Subscribe to RSS
DOI: 10.1055/s-2004-826038
Wireless Capsule Endoscopy for Evaluation of Phenotypic Expression of Small-Bowel Polyps in Patients with Peutz-Jeghers Syndrome and in Symptomatic First-Degree Relatives
†Dr. Pinho died in December 2002.Publication History
Submitted 7 March 2004
Accepted after Revision 2 August 2004
Publication Date:
01 December 2004 (online)
Background and Study Aims: Peutz-Jeghers syndrome (PJS) is an inherited gastrointestinal hamartomatous polyposis disorder. Small-bowel intussusception and bleeding are the most common complications, and malignancy may also occur. Survey of the gastrointestinal tract, particularly of the small bowel, is difficult and current recommendations for management syndrome are ambiguous. We evaluated the feasibility of capsule endoscopy for identifying phenotypic expression of small-bowel polyps in patients with full-blown PJS and a previous diagnosis of gastrointestinal polyposis, and in symptomatic kindred of PJS patients with no previous diagnosis of gastrointestinal polyposis.
Patients and Methods: Two groups were studied: group A consisted of 14 patients with gastrointestinal polyposis, eight of whom had undergone previous small-intestine surgery; group B consisted of six symptomatic first-degree relatives of PJS patients; these patients had previous negative gastrointestinal endoscopic examinations.
Results: Numerous polyps were detected in all patients in group A. Most polyps were sessile, but the larger polyps tended to be pedunculated. Polyp density was highest in the jejunum (greater than in the ileum and duodenum). Seven patients had at least one large polyp (> 11 mm) and five of these patients subsequently underwent enteroscopy, which revealed that capsule endoscopy had correctly identified all the patients with large polyps, but had missed 20 % of the total number of large polyps in these patients. No polyps were detected by capsule endoscopy in group B patients, despite the excellent visualization of the small intestine. In all patients, the capsules were expelled within 24 hours, without complications, and the procedure was well tolerated.
Conclusions: Capsule endoscopy is an effective and well-tolerated method for evaluating small-bowel pathology in patients with PJS.
References
- 1 Jenne D E, Reiman H, Nezu J. et al . Peutz-Jeghers syndrome is caused by mutations in a novel serine threonine kinase. Nat Genet. 1998; 18 38-43
- 2 Jishage K, Nezu J, Kawase Y. et al . Role of Lkb1, the causative gene of Peutz-Jeghers syndrome, in embryogenesis and polyposis. Proc Natl Acad Sci USA. 2002; 99 8903-8908
- 3 Wirzfiel D A, Petrelli N J, Rodrigues-Bigas M A. Hamartomatous polyposis syndromes: molecular genetics, neoplastic risk, and surveillance recommendations. Ann Surg Oncol. 2001; 8 319-327
- 4 McGarrity T J, Kulin H E, Zaino R J. Peutz-Jeghers syndrome. Am J Gastroenterol. 2000; 95 596-604
- 5 Tomlinson I P, Houlston R S. Peutz-Jeghers syndrome. J Med Genetics. 1997; 34 1007-1011
- 6 Hyer W. Polyposis syndromes. Gastrointest Endosc Clin N Am. 2001; 11 659-682, vi-vii
- 7 Giardello F M, Brensinger J D, Tersmette A C. et al . Very high risk of cancer in familial Peutz-Jeghers syndrome. Gastroenterology. 2000; 119 1447-1453
- 8 Boardman L A, Pittelkow M R, Couch F J. et al . Association of Peutz-Jeghers-like pigmentation with breast and gynaecologic carcinomas in women. Medicine (Baltimore). 2000; 79 293-298
- 9 Choi H S, Park Y J, Youk E G. et al . Clinical characteristics of Peutz-Jeghers syndrome in Korean polyposis patients. Int J Colorectal Dis. 2000; 15 35
- 10 Pennazio M, Rossini F P. Small bowel polyps in Peutz-Jeghers syndrome: management by combined push enteroscopy and intraoperative enteroscopy. Gastrointest Endosc. 2000; 51 304-308
- 11 Lin B C, Lien J M, Chen R J. et al . Combined endoscopic and surgical treatment for the polyposis of Peutz-Jeghers syndrome. Surg Endosc. 2000; 14 1185-1187
- 12 Costamagna G, Shah S K, Ricicioni M E. et al . A prospective trial comparing small bowel radiographs and video capsule endoscopy for suspected small bowel disease. Gastroenterology. 2002; 123 999-1005
- 13 Iddan G, Meron G, Glukhovsky A, Swain P. Wireless capsule endoscopy. Nature. 2000; 405 417
- 14 Ginsberg G G, Barkum A N, Bosco J J. et al . Status evaluation report on wireless endoscopy. ASGE Technology Assessment Committee. Gastrointest Endosc. 2002; 56 621-624
- 15 Herrerias J M, Caunedo A, Rodriguez-Telles M, Herrerias J M, Jr. Capsule endoscopy in patients with suspected Crohn’s disease and negative endoscopy. Endoscopy. 2003; 35 564-568
- 16 Mylonaki M, Fritscher-Ravens A, Swain P. Wireless capsule endoscopy: a comparison with push enteroscopy in patients with gastroscopy- and colonoscopy-negative gastrointestinal bleeding. Gut. 2003; 52 1122-1126
- 17 Saurin J C, Delvaux M, Gaudin J L. et al . Diagnostic value of endoscopic capsule in patients with obscure digestive bleeding: blinded comparison with video push-enteroscopy. Endoscopy. 2003; 35 576-584
- 18 Benz C, Jakobs R, Riemann J F. Do we need the overtube for push-enteroscopy?. Endoscopy. 2001; 33 659-661
- 19 Edwards D P, Khosraviani K, Stafferton R, Phillips R K. Long-term results of polyp clearance by intraoperative enteroscopy in the Peutz-Jeghers syndrome. Dis Colon Rectum. 2003; 46 48-50
- 20 Mignona M D, Lo Muzio L, Ruoppo E. et al . Oral manifestation of idiopathic lenticular mucocutaneous pigmentation (Laugier-Hunziker syndrome): a clinical, histopathological and ultrastructural review of 12 cases. Oral Dis. 1999; 5 80-86
J. M. Soares, M. D.
Department of Gastroenterology, Hospital de Santo António
Rua Tristão da Cunha 99 · 4150-738 Porto · Portugal
Fax: +22-2088109
Email: j.mso@clix.pt