Nuklearmedizin 1980; 19(01): 19-21
DOI: 10.1055/s-0037-1620925
Originalarbeiten - Original Articles
Schattauer GmbH

Placental Localisation with 99mTc-Labelled Red Blood Cells

Lokalisierung der Plazenta mit 99mTc-markierten Erythrozyten
P. M. Singh
1   From the Departments of Obstetrics & Gynaecology and Biophysics, Postgraduate Institute of Medical Education and Research, Chandigarh, India
,
M. M. Rehani
1   From the Departments of Obstetrics & Gynaecology and Biophysics, Postgraduate Institute of Medical Education and Research, Chandigarh, India
,
P. K. Devi
1   From the Departments of Obstetrics & Gynaecology and Biophysics, Postgraduate Institute of Medical Education and Research, Chandigarh, India
› Author Affiliations
Further Information

Publication History

Received: 20 May 1979

Publication Date:
09 January 2018 (online)

The accuracy of placental localisation by radioisotopic scanning using 99mTc-labelled red blood cells has been estimated in 20 patients. The results have been correlated with the findings at delivery by direct and indirect methods. The accuracy of results regarding upper and lower segment insertion of the placenta was 90 % in the present study.

Die Genauigkeit der Lokalisierung der Plazenta mittels 99mTc-markierten Erythrozyten und Szintigraphie wurde bei 20 Patienten bestimmt. Die Ergebnisse wurden mit jenen direkten und indirekten Methoden bei der Geburt verglichen. Die Genauigkeit der Diagnose einer Insertion der Plazenta im oberen und unteren Segment betrug in dieser Untersuchung 90%.

 
  • References

  • 1 Browne JC, Veall NAJ. A method of localising the placenta in the intact human uterus by means of radioactive sodium. J. Obst. Gynec. Brit. Emp 57: 566 1950; .
  • 2 Hibbard BM. Placental localisation using radio-iodinated serum albumin (RISA). J. Obst. Gynec. Brit. Cwlth 68: 481 1961; .
  • 3 Jacoby H, Arnot RN, Jeyasingh K. et al. Placental localisation using Technetium99“1 labelled albumin. Obst. Gynec 33: 358 1969; .
  • 4 Johnson PM, Chao S, Goodwin PN. Initial evaluation of Indium“3m as an agent for placental blood pool imaging. Radiology 92: 625 1969; .
  • 5 Laakso A, Raurama L. Placental localisation by the gamma camera and doppler flowmeter. Acta Obst. Gynec. Scand 50: 171 1971; .
  • 6 Larson SM, Nelp WB. Visualisation of placenta by radioisotopic scanning using 99mTc-labelled albumin: Am. J. Obst. Gynec 93: 950 1965; .
  • 7 Nelp WB, Larson SM. Diagnosis of placenta praevia by photoscanning with albumin labelled with Technetium99"1. J. Amer. med. Ass 200: 148 1967; .
  • 8 Paul JD, Gahres EE, Albert SN, Terrel WD, Dodek SM. Placental localisation using Cr5l-tagged erythrocytes. Obst. Gynec 21: 33 1963; .
  • 9 Sharf M, Oettinger M, Diengott D, Spindel A. Blood pool imaging of the placenta with short-lived isotopes. Obst. Gynec 38: 217 1971; .