Abstract
Objective: Logistics in the run-up to computer-assisted lateral skull base intervention can
be reduced by markerless registration methods. So far, only the facial skin surface
but not the skin surface that was near to the lateral skull base was used for markerless
patient registration. The present study was designed to evaluate whether the auricles
may serve as an accurate spatial reference for markerless patient registration in
image-guided lateral skull base surgery. Study Design: In a prospective clinical study, the precision of markerless patient registration
was checked by using periauricular evaluation markers and additional distant oral
evaluation markers that served as targets for the infrared pointer of a navigation
system. Ten patients with cranial tumors, bony malformations, or foreign bodies who
were planned for image-guided surgery were selected. Markerless patient registration
was performed by laser-scanning with the SSN++ navigation system. Results: Based on the auricle, a high accuracy (mean target detection error tde = 0.9 mm ± s = 0.3 mm) was achieved in markerless patient registration as long as
the auricle was not deformed during CT imaging or during laser scanning. However,
the conventional CT acquisition with a head support caused temporary auricular deformations
in half of the patients, which made a precise laser-scan registration impossible.
Conclusions: Automated laser registration of the auricle reduces the logistical input in connection
with computer-assisted lateral skull base surgery, ensuring the accuracy that has
been achieved up to now with marker-based methods. Constantly good results can be
achieved if the head support of the computer tomograph has an appropriate opening
at the level of the auricles in order to avoid auricular deformations during CT acquisition.
Key words
Markerless patient registration - image-guided surgery - lateral skull base - auricle
References
- 1
Gunkel A R, Freysinger W, Thumfart W F.
Experience with various 3-dimensional navigation systems in head and neck surgery.
Arch Otolaryngol Head Neck Surg.
2000;
126
390-395
- 2
Cartellieri M, Vorbeck F, Kremser J.
Comparison of six three-dimensional navigation systems during sinus surgery.
Acta Otolaryngol.
2001;
121
500-504
- 3
Metson R, Gliklich R E, Cosenza M.
A comparison of image guidance systems for sinus surgery.
Laryngoscope.
1998;
108
1164-1170
- 4
Claes J, Koekelkoren E, Wuyts F L, Claes G M, Hauwe L van den, Heyning P H van de.
Accuracy of computer navigation in ear, nose, throat surgery: the influence of matching
strategy.
Arch Otolaryngol Head Neck Surg.
2000;
126
1462-1466
- 5
Albritton F D, Kingdom I T, DelGaudio J M.
Malleable registration mask: application of a novel registration method in image guided
sinus surgery.
Am J Rhinol.
2001;
15
219-224
- 6
Caversaccio M, Zulliger D, Bachler R, Nolte L P, Hausler R.
Practical aspects for optimal registration (matching) on the lateral skull base with
an optical frameless computer-aided pointer system.
Am J Otol.
2000;
21
863-870
- 7
Howard 3rd
M A, Dobbs M B, Simonson T M, LaVelle W E, Granner M A.
A noninvasive, reattachable skull fiducial marker system. Technical note.
J Neurosurg.
1995;
83
372-376
- 8
Raabe A, Krishnan R, Wolff R, Hermann E, Zimmermann M, Seifert V.
Laser surface scanning for patient Registration in intracranial image-guided surgery.
Neurosurgery.
2002;
50
797-803
- 9
Marmulla R, Mühling J, Wirtz C R, Hassfeld S.
High-resolution laser surface scanning for patient registration in cranial computer-assisted
surgery.
Minim Invas Neurosurg.
2004;
47
72-79
- 10
Marmulla R, Niederdellmann H.
Computer-assisted bone segment navigation.
J Craniomaxillofac Surg.
1998;
26
347-359
- 11 http://www.minolta-3d.com/products/eng/vi900-tech-en.html
- 12
Hassfeld S, Mühling J, Zoller J.
Intraoperative navigation in oral and maxillofacial surgery.
Int J Oral Maxillofac Surg.
1995;
24
111-119
- 13 Bronstein I N, Semendjejeww K A. Taschenbuch der Mathematik. Stuttgart: Teubner-Verlag
1991
Priv.-Doz.
Dr. Dr. Rudiger Marmulla
Department of Cranio-Maxillofacial Surgery · University of Heidelberg
Im Neuenheimer Feld 400
69120 Heidelberg
Germany
Phone: +49-6221-567-301 ·
Fax: +49-6221-564-222
Email: Ruediger_Marmulla@med.uni-heidelberg.de