H9
Canada
Phone: + 7804922018
Fax: + 78 04 92 23 64
Email: Gordon.bell@ualberta.ca