Abstract
We evaluated the biomechanical behavior of the endoscopic decompression for lumbar spondylolysis using the finite element technique. An experimentally validated, 3-dimensional, non-linear finite element model of the intact L3 - 5 segment was modified to create the L4 bilateral spondylolysis and left-sided endoscopic decompression. The model of Gill's laminectomy (conventional decompression surgery of the spondylolysis) was also created. The stress distributions in the disc and endplate regions were analyzed in response to 400 N compression and 10.6 Nm moment in clinically relevant modes. The results were compared among three models. During the flexion motion, the pressure in the L4/5 nucleus pulposus was 0.09, 0.09 and 0.16 (MPa) for spondylolysis, endoscopic decompression and Gill's procedure, respectively. The corresponding stresses in the annulus fibrosus were 0.65, 0.65 and 1.25 (MPa), respectively. The stress at the adjoining endplates showed an about 2-fold increase in the Gill's procedure compared to the other two models. The stress values for the endoscopic and spondylolysis models were of similar magnitudes. In the other motions, i. e., extension, lateral bending, or axial rotation, the results were similar among all of the models. These results indicate that the Gill's procedure may lead to an increase in intradiscal pressure (IDP) and other biomechanical parameters after the surgery during flexion, whereas the endoscopic decompression did not change the segment mechanics after the surgery, as compared to the spondylolysis alone case. In conclusion, endoscopic decompression of the spondylolysis, as a minimally invasive surgery, does not alert mechanical stability by itself.
Key words
Spondylolysis - finite element method - biomechanics - endoscopic surgery
References
1
Sairyo K, Katoh S, Sakamaki T, Komatsubara S, Endo K, Yasui N.
Three successive stress fractures at the same vertebral level in an adolescent baseball player.
Am J Sports Med.
2003;
31
606-610
2
Wiltse L L, Wilden Jr E H, Jackson D W.
Fatigue fracture. The basic lesion in isthmic spondylolisthesis.
J Bone Joint Surg Am.
1975;
57
17-22
3
Beutler W J, Fredrickson B E, Murtland A, Sweeney C A, Grant W D, Baker D.
The natural history of spondylolysis and spondylolisthesis: 45-year follow-up evaluation.
Spine.
2003;
28
1027-1035
4
Fredrickson B E, Baker D, McHolick W J. et al .
The natural history of spondylolysis and spondylolisthesis.
J Bone Joint Surg Am.
1984;
66
699-707
5
Buck J E.
Direct repair of the defect in spondylolisthesis. Preliminary report.
J Bone Joint Surg Br.
1970;
52
432-437
6
Nicol R O, Scott J H.
Lytic spondylolysis. Repair by wiring.
Spine.
1986;
11
1027-1030
7
Gill G G, Manning J G, White H L.
Surgical treatment of spondylolisthesis without spine fusion.
J Bone Joint Surg Am.
1955;
37
493-520
8
DeWald R L, Faut M M, Taddonio R F, Neuwirth M G.
Severe lumbosacral spondylolisthesis in adolescents and children. Reduction and staged circumferential fusion.
J Bone Joint Surg Am.
1981;
63
619-626
9
Seitsalo S.
Operative and conservative treatment of moderate spondylolisthesis in young patients.
J Bone Joint Surg Br.
1990;
72
908-913
10
Davis I S, Bailey R W.
Spondylolisthesis. Indications for lumbar nerve root decompression and operative technique.
Clin Orthop.
1976;
117
129-134
11
Osterman K, Lindholm T S, Laurent L E.
Late results of removal of the loose posterior element (Gill's operation) in the treatment of lytic lumbar spondylolisthesis.
Clin Orthop.
1976;
117
121-128
12
Sairyo K, Katoh S, Sakamaki T, Komatsubara S, Yasui N.
A new endoscopic technique to decompress lumbar nerve roots affected by spondylolysis. Technical note.
J Neurosurg.
2003;
98 (3 Suppl)
290-293
13
Dooris A P, Goel V K, Grosland N M, Gilbertson L G, Wilder D G.
Load sharing between anterior and posterior elements in a lumbar motion segment with an artificial Disc.
Spine.
2001;
26
E122-129
14
Goel V K, Lim T H, Gwon J, Chen J Y, Winterbottom J M, Park J B, Weinstein J N, Ahn J Y.
Effects of rigidity of an internal fixation device - A comprehensive biomechanical investigation.
Spine.
1991;
16 (Suppl)
S155-S161
15
Goel V K, Monroe B T, Gilbertson L G, Brinckmann P.
lnterlaminar shear stresses and laminae separation in a disc: Finite element analysis of the L3 - 4 motion segment subjected to axial compressive loads.
Spine.
1995;
20
689-698
16
Goel V K, Ramirez S A, Kong W Z, Gilbertson L G.
Cancellous bone Young's modulus variation within the vertebral body of a ligamentous lumbar spine - Application of bone adaptive remodeling concepts.
J Biomech Engrg.
1995;
117
266-271
17
Kong W Z, Goel V K.
Ability of the finite element models to predict response of the human spine to sinusoidal vertical vibration.
Spine.
2003;
28
1961-1967
18
Konz R J, Goel V K, Grobler L J, Grosland N M, Spratt K F, Seifert J L, Sairyo K.
The pathomechanics of spondylolytic spondylolisthesis in immature primate lumbar spines - In vitro and finite element studies.
Spine.
2001;
26
E38-E49
19
Sairyo K, Katoh S, Sasa T, Yasui N, Goel V K, Vadapalli S, Masuda A, Biyani A, Ebraheim N.
Athletes with unilateral spondylolysis are at risk of stress fracture at the contralateral pedicle and pars interarticularis: A clinical and biomechanical study.
Am J Sports Med.
2005;
33
583-590
20
Foley K T, Smith M M.
Microendoscopic discectomy.
Techniques in Neurosurgery.
1997;
3
301-307
21
Khoo L T, Fessler R G.
Microendoscopic decompressive laminotomy for the treatment of lumbar stenosis.
Neurosurgery.
2002;
51
146-154
22
Saringer W F, Reddy B, Nobauer-Huhmann I, Regatschnig R, Reddy M, Tschabitscher M, Knosp E.
Endoscopic anterior cervical foraminotomy for unilateral radiculopathy: anatomical morphometric analysis and preliminary clinical experience.
J Neurosurg Spine.
2003;
98
171-180
23
Yuguchi T, Nishio M, Akiyama C, Ito M, Yoshimine T.
Posterior microendoscopic surgical approach for the degenerative cervical spine.
Neurol Res.
2003;
25
17-21
24
Adamson T E.
Microendoscopic posterior cervical laminoforaminotomy for unilateral radiculopathy: results of a new technique in 100 cases.
J Neurosurg Spine.
2001;
95
51-57
25
Ahn Y, Lee S H, Park W M, Lee H Y.
Posterolateral percutaneous endoscopic lumbar foraminotomy for L5 - S1 foraminal or lateral exit zone stenosis. Technical note.
J Neurosurg Spine.
2003;
99
320-323
Vijay K. Goel, Ph. D.
Spine Research Center · Department of Bioengineering · College of Engineering
5051 C Nitschke Hall
University of Toledo
Toledo OH 43606
USA ·
Telefon: +1-419-530-8035
Fax: +1-419-530-8076
eMail: viiay.goeJ@utoledo.edu