Subscribe to RSS
DOI: 10.1055/s-2005-871009
Telecoils: Issues and Relevancy
Publication History
Publication Date:
24 May 2005 (online)

ABSTRACT
What a hearing aid user hears through a telecoil via inductive coupling is as important as what he or she hears via the microphone, yet many audiologists and the hearing aid industry in general have not put much time and energy into either the advancement of telecoil circuitry or the proper fitting of the circuit. Coupling techniques for telephones as well as for assistive listening devices are discussed in this article. ANSI standard S3.22 (1996) is described and methods for telecoil evaluation are presented. The current status of telecoils for both telephone communication and as assistive listening system receivers is reviewed.
KEYWORDS
Telecoil - induction coil - electromagnetic energy - telephones - assistive listening devices
REFERENCES
- 1 Kochkin S. MarkeTrak VI: consumers rate improvements sought in hearing instruments. Hear Rev. 2002; 9 18-22
- 2 Holmes A, Kaplan H, Yanke R. Tell us your telephone troubles; using open-ended questionnaires to explore telephone use. J Acad Rehab Audiol. 1998; 31 87-96
- 3 Kepler L J, Terry M, Sweetman R H. Telephone usage in the hearing-impaired population. Ear Hear. 1992; 13 311-319
- 4 Strom K E. The HR 2003 dispenser survey. Hear Rev. 2003; 10 22-38
- 5 Ross M. Telecoils: the powerful assistive listening device. Hear Rev. 2002; 9 22-27
- 6 Myers D. The coming audiocoil revolution. Hear Rev. 2002; 9 28-31
- 7 American National Standards Institute . Specification of Hearing Aid Characteristics: ANSI S3.22. ANSI. 1976;
- 8 Teder H. Quantifying telecoil performance: understanding historical and current ANSI standards. Semin Hear. 2002; 24 63-70
- 9 American National Standards Institute .Specification of Hearing Aid Characteristics. ANSI S3.22; ANSI 1996
- 10 Rodriguez G, Meyers C, Holmes A. Hearing aid performance under acoustic and electromagnetic coupling conditions. Volta Review. 1991; 93 89-95
- 11 Yanz J L, Preves D. Telecoils: principles, pitfalls, fixes, and the future. Semin Hear. 2002; 24 29-41
- 12 Mueller H G. Assessment of telecoils and assistive listening devices. In: Mueller HG, Hawkins D, Northern J Probe Microphone Measurements: Hearing Aid Selection and Assessment. San Diego, CA; Singular Press 1992: 227-251
- 13 Yanz J L, Perhringer J. Quantifying telecoil performance in the ear: common practices and a new protocol. Semin Hear. 2002; 24 71-80
Mark RossPh.D.
Communication Sciences Dept., University of Connecticut
9 Thomas Drive
Storrs, CT 06268