ABSTRACT
Radiography is the mainstay of the imaging evaluation of the prosthetic hip, but arthrography, aspiration, scintigraphy, sonography, computed tomography, and magnetic resonance imaging all have roles in the evaluation of the painful prosthesis. This article reviews the appearance of normal hip arthroplasty as well as the appearances of potential complications.
KEYWORDS
Hip - arthroplasty - replacement - complications - imaging - CT - MRI
REFERENCES
1 Eftekhar N S. Total Hip Arthroplasty. St. Louis, MO; Mosby-Year Book 1993: 3-14
2
Habermann E T.
Total joint replacement: an overview.
Semin Roentgenol.
1986;
21
7-19
3
Freiberger R H.
Evaluation of the hip prosthesis.
Semin Roentgenol.
1986;
21
20-28
4
Charnley J.
The long-term results of low-friction arthroplasty of the hip performed as a primary intervention.
J Bone Joint Surg Br.
1972;
54
61-66
5
Berry D J, Harmsen W S, Cabanela M E, Morrey B F.
Twenty-five year survivorship of two thousand consecutive primary Charnley total hip replacements: factors affecting survivorship of acetabular and femoral components.
J Bone Joint Surg Am.
2002;
84
171-177
6
Griffiths H J, Priest D R, Kushner D.
Total hip replacement and other orthopedic hip procedures.
Radiol Clin North Am.
1995;
33
267-287
7
Ritter M A.
The cemented acetabular component of a total hip replacement: all polyethylene versus metal backing.
Clin Orthop Relat Res.
1995;
311
69-75
8
Gruen T A, McNeice G M, Amstutz H C.
“Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening.
Clin Orthop Relat Res.
1979;
(141)
17-27
9
Barrack R L.
Early failure of modern cemented stems.
J Arthroplasty.
2000;
15
1036-1050
10
Manaster B.
Total hip arthroplasty: radiographic evaluation.
Radiographics.
1996;
16
645-660
11
Kaplan P A, Montesi S A, Jardon O M, Gregory P R.
Bone-ingrowth hip prostheses in asymptomatic patients: radiographic features.
Radiology.
1988;
169
221-227
12
Della Valle A G, Zoppi A, Peterson M GE, Salvati E A.
Clinical and radiographic results associated with a modern, cementless modular cup design in total hip arthroplasty.
J Bone Joint Surg Am.
2004;
86
1998-2004
13
Tigges S, Stiles R G, Roberson J R.
Complications of hip arthroplasty causing periprosthetic radiolucency on plain radiographs.
AJR Am J Roentgenol.
1994;
162
1387-1391
14
Sarmiento A, Natarjan V, Gruen T A, McMahon M.
Radiographic performance of two different total hip cemented arthroplasties: a survivorship analysis.
Orthop Clin North Am.
1988;
19
505-515
15
Ebramzadeh E, Normand P L, Sangiorgio S N et al..
Long-term radiographic changes in cemented total hip arthroplasty with six designs of femoral components.
Biomaterials.
2003;
24
3351-3363
16
Clohisy J C, Calvert G, Tull F, McDonald D, Maloney W J.
Reasons for revision hip surgery: a retrospective review.
Clin Orthop Relat Res.
2004;
429
188-192
17
Johnston R C, Fitzgerald R H, Harris W H, Muller M E, Sledge C B.
Clinical and radiographic evaluation of total hip replacement.
J Bone Joint Surg Am.
1990;
72
161-168
18
Khalily C, Whiteside L A.
Predictive value of early radiographic findings in cementless total hip arthroplasty femoral components: an 8-to-12 year follow-up.
J Arthroplasty.
1998;
13
768-773
19
von Knoch M, Sychterz C J, Engh Jr C A, Engh Sr C A.
Incidence of late bead shedding from uncemented porous coated cups. A radiographic evaluation.
Clin Orthop Relat Res.
1997;
342
99-105
20
Slullitel G, Della Valle A G, Buttaro M, Piccaluga F.
Early bead shedding of the Vitalock acetabular cup-a report on 7 cases.
Acta Orthop Scand.
2003;
74
658-660
21
DeLee J G, Charnley J.
Radiological demarcation of cemented sockets in total hip replacement.
Clin Orthop Relat Res.
1976;
121
20-32
22
Sarmiento A, Ebramzadeh E, Gogan W J, McKellop H A.
Total hip arthroplasty with cement. A long-term radiographic analysis in patients who are older than fifty and younger than fifty years.
J Bone Joint Surg Am.
1990;
72
1470-1476
23
Weissman B N.
Imaging of total hip replacement.
Radiology.
1997;
202
611-623
24
Engh Jr C A, Sychterz C J, Young A M, Pollock D C, Toomey S D, Engh Sr C A.
Interobserver and intraobserver variability in radiographic assessment of osteolysis.
J Arthroplasty.
2002;
17
752-759
25
Barrack R L, Tanzer M, Kattapuram S V, Harris W H.
The value of contrast arthrography in assessing loosening of symptomatic uncemented total hip components.
Skeletal Radiol.
1994;
23
37-41
26
Murray W R, Rodrigo J J.
Arthrography for the assessment of pain after total hip replacement. A comparison of arthrographic findings in patients with and without pain.
J Bone Joint Surg Am.
1975;
57
1060-1065
27
O'Neill D A, Harris W H.
Failed total hip replacement: assessment by plain radiographs, arthrograms, and aspiration of the hip joint.
J Bone Joint Surg Am.
1984;
66
540-546
28
Hendrix R W, Wixson R L, Rana N A, Rogers L F.
Arthrography after total hip arthroplasty: a modified technique used in the diagnosis of pain.
Radiology.
1983;
148
647-652
29
Hardy D C, Reinus W R, Totty W G, Keyser C K.
Arthrography after total hip arthroplasty: utility of postambulation radiographs.
Skeletal Radiol.
1988;
17
20-23
30
Resnik C S, Fratkin M J, Cardea J A.
Arthroscintigraphic evaluation of the painful total hip prosthesis.
Clin Nucl Med.
1986;
11
242-244
31
Swan J S, Braunstein E M, Wellman H N, Capello W.
Contrast and nuclear arthrography in loosening of the uncemented hip prosthesis.
Skeletal Radiol.
1991;
20
15-23
32
Horowitz S M, Doty S B, Lane J M, Burstein A H.
Studies of the mechanism by which the mechanical failure of polymethylmethacrylate leads to bone resorption.
J Bone Joint Surg Am.
1993;
75
802-813
33
Haynes D R, Rogers S D, Hay S, Pearcy M J, Howie D W.
The differences in toxicity and release of bone-resorbing mediators induced by titanium and cobalt-chromium-alloy wear particles.
J Bone Joint Surg Am.
1993;
75
825-834
34
Maloney W J, Smith R L, Castro F, Schurman D J.
Fibroblast response to metallic debris in vitro: enzyme induction, cell proliferation, and toxicity.
J Bone Joint Surg Am.
1993;
75
835-844
35
Santavirta S, Hoikka V, Eskola A, Konttinen Y T, Paavilainen T, Tallroth K.
Aggressive granulomatous lesions in cementless total hip arthroplasty.
J Bone Joint Surg Br.
1990;
72
980-983
36
Konttinen Y T, Zhao D, Beklen A et al..
The microenvironment around total hip replacement prostheses.
Clin Orthop Relat Res.
2005;
430
28-38
37
Della Valle A G, Ruzo P S, Li S, Pellicci P, Sculco T P, Salvati E A.
Dislodgment of polyethylene liners in first and second generation Harris-Galante acetabular components: a report of eighteen cases.
J Bone Joint Surg Am.
2001;
83
553-559
38
Huk O L, Bansal M, Betts F et al..
Polyethylene and metal debris generated by non-articulating surfaces of modular acetabular components.
J Bone Joint Surg Br.
1994;
76
568-574
39
Morscher E W, Hefti A, Aebi U.
Severe osteolysis after third-body wear due to hydroxyapatite particles from acetabular cup coating.
J Bone Joint Surg Br.
1998;
80
267-272
40
McKellop H A.
Bearing surfaces in total hip replacements: state of the art and future developments.
Instr Course Lect.
2001;
50
165-179
41
Bauer T W, Schils J.
The pathology of total joint arthroplasty II: mechanisms of implant failure.
Skeletal Radiol.
1999;
28
483-497
42
Keogh C, Munk P L, Gee R, Chan L P, Marchinkow L O.
Imaging of the painful hip arthroplasty.
AJR Am J Roentgenol.
2003;
180
115-120
43
Schmalzried T P, Jasty M, Harris W H.
Periprosthetic bone loss in total hip arthroplasty.
J Bone Joint Surg Am.
1992;
74
849-863
44
Campbell D G, Garvuz D S, Masri B A, Duncan C P.
Reliability of acetabular bone defect classification systems in revision total hip arthroplasty.
J Arthroplasty.
2001;
16
83-86
45
Zimlich R H, Fehring T K.
Underestimation of pelvic osteolysis: the value of the iliac oblique radiograph.
J Arthroplasty.
2000;
15
796-801
46
Southwell D G, Bechtold J E, Lew W D, Schmidt A H.
Improving the detection of acetabular osteolysis using oblique radiographs.
J Bone Joint Surg Br.
1999;
8
289-295
47
Claus A M, Engh Jr C A, Sychterz C J, Xenos J S, Orishimo K F, Engh Sr C A.
Radiographic definition of pelvic osteolysis following total hip arthroplasty.
J Bone Joint Surg Am.
2003;
85
1519-1526
48
Walde T A, Mohan V, Leung S, Engh Sr C A.
Sensitivity and specificity of plain radiographs for detection of medial-wall perforation secondary to osteolysis.
J Arthroplasty.
2005;
20
20-24
49
Claus A M, Totterman S M, Sychterz C J, Tamez-Pena J G, Looney R J, Engh Sr C A.
Computed tomography to assess pelvic lysis after total hip replacement.
Clin Orthop Relat Res.
2004;
422
167-174
50
Dumbleton J H, Manley M T, Edidin A A.
A literature review of the association between wear rate and osteolysis in total hip arthroplasty.
J Arthroplasty.
2002;
17
649-661
51
Silva M, Heisel C, Schmalzried T P.
Metal-on-metal total hip replacement.
Clin Orthop Relat Res.
2005;
430
53-61
52
Doorn P F, Campbell P A, Worrall J, Benya P D, McKellop H A, Amstutz H C.
Metal wear particle characterization from metal on metal total hip replacements: transmission electron microscopy study of periprosthetic tissues and isolated particles.
J Biomed Mater Res.
1998;
42
103-111
53
Hannouche D, Hamadouche M, Nizard R, Bizot P, Meunier A, Sedel L.
Ceramics in total hip replacement.
Clin Orthop Relat Res.
2005;
430
62-71
54
Bos I, Willmann G.
Morphologic characteristics of periprosthetic tissues from hip prostheses with ceramic-ceramic couples.
Acta Orthop Scand.
2001;
72
335-342
55
De Aza A H, Chevalier J, Fantozzi F, Schehl M, Torrecillas R.
Crack growth resistance of alumina, zirconia and zirconia toughened alumina ceramics for joint prostheses.
Biomaterials.
2002;
23
937-945
56
Callaway G H, Flynn W, Ranawat C S, Sculco T P.
Fracture of the femoral head after ceramic-on-polyethylene total hip arthroplasty.
J Arthroplasty.
1995;
10
855-859
57
Kim Y H, Ritchie A, Hardaker C.
Surface roughness of ceramic femoral heads after in vivo transfer of metal: correlation to polyethylene wear.
J Bone Joint Surg Am.
2005;
87
577-582
58
Yoo J J, Kim Y M, Yoon K S, Koo K H, Song W S, Kim H G.
Alumina-on-alumina total hip arthroplasty: a five year follow-up study.
J Bone Joint Surg Am.
2005;
87
530-535
59
Allain J, Roudot-Thorval F, Delecrin J, Anract P, Migaud H, Goutallier D.
Revision total hip arthroplasty performed after fracture of a ceramic femoral head: a multicenter survivorship study.
J Bone Joint Surg Am.
2003;
85
825-830
60
Matziolis G, Perka C, Disch A.
Massive metallosis after revision of a fractured ceramic head onto a metal head.
Arch Orthop Trauma Surg.
2003;
123
48-50
61
Matsuda Y, Yamamuro T.
Metallosis due to abnormal abrasion of the femoral head in bipolar hip prosthesis. Implant retrieval and analysis in six cases.
Med Prog Technol.
1994;
20
185-189
62
Kempf I, Semlitsch M.
Massive wear of a steel ball head by ceramic fragments in the polyethylene acetabular cup after revision of a total hip prosthesis with fractured ceramic ball.
Arch Orthop Trauma Surg.
1990;
109
284-287
63
Masonis J L, Bourne R B, Ries M D, McCalden R W, Salehi A, Kelman D C.
Zirconia femoral head fractures: a clinical and retrieval analysis.
J Arthroplasty.
2004;
19
898-905
64
Muller M E.
The benefits of metal-on-metal total hip replacements.
Clin Orthop Relat Res.
1995;
311
54-59
65
Dorr L D, Wan Z, Longjohn D B, Dubois B, Murken R.
Total hip arthroplasty with use of the Metasul metal-on-metal articulation.
J Bone Joint Surg Am.
2000;
82
789-798
66
Jacobs J J, Skipor A K, Doorn P F et al..
Cobalt and chromium concentrations in patients with metal on metal total hip replacements.
Clin Orthop Relat Res.
1996;
329(Suppl)
S256-S263
67
Lhotka C, Szekeres T, Steffan I, Zhuber K, Zweymuller K.
Four-year study of cobalt and chromium blood levels in patients managed with two different metal-on-metal total hip replacements.
J Orthop Res.
2003;
21
189-195
68
Schaffer A W, Pilger A, Engelhardt C, Zweymuller K, Ruediger H W.
Increased blood cobalt and chromium after total hip replacement.
J Toxicol Clin Toxicol.
1999;
37
839-844
69
Maezawa K, Nozawa M, Hirose T et al..
Cobalt and chromium concentrations in patients with metal-on-metal and other cementless total hip arthroplasty.
Arch Orthop Trauma Surg.
2002;
122
283-287
70
Visuri T, Pukkala E, Paavolainen P, Pulkkinen P, Riska E B.
Cancer risk after metal on metal and polyethylene on metal total hip arthroplasty.
Clin Orthop Relat Res.
1996;
329(Suppl)
S280-S289
71
Tharani R, Dorey F J, Schmalzried T P.
The risk of cancer following total hip or knee arthroplasty.
J Bone Joint Surg Am.
2001;
83
774-780
72
Paavolainen P, Pukkala E, Pulkkinen P, Visuri T.
Cancer incidence in Finnish hip replacement patients from 1980 to 1995: a nationwide cohort study involving 31,651 patients.
J Arthroplasty.
1999;
14
272-280
73
Signorello L B, Ye W, Fryzek J P et al..
Nationwide study of cancer risk among hip replacement patients in Sweden.
J Natl Cancer Inst.
2001;
93
1405-1410
74
Doherty A T, Howell R T, Ellis L A et al..
Increased chromosome translocations and aneuploidy in peripheral blood lymphocytes of patients having revision arthroplasty of the hip.
J Bone Joint Surg Br.
2001;
83
1075-1081
75
Santavirta S, Bohler M, Harris W H et al..
Alternative materials to improve total hip replacement tribology.
Acta Orthop Scand.
2003;
74
380-388
76
Harris W H, Muratoglu O K.
A review of current cross-linked polyethylenes used in total hip arthroplasty.
Clin Orthop Relat Res.
2005;
430
46-52
77
Sakoda H, Voice A M, McEwen H M et al..
A comparison of the wear and physical properties of silane cross-linked polyethylene and ultra-high molecular weight polyethylene.
J Arthroplasty.
2001;
16
1018-1023
78
Shen F W, McKellop H.
Surface-gradient cross-linked polyethylene acetabular cups: oxidation resistance and wear against smooth and rough femoral balls.
Clin Orthop Relat Res.
2005;
430
80-88
79
Hamilton W G, McCauley J P.
Evaluation of the unstable total hip arthroplasty.
Instr Course Lect.
2004;
53
87-92
80
Soong M, Eubash H E, Macaulay W.
Dislocation after total hip arthroplasty.
J Am Acad Orthop Surg.
2004;
12
314-321
81
Shrader M W, Parvizi J, Lewallen D G.
The use of a constrained acetabular component to treat instability after total hip arthroplasty.
J Bone Joint Surg Am.
2003;
85
2179-2183
82
Amstutz H C, Le Duff M J, Beaule P E.
Prevention and treatment of dislocation after total hip replacement using large diameter balls.
Clin Orthop Relat Res.
2004;
429
108-116
83
Padgett D E, Warashina H.
The unstable total hip replacement.
Clin Orthop Relat Res.
2004;
420
72-79
84
Lachiewicz P F, Kelley S S.
The use of constrained components in total hip arthroplasty.
J Am Acad Orthop Surg.
2002;
10
233-238
85
Lachiewicz P F, Rogers G D, Thomason H C.
Aspiration of the hip joint before revision total hip arthroplasty. Clinical and laboratory factors influencing attainment of a positive culture.
J Bone Joint Surg Am.
1996;
78
749-754
86
Tigges S, Stiles R G, Roberson J R.
Appearance of septic hip prostheses on plain radiographs.
AJR Am J Roentgenol.
1994;
163
377-380
87
Cyteval C, Hamm V, Sarrabere M P, Lopez F M, Maury P, Taourel P.
Painful infection at the site of hip prosthesis: CT imaging.
Radiology.
2002;
224
477-483
88
van Holsbeeck M T, Eyler W R, Sherman L S et al..
Detection of infection in loosened hip prostheses: efficacy of sonography.
AJR Am J Roentgenol.
1994;
163
381-384
89
Weybright P N, Jacobson J A, Murry K H et al..
Limited effectiveness of sonography in revealing hip joint effusion: preliminary results in 21 adult patients with native and postoperative hips.
AJR Am J Roentgenol.
2003;
181
215-218
90
Steinbach L S, Schneider R, Goldman A B, Kazam E, Ranawat C S, Ghelman B.
Bursae and abscess cavities communicating with the hip. Diagnosis using arthrography and CT.
Radiology.
1985;
156
303-307
91
Berquist T H, Bender C E, Maus T P, Ward E M, Rand J A.
Pseudobursae: a useful finding in patients with painful hip arthroplasty.
AJR Am J Roentgenol.
1987;
148
103-106
92
Maus T P, Berquist T H, Bender C E, Rand J A.
Arthrographic study of painful total hip arthroplasty: refined criteria.
Radiology.
1987;
162
721-727
93
Teller R E, Christie M J, Martin W, Nance E P, Haas D W.
Sequential indium-labeled leukocyte and bone scans to diagnose prosthetic joint infection.
Clin Orthop Relat Res.
2000;
373
241-247
94
Barrack R L, Harris W H.
The value of aspiration of the hip joint before revision total hip arthroplasty.
J Bone Joint Surg Am.
1993;
75
66-76
95
Love C, Tomas M B, Marwin S E, Pugliese P V, Palestro C J.
Role of nuclear medicine in diagnosis of the infected joint replacement.
Radiographics.
2001;
21
1229-1238
96
Love C, Marwin S E, Tomas M B et al..
Diagnosing infection in the failed joint replacement: a comparison of coincidence detection 18 F-FDG and 111 In-labeled leukocyte/99m Tc-sulfur colloid marrow imaging.
J Nucl Med.
2004;
45
1864-1871
97
Chacko T K, Zhuang H, Stevenson K, Moussavian B, Alavi A.
The importance of the location of fluorodeoxyglucose uptake in periprosthetic infection in painful hip prostheses.
Nucl Med Commun.
2002;
23
851-855
98
Stumpe K, Notzli H P, Zannetti M et al..
FDG PET for differentiation of infection and aseptic loosening in total hip replacements: comparison with conventional radiography and three-phase bone scintigraphy.
Radiology.
2004;
231
333-341
99
Berry D J.
Epidemiology: hip and knee.
Orthop Clin North Am.
1999;
30
183-190
100
Tsiridis E, Haddad F S, Gie G A.
The management of periprosthetic femoral fractures around hip replacements.
Injury.
2003;
34
95-105
101
Ebramzadeh E, Sangiorgio S N, Lattuada F et al..
Accuracy of measurements of polyethylene wear with use of radiographs of total hip replacements.
J Bone Joint Surg Am.
2003;
85
2378-2384
102
Sychterz C J, Yang A M, McAuley J P, Engh C A.
Two-dimensional versus three-dimensional radiographic measurements of polyethylene wear.
Clin Orthop Relat Res.
1999;
365
117-123
103
Moore K D, Barrack R L, Sychterz C J, Sawhney J, Yang A M, Engh C A.
The effect of weight-bearing on the radiographic measurement of the position of the femoral head after total hip arthroplasty.
J Bone Joint Surg Am.
2000;
82
62-69
104
Sychterz C J, Engh Jr C A, Yang A, Engh C A.
Analysis of temporal wear patterns of porous-coated acetabular components: distinguishing between true wear and so-called bedding-in.
J Bone Joint Surg Am.
1999;
81
821-830
105
Werle J, Goodman S, Schurman D, Lannin J.
Polyethylene liner dissociation in Harris-Galante acetabular components.
J Arthroplasty.
2002;
17
78-81
106
Han C D, Choe W S, Yoo J H.
Late dissociation of the polyethylene liner from a modular acetabular metal shell after primary total hip-arthroplasty: a report of five cases.
Yonsei Med J.
1998;
39
277-282
107
Mihalko W M, Papdemetriou T.
Polyethylene liner dissociation with the Harris-Galante II acetabular component.
Clin Orthop Relat Res.
2001;
386
166-172
108
Su E P, Callander P W, Salvati E A.
The bubble sign: a new radiographic sign in total hip arthroplasty.
J Arthroplasty.
2003;
18
110-112
109
Della Valle A G, Ruzo P S, Pavone V, Tolo E, Mintz D N, Salvati E A.
Heterotopic ossification after total hip arthroplasty.
J Arthroplasty.
2002;
17
870-875
110
Neal B, Gray H, McMahon S, Dunn L.
Incidence of heterotopic bone formation after major hip surgery.
ANZ J Surg.
2002;
72
808-821
111
Schara K, Herman S.
Heterotopic bone formation in total hip arthroplasty: predisposing factors, classification and the significance for clinical outcome.
Acta Chir Orthop Traumatol Cech.
2001;
68
105-108
112
Kasetti R J, Shetty A A, Rand C.
Heterotopic ossification after uncemented hydroxyapatite-coated primary total hip arthroplasty.
J Arthroplasty.
2001;
16
1038-1042
113
Fransen M, Neal B.
Non-steroidal anti-inflammatory drugs for preventing heterotopic bone formation after hip arthroplasty.
Cochrane Database Syst Rev.
2004;
CD 001160
114
Brooker A F, Bowerman J W, Robinson R A, Riley Jr L H.
Ectopic ossification following total hip replacement. Incidence and a method of classification.
J Bone Joint Surg Am.
1973;
56
1629-1632
115
Wright J G, Moran E, Bogoch E.
Reliability and validity of the grading of heterotopic ossification.
J Arthroplasty.
1994;
9
549-553
116
Padgett D E, Holley K G, Cummings M et al..
The efficacy of 500 centigray radiation in the prevention of heterotopic ossification after total hip arthroplasty: a prospective, randomized, pilot study.
J Arthroplasty.
2003;
18
677-686
117
Pakos E E, Ioannidis J P.
Radiotherapy vs. nonsteroidal anti-inflammatory drugs for the prevention of heterotopic ossification after hip procedures: a meta-analysis of randomized trials.
Int J Radiat Oncol Biol Phys.
2004;
60
888-895
118
Robertson D D, Sutherland C J, Lopes T, Yuan J.
Preoperative description of severe acetabular defects caused by failed total hip replacement.
J Comput Assist Tomogr.
1998;
22
444-449
119
Puri L, Wixson R L, Stern S H, Kohli J, Hendriz R W, Stulberg S D.
Use of helical computed tomography for the assessment of acetabular osteolysis after total hip arthroplasty.
J Bone Joint Surg Am.
2002;
84
609-614
120
Leung S, Naudie D, Kitamura N, Walde T, Engh C A.
Computed tomography in the assessment of periacetabular osteolysis.
J Bone Joint Surg Am.
2005;
87
592-597
121
Reinus W R, Merkel K C, Gilden J J, Berger K L.
Evaluation of femoral prosthetic loosening using CT imaging.
AJR Am J Roentgenol.
1996;
166
1439-1442
122
Mian S W, Truchly G, Pflum F A.
Computed tomography measurement of acetabular cup anteversion and retroversion in total hip arthroplasty.
Clin Orthop Relat Res.
1992;
276
206-209
123
Nishii T, Sugano N, Miki H, Koyama T, Takao M, Yoshikawa H.
Influence of component positions on dislocation: computed tomographic evaluations in a consecutive series of total hip arthroplasty.
J Arthroplasty.
2004;
19
162-166
124
Olivecrona H, Weidenhielm L, Olivecrona L et al..
A new CT method for measuring cup orientation after total hip arthroplasty.
Acta Orthop Scand.
2004;
75
252-260
125
White L M, Kim J K, Mehta M et al..
Complications of total hip arthroplasty: MR imaging-initial experience.
Radiology.
2000;
215
254-262
126
Potter H G, Nestor B J, Sofka C M, Ho S T, Peters L E, Salvati E A.
Magnetic resonance imaging after total hip arthroplasty: evaluation of periprosthetic soft tissue.
J Bone Joint Surg Am.
2004;
86
1947-1954
127
Sugimoto H, Hirose I, Miyaoka E et al..
Low-field strength MR imaging of failed hip arthroplasty: association of femoral periprosthetic signal intensity with radiographic, surgical, and pathological findings.
Radiology.
2003;
229
718-723
128
Twair A, Ryan M, O'Connell M, Powell T, O'Byrne J, Eustace S.
MRI of failed total hip replacement caused by abductor muscle avulsion.
AJR Am J Roentgenol.
2003;
181
1547-1550
129
Cook S M, Pellicci P M, Potter H G.
Use of magnetic resonance imaging in the diagnosis of occult fracture of the femoral component after total hip arthroplasty.
J Bone Joint Surg Am.
2004;
86
149-153
Theodore T MillerM.D.
Chief, Division of Musculoskeletal Imaging, Department of Radiology, North Shore University Hospital and Long Island Jewish Medical Center
825 Northern Blvd., Great Neck, NY 11021