Vet Comp Orthop Traumatol 2013; 26(03): 177-185
DOI: 10.3415/VCOT-12-05-0061
Original Research
Schattauer GmbH

Ex vivo evaluation of the biomechanical effect of varying monocortical screw numbers on a plate-rod canine femoral gap model

P. J. Delisser
1   School of Veterinary Science, University of Bristol, Langford House, Langford Bristol, UK
,
G. P. McCombe
2   Department of Engineering, University of Bristol, Advanced Composites Centre for Innovation in Science, Queen's Building, Bristol, UK
,
R. S. Trask
2   Department of Engineering, University of Bristol, Advanced Composites Centre for Innovation in Science, Queen's Building, Bristol, UK
,
J. A. Etches
2   Department of Engineering, University of Bristol, Advanced Composites Centre for Innovation in Science, Queen's Building, Bristol, UK
,
A. J. German
3   Department of Obesity and Endocrinology, The University of Liverpool, Leahurst Campus, Chester High Road, Neston, UK
,
S. L. Holden
3   Department of Obesity and Endocrinology, The University of Liverpool, Leahurst Campus, Chester High Road, Neston, UK
,
A. M. Wallace
1   School of Veterinary Science, University of Bristol, Langford House, Langford Bristol, UK
,
N. J. Burton
1   School of Veterinary Science, University of Bristol, Langford House, Langford Bristol, UK
› Author Affiliations
Further Information

Publication History

Received 05 May 2012

Accepted 23 March 2012

Publication Date:
19 December 2017 (online)

Summary

Objective: To compare the biomechanical behaviour of plate-rod constructs with varying numbers of monocortical screws applied to an ex vivo canine femoral-gap ostectomy model.

Sample population: Twenty Greyhound dog cadaveric femurs.

Methods: Bone mineral density (BMD) was assessed with dual x-ray absorptiometry. Bones were assigned to four groups. Bones had a 12-hole 3.5 mm locking compression plate with one bicortical non-locking cortical screw in the most proximal and distal plate holes and an intramedullary Steinmann pin applied across a 20 mm mid-diaphyseal ostectomy. Additionally, one to four monocortical non-locking cortical screws were then placed (Groups 1–4 respectively) in the proximal and distal fragments. Stiffness and axial collapse were determined before and after cyclic axial loading (6000 cycles at 20%, 40%, and 60% of mean bodyweight [total: 18000 cycles]). Constructs subsequently underwent an additional 45000 cycles at 60% of bodyweight (total: 63000 cycles). Loading to failure was then performed and ultimate load and mode of failure recorded.

Results: The BMD did not differ significantly between groups. Construct stiffness for group 1 was significantly less than group 4 (p = 0.008). Stiffness showed a linear increase with an increasing number of monocortical screws (p = 0.001). All constructs survived fatigue loading. Load-to-failure was not significantly different between groups. Mean load- to-failure of all groups was >1350N.

Clinical relevance: Ex vivo canine large-breed femurs showed adequate stability biomechanically and gradually increasing stiffness with increasing monocortical screw numbers.

 
  • References

  • 1 Reems MR, Beale BS, Hulse DA. Use of a plate-rod construct and principles of biological osteosynthesis for repair of diaphyseal fractures in dogs and cats: 47 cases (1994-2001). J Am Vet Med Assoc 2003; 223: 330-335.
  • 2 Perren SM. Evolution of the internal fixation of long bone fractures: the scientific basis of biological internal fixation: choosing a new balance between stability and biology. J Bone Joint Surg Br 2002; 84: 1093-1110.
  • 3 Beale B. Orthopedic clinical techniques femur fracture repair. Clin Tech Small Anim Pract 2004; 19: 134-150.
  • 4 Hulse D, Hyman W, Nori M. et al. Reduction in plate strain by addition of an intramedullary pin. Vet Surg 1997; 26: 451-459.
  • 5 Guiot LP, Dejardin LM. Prospective evaluation of minimally invasive plate osteosynthesis in 36 nonarticular tibial fractures in dogs and cats. Vet Surg 2011; 40: 171-182.
  • 6 Uhthoff HK, Poitras P, Backman DS. Internal plate fixation of fractures: short history and recent developments. J Orthop Sci 2006; 11: 118-126.
  • 7 Goodship AE, Watkins PE, Rigby HS. et al. The role of fixator frame stiffness in the control of fracture healing. An experimental study. J Biomech 1993; 26: 1027-1035.
  • 8 Goodship AE, Cunningham JL, Kenwright J. Strain rate and timing of stimulation in mechanical modulation of fracture healing. Clin Orthop Relat Res 1998; S105-115.
  • 9 Johnson AL, Houlton JEF, Vannini R. AO Principles of Fracture Management in the Dog and Cat. Davos: THIEME; 2005
  • 10 Goh CS, Santoni BG, Puttlitz CM. et al. Comparison of the mechanical behaviors of semicontoured, locking plate-rod fixation and anatomically contoured, conventional plate-rod fixation applied to experimentally induced gap fractures in canine femora. Am J Vet Res 2009; 70: 23-29.
  • 11 Johnson AL, Smith CW, Schaeffer DJ. Fragment reconstruction and bone plate fixation versus bridging plate fixation for treating highly comminuted femoral fractures in dogs: 35 cases (1987-1997). J Am Vet Med Assoc 1998; 213: 1157-1161.
  • 12 Pozzi A, Lewis D. Surgical approaches for minimally invasive plate osteosynthesis in dogs. Vet Comp Orthop Traumatol 2009; 22: 316-320.
  • 13 Hudson CC, Pozzi A, Lewis DD. Minimally invasive plate osteosynthesis: applications and techniques in dogs and cats. Vet Comp Orthop Traumatol 2009; 22: 175-182.
  • 14 Guiot L, Guillour P, Dejardin L. Minimally invasive plate osteosynthesis for the treatment of antebrachial fractures in dogs. Proceedings of the European College of Veterinary Surgeons 21st Annual Scientific Meeting [CD]. 2012. July 5-7 Barcelona, Spain.:
  • 15 Witsberger TH, Hulse DA, Kerwin SC. et al. Minimally invasive application of a radial plate following placement of an ulnar rod in treating antebrachial fractures. Technique and case series. Vet Comp Orthop Traumatol 2010; 23: 459-467.
  • 16 Farouk O, Krettek C, Miclau T. et al. Minimally invasive plate osteosynthesis: does percutaneous plating disrupt femoral blood supply less than the traditional technique?. J Orthop Trauma 1999; 13: 401-406.
  • 17 Garofalo S, Pozzi A. The Effect of Minimally Invasive Plating Osteosynthesis and Open Plating Techniques on the Extraosseous Blood Supply of the Canine Radius. Proceedings of the Veterinary Orthopedic Society 38th Annual Conference. 2011. March 5-12 Snowmass, Colorado, USA: Vet Comp Orthop Traumatol 2011. 24 A10.
  • 18 Ochman S, Doht S, Paletta J. et al. Comparison between locking and non-locking plates for fixation of metacarpal fractures in an animal model. J Hand Surg 2010; 35: 597-603.
  • 19 Cheal EJ, Mansmann KA, DiGioia 3rd AM. et al. Role of interfragmentary strain in fracture healing: ovine model of a healing osteotomy. J Orthop Res 1991; 9: 131-142.
  • 20 Jain R, Podworny N, Hupel TM. et al. Influence of plate design on cortical bone perfusion and fracture healing in canine segmental tibial fractures. J Orthop Trauma 1999; 13: 178-186.
  • 21 Gautier E, Sommer C. Guidelines for the clinical application of the LCP. Injury 2003; 34 Supplement 2 63-76.
  • 22 Shahar R, Banks-Sills L, Eliasy R. Stress and strain distribution in the intact canine femur: finite element analysis. Med Eng Phys 2003; 25: 387-395.
  • 23 Sumner DR, Turner TM, Galante JO. Symmetry of the canine femur: implications for experimental sample size requirements. J Orthop Res 1988; 6: 758-765.
  • 24 Johnson KA, Muir P, Nicoll RG. et al. Asymmetric adaptive modeling of central tarsal bones in racing greyhounds. Bone 2000; 27: 257-263.
  • 25 Johnson KA, Skinner GA, Muir P. Site-specific adaptive remodeling of Greyhound metacarpal cortical bone subjected to asymmetrical cyclic loading. Am J Vet Res 2001; 62: 787-793.
  • 26 Veterinary Instrumentation. Veterinary Instrumentation Catalogue - AO/ASIF type screws. Sheffield, UK: Kinspeed [page on internet]; [cited on 2012 April 14]. Available from: http://www.veterinary-instrumentation.co.uk/product.php?productid=3469cat=488page=1) 2012
  • 27 Synthes Veterinary Synthes - eCatalog International [page on the internet]. Basel, Switzerland: dePuy Synthes; [cited on 2012 April 14]. Available from: https://catalog.synthes.com/getsys.ch?catalogId=VETchapterId=VET_02systemId=S_VET_0201.001