Vet Comp Orthop Traumatol 1999; 12(02): 97-101
DOI: 10.1055/s-0038-1632472
Case Report
Schattauer GmbH

Revision of Aseptic Loosening of the Femora] Implant in a Dog Using Cable Cerclage

L. Lauren Blaeser
1   From the Department of Small Animal Clinical Sciences, College of Veterinary Medicine, Michigan State University, East Lansing, Michigan
,
A. R. Cross
2   Department of Small Animal Clinical Sciences, College of Veterinary Medicine, University of Florida, Gainesville, Florida
,
O. I. Lanz
3   Department of Small Animal Clinical Sciences, Virginia-Maryland Regional College of Veterinary Medicine, Blacksburg, Virginia, USA
› Author Affiliations
Further Information

Publication History

Received 01 November 1998

Accepted 02 November 1998

Publication Date:
08 February 2018 (online)

Summary

Aseptic loosening of the femoral implant (ALFI) has been reported in 7.2% of total hip arthroplasty procedures in the dog. In this case report, ALFI was diagnosed in a nine year old male German Shepherd, seven years after the initial cemented total hip arthroplasty was performed. The revision of the ALFI was performed using a longitudinal osteotomy to extract the polymethylmethacrylate and the titanium femoral prosthesis was replaced with a cobalt chromium model. The osteotomy and an iatrogenic femoral fracture were repaired using four 1.3 mm cables. Postoperative radiographs revealed satisfactory alignment, reduction of the osteotomy and adequate positioning of the femoral prosthesis.

Case report describing the revision of aseptic loosening of the femoral implant seven years after the initial total hip arthroplasty was performed. The revision utilized four 1.3 mm cable cerclage.

 
  • REFERENCES

  • 1 Berry DJ, Muller ME. Chevron osteotomy and single wire reattachment of the greater trochanter in primary and revision total hip arthroplasty. Clin orthop 1993; 294: 155-61.
  • 2 Blacha J, Kozak J, Bednarek A. Utrasonic technique for removing bone cement in total hip revision arthroplasty. Chir Narzadow Ruchu Ortop Pol 1995; 60 (02) 107-10.
  • 3 Blass CE, Piermattei DL, Withrow SJ, Scott RJ. Static and dynamic cerclage wire analysis. Vet Surg 1986; 15 (02) 181-4.
  • 4 Edwards MR, Egger EL, Schwartz PD. Aseptic loosening of the femoral implant after cemented total hip arthroplasty in dogs: 11 cases in 10 dogs (1991-1995). JAVMA 1997; 211 (05) 580-6.
  • 5 Echenroder HC, Krackow MD. Late onset femoral stress fracture associated with extruded cement following hip arthroplasty. Clin Orthop 1988; 236: 210-3.
  • 6 Herzwurm PJ, Walsh J, Pettine KA, Eber FR. Prophylactic cerclage: a method of preventing femur fracture in uncemented total hip arthroplasty. Orthopedics 1992; 15 (02) 143-6.
  • 7 Klein AH, Rubash HE. Femoral windows in revision total hip arthroplasty. Clin Orthop 1993; June (291) 164-70.
  • 8 Lange DN, Rochat MC, Bartels KE, Payton ME, Hoffman RJ. Schafer StA, Dickey DT. Comparison of carbon dioxide laser modalities for removal of polymethylmethacrylate cement. Vet Comp Orthop Traumatol 1997; 10: 27-32.
  • 9 Lie A, OÕConnor DO, Harris WH. Comparison of cerclage techniques using a hose clamp versus monofilament cerclage wire or cable. J Arthroplasty 1997; 12 (07) 772-6.
  • 10 Newton CD, Hohn RB. Fracture nonunion resulting from cerclage appliances. JAVMA 1974; 164 (05) 503-8.
  • 11 Olmstead ML. The canine cemented modular total hip prosthesis. JAAHA 1995; 31: 109-24.
  • 12 Olmstead ML, Hohn RB. Turner TM. A five-year study of 221 total hip replacements in the dog. JAVMA 1983; 183 (02) 191-4.
  • 13 Piermatte DL. An atlas of surgical approaches to the bones and joints of the dog and cat. Philadelphia, PA: WB Saunders Co;; 1993: 246.
  • 14 Row SC. Mechanical characteristics and comparisons of cerclage wires: Introduction of the double-wrap and loop/twist tying methods. Vet Surg 1997; 26: 310-6.
  • 15 Sherk HH, Lane G, Rhodes A, Black J. Carbon dioxide laser removal of polymethylmethacrylate. Clin Orthop 1995; 310: 67-71.
  • 16 Schmotzer H, Tchejeyan GH. Dall DM. Surgical management of intra- and postoperative fractures of the femur about the tip of the stem in total hip arthroplasty. J Arthroplasty 1996; 11 (06) 709-17.
  • 17 Turner TM, Urban RM, Sumner DR. Galante JO. Revision without cement of aseptically loose cemented total hip prosthesis. J Bone Joint Surg 1993; 75 (06) 845-61.
  • 18 Wagner M, Knorr Held F, Hohmann D. Measuring stability of wire cerclage in femoral fractures when performing total hip replacement. In vitro study on a standardized bone model. Arch Orthop Trauma Surg 1996; 115 (01) 33-7.