Methods Inf Med 2010; 49(05): 435-442
DOI: 10.3414/ME10-02-0029
Special Topic – Original Articles
Schattauer GmbH

Time-varying Methods for Characterizing Nonstationary Dynamics of Physiological Systems

N. Selvaraj
1   Department of Biomedical Engineering, Worcester Polytechnic Institute, Worcester, MA, USA
,
J. Lee
1   Department of Biomedical Engineering, Worcester Polytechnic Institute, Worcester, MA, USA
,
K. H. Chon
1   Department of Biomedical Engineering, Worcester Polytechnic Institute, Worcester, MA, USA
› Author Affiliations
Further Information

Publication History

received: 28 July 2010

accepted: 13 August 2010

Publication Date:
17 January 2018 (online)

Summary

Background: Accurate and early diagnosis of various diseases and pathological conditions require analysis techniques that can capture time-varying (TV) dynamics. In the pursuit of promising TV signal processing methods applicable to real-time clinical monitoring applications, nonstationary spectral techniques are of great significance.

Objectives: We present two potential practical applications of such techniques in quantifying TV physiological dynamics concealed in photoplethysmography (PPG) signals: early detection of blood-volume loss using a non-parametric approach known as variable frequency complex demodulation (VFCDM), and accurate detection of abrupt changes in respiratory rates using a parametric approach known as combined optimal parameter search and multiple mode particle filtering (COPS-MPF).

Methods: The VFCDM technique has been tested using ear-PPG signals in two study models: mechanically ventilated patients undergoing surgery in operating room settings and spontaneously breathing conscious healthy subjects subjected to lower body negative pressure (LBNP) in laboratory settings. Extraction of respiratory rates has been tested using COPS-MPF technique in finger-PPG signals collected from healthy volunteers with abrupt changes in respiratory rate ranging from 0.1 to 0.4 Hz.

Results: VFCDM method showed promise to detect the blood loss noninvasively in mechanical ventilated patients well before blood losses become apparent to the physician. In spontaneously breathing subjects during LBNP experiments, the early detection and quantification of blood loss was possibleat 40% of LBNP tolerance. COPS-MPF showed high accuracy in detecting the constant as well as sudden changes in respiratory rates as compared to other time-invariant methods.

Conclusion: Integration of such robust algorithms into pulse oximeter device may have significant impact in real-time clinical monitoring and point-of-care healthcare settings.

 
  • References

  • 1 Faes L, Zhao H, Chon KH, Nollo G. Time-varying surrogate data to assess nonlinearity in nonstationary time series: application to heart rate variability. IEEE Trans Biomed Eng 2009; 56 (03) 685-695.
  • 2 Zhong Y, Jan KM, Ju KH, Chon KH. Quantifying cardiac sympathetic and parasympathetic nervous activities using principal dynamic modes analysis of heart rate variability. Am J Physiol Heart Circ Physiol 2006; 291 (03) H1475-1483.
  • 3 Maier C, Dickhaus H. Central Sleep Apnea Detection from ECG-derived Respiratory Signals Application of Multivariate Recurrence Plot Analysis. Methods Inf Med 2010; 49 (05) 462-466.
  • 4 Voss A, Fischer C, Schroeder R, Figulla HR, Goernig M. Segmented Poincaré Plot Analysis for Risk Stratification in Patients with Dilated Cardiomyopathy. Methods Inf Med 2010; 49 (05) 511-515.
  • 5 Corino VDA, Belletti S, Terranova P, Lombardi F, Mainardi LT. Heart Rate and Systolic Blood Pressure in Patients with Persistent Atrial Fibrillation A Linguistic Analysis. Methods Inf Med 2010; 49 (05) 516-520.
  • 6 Bianchi AM, Mendez MO, Ferrario M, FeriniStrambi L, Cerutti S. Long-term Correlations and Complexity Analysis of the Heart Rate Variability Signal during Sleep Comparing Normal and Pathological Subjects. Methods Inf Med 2010; 49 (05) 479-483.
  • 7 Deburchgraeve W, Cherian PJ, De Vos M, Swarte RM, Blok JH, Visser GH, Govaert P, Van Huffel S. Time Varying Neonatal Seizure Localization. Methods Inf Med 2010; 49 (05) 473-478.
  • 8 Erla S, Faes L, Nollo G. Quantifying Changes in EEG Complexity Induced by Photic Stimulation. Methods Inf Med 2010; 49 (05) 496-500.
  • 9 Leistritz L, Weiss T, Ionov J, Bar KJ, Miltner WHR, Witte H. Connectivity Analysis of Somatosensory Evoked Potentials in Patients with Major Depression. Methods Inf Med 2010; 49 (05) 484-491.
  • 10 Chon KH, Dash S, Ju K. Estimation of respiratory rate from photoplethysmogram data using time-frequency spectral estimation. IEEE Trans Biomed Eng 2009; 56 (08) 2054-2063.
  • 11 Garde A, Giraldo BF, Jane R, Sornmo L. Time-varying respiratory pattern characterization in chronic heart failure patients and healthy subjects. Conf Proc IEEE Eng Med Biol Soc. 2009 pp 4007-4010.
  • 12 Taelman J, Deburchgraeve W, Van Damme K, Adriaensen T, Spaepen A, Van Huffel S. Detection Algorithm for Single Motor Unit Firing in Surface EMG of the Trapezius Muscle. Methods Inf Med 2010; 49 (05) 492-495.
  • 13 Zhang ZG, Liu HT, Chan SC, Luk KD, Hu Y. Time-dependent power spectral density estimation of surface electromyography during isometric muscle contraction: methods and comparisons. J Electro-myogr Kinesiol 2010; 20 (01) 89-101.
  • 14 O’Neal 3rd MH, Spiegel ET, Chon KH, Solomon IC. Time-frequency representation of inspiratory motor output in anesthetized C57BL/6 mice in vivo. J Neurophysiol 2005; 93 (03) 1762-1775.
  • 15 Siu KL, Sung B, Cupples WA, Moore LC, Chon KH. Detection of low-frequency oscillations in renal blood flow. Am J Physiol Renal Physiol 2009; 297 (01) F155-162.
  • 16 Chon KH, Zhong Y, Moore LC, Holstein-Rathlou NH, Cupples WA. Analysis of nonstationarity in renal autoregulation mechanisms using time-varying transfer and coherence functions. Am J Physiol Regul Integr Comp Physiol 2008; 295 (03) R821-828.
  • 17 Yang B, Chon KH. A Novel Approach to Monitor Nonstationary Dynamics in Physiological Signals: Application to Blood Pressure, Pulse Oximeter, and Respiratory Data. Ann Biomed Eng. 2010 (in press).
  • 18 Di Rienzo M, Castiglioni P, Rizzo F, Faini A, Mazzoleni P, Lombardi C. et al. Linear and Fractal Heart Rate Dynamics during Sleep at High Altitude Investigation with Textile Technology. Methods Inf Med 2010; 49 (05) 521-525.
  • 19 Gonzalez-Camarena R, Charleston-Villalobos S, Angeles-Olguin A, Aljama-Corrales T. Imaging the Thoracic Distribution of Normal Breath Sounds. Methods Inf Med 2010; 49 (05) 443-447.
  • 20 Vallais F, Porta A, Lucini D, Pagani M, Aletti F, Baselli G. Interferences between Baroreflex and Respiration Evaluation by Symbolic Analysis and Conditional Entropy. Methods Inf Med 2010; 49 (05) 501-505.
  • 21 Porta A, Catai AM, Takahashi ACM, Magagnin V, Bassani T, Tobaldini E, Montano N. Information Transfer through the Spontaneous Baroreflex in Healthy Humans. Methods Inf Med 2010; 49 (05) 506-510.
  • 22 Faes L, Nollo G. Assessing Frequency Domain Causality in Cardiovascular Time Series with Instantaneous Interactions. Methods Inf Med 2010; 49 (05) 453-457.
  • 23 Mijovic B, Silva M, Van den Bergh BRH, Allegaert K, Aerts JM, Berckmans D, Van Huffel S. Assessment of Pain Expression in Infant Cry Signals Using Empirical Mode Decomposition. Methods Inf Med 2010; 49 (05) 448-452.
  • 24 Polat H, Guler I. A simple computer-based measurement and analysis system of pulmonary auscultation sounds. J Med Syst 2004; 28 (06) 665-672.
  • 25 Lin Z, Chen JD. Advances in time-frequency analysis of biomedical signals. Crit Rev Biomed Eng 1996; 24 (01) 1-72.
  • 26 Papo D, Caverni JP, Douiri A, Podlipsky I, Baudonniere PM. Time-varying spectral entropy differentiates between positive and negative feed back-related EEG activity in a hypothesis testing paradigm. Int J Psychophysiol 2007; 66 (03) 183-195.
  • 27 Figueroa Helland VC, Gapelyuk A, Suhrbier A, Riedl M, Penzel T, Kurths J, Wessel N. Investigation of an Automatic Sleep Stage Classification by Means of Multiscorer Hypnogram. Methods Inf Med 2010; 49 (05) 467-472.
  • 28 Kishi A, Yasuda H, Matsumoto T, Inami Y, Horiguchi J, Struzik ZR, Yamamoto Y. Sleep Stage Transitions in Healthy Humans Altered by Central Monoaminergic Antagonist. Methods Inf Med 2010; 49 (05) 458-461.
  • 29 Stoica P, Moses P. Introduction to spectral analysis. Prentice Hall; 1997
  • 30 Zou R, Chon KH. Robust algorithm for estimation of time-varying transfer functions. IEEE Trans Biomed Eng 2004; 51 (02) 219-228.
  • 31 Zou R, Wang H, Chon KH. A robust time-varying identification algorithm using basis functions. Ann Biomed Eng 2003; 31 (07) 840-853.
  • 32 Lee J, Chon K. An Autoregressive Model-Based Particle Filtering Algorithms for Extraction of Respiratory Rates as High as 90 Breaths per Minute from Pulse Oximeter. IEEE Trans Biomed Eng 2010; 57 (09) 2158-2167.
  • 33 Wang H, Siu K, Ju K, Chon KH. A high resolution approach to estimating time-frequency spectra and their amplitudes. Ann Biomed Eng 2006; 34 (02) 326-338.
  • 34 Zhao H, Ju K, Chon KH. An approach to estimate time-varying casual coherence function. Methods Inf Med 2007; 46 (02) 102-109.
  • 35 Zhao H, Lu S, Zou R, Ju KW, Chon KH. Estimation of time-varying coherence function using time-varying transfer functions. Ann Biomed Eng 2005; 33 (11) 1582-1594.
  • 36 Pande P, Trivedi CA, Jo JA. Analysis of Fluorescence Lifetime Imaging Microscopy (FLIM) Data Based on a Fully Automated Laguerre Deconvolution Method. Methods Inf Med 2010; 49 (05) 531-536.
  • 37 Wilson M, Davis DP, Coimbra R. Diagnosis and monitoring of hemorrhagic shock during the initial resuscitation of multiple trauma patients: a review. J Emerg Med 2003; 24 (04) 413-422.
  • 38 McGrath SP, Ryan KL, Wendelken SM, Rickards CA, Convertino VA. Pulse Oximeter Plethysmo-graphic Waveform Changes in Awake, Spontaneously Breathing, Hypovolemic Volunteers. Anesth Analg. 2010 DOI: ANE.0b013e3181cb3f4a.
  • 39 Cannesson M, Attof Y, Rosamel P, Desebbe O, Joseph P, Metton O. et al. Respiratory variations in pulse oximetry plethysmographic waveform amplitude to predict fluid responsiveness in the operating room. Anesthesiology 2007; 106 (06) 1105-1111.
  • 40 Wyffels PA, Durnez PJ, Helderweirt J, Stockman WM, De Kegel D. Ventilation-induced plethysmo-graphic variations predict fluid responsiveness in ventilated postoperative cardiac surgery patients. Anesth Analg 2007; 105 (02) 448-452.
  • 41 Golparvar M, Naddafnia H, Saghaei M. Evaluating the relationship between arterial blood pressure changes and indices of pulse oximetric plethysmography. Anesth Analg 2002; 95 (06) 1686-1690.
  • 42 Landsverk SA, Hoiseth LO, Kvandal P, Hisdal J, Skare O, Kirkeboen KA. Poor agreement between respiratory variations in pulse oximetry photoplethysmographic waveform amplitude and pulse pressure in intensive care unit patients. Anesthesiology 2008; 109 (05) 849-855.
  • 43 Tsuchiya M, Yamada T, Asada A. Pleth variability index predicts hypotension during anesthesia induction. Acta Anaesthesiol Scand 2010; 54 (05) 596-602.
  • 44 Shelley KH, Awad AA, Stout RG, Silverman DG. The use of joint time frequency analysis to quantify the effect of ventilation on the pulse oximeter waveform. J Clin Monit Comput 2006; 20 (02) 81-87.
  • 45 Clifton D, Douglas JG, Addison PS, Watson JN. Measurement of respiratory rate from the photo-plethysmogram in chest clinic patients. J Clin Monit Comput 2007; 21 (01) 55-61.
  • 46 Wendelken S, Linder S, McGrath S. editors. A preliminary study of respiratory variations in the photoplethysmogram during lower body negative pressure. Proceedings of the 19th IEEE Symposium on Computer-Based Medical Systems (CBMS’06). 2006
  • 47 Arena R, Myers J, Abella J, Peberdy MA, Bensimhon D, Chase P. et al. Development of a ventilatory classification system in patients with heart failure. Circulation 2007; 115 (18) 2410-2417.
  • 48 Zhong Y, Jan KM, Ju KH, Chon KH. Representation of time-varying nonlinear systems with time-varying principal dynamic modes. IEEE Trans Biomed Eng 2007; 54 (11) 1983-1992.
  • 49 Faes L, Nollo G, Chon KH. Assessment of Granger causality by nonlinear model identification: application to short-term cardiovascular variability. Ann Biomed Eng 2008; 36 (03) 381-395.
  • 50 Xiao X, Li Y, Mukkamala R. A model order selection criterion with applications to cardio-respiratory-renal systems. IEEE Trans Biomed Eng 2005; 52 (03) 445-453.
  • 51 Leonard P, Grubb NR, Addison PS, Clifton D, Watson JN. An algorithm for the detection of individual breaths from the pulse oximeter waveform. J Clin Monit Comput 2005; 18: 309-312.
  • 52 Leonard P, Beattie TF, Addison PS, Watson JN. Standard pulse oximeters can be used to monitor respiratory rate. Emerg Med J 2003; 20 (06) 524-525.
  • 53 Lee J, Chon KH. Respiratory Rate Extraction Via an Autoregressive Model Using the Optimal Parameter Search Criterion. Ann Biomed Eng. DOI: 10.1007/s10439-010-0080-9.